Effect of current density on groundwater arsenite removal performance using air cathode electrocoagulation

被引:0
|
作者
Yanxiao Si
Fang Zhang
Chen Hong
Guanghe Li
Haichuan Zhang
Dun Liu
机构
[1] Tsinghua University,School of Environment and State Key Joint Laboratory of Environment Simulation and Pollution Control
[2] Sinopec Petroleum Exploration and Production Research Institute,Surface Engineering Division
[3] University of Science and Technology Beijing,School of Energy and Environmental Engineering
关键词
Electrocoagulation; Air cathode; Arsenic; Current density; Energy consumption;
D O I
暂无
中图分类号
学科分类号
摘要
Naturally occurring arsenic enrichment in groundwater poses a huge threat to human health. Air cathode electrocoagulation (ACEC) has recently been proposed to enhance As(III) oxidation and lower energy consumption. In this study, ACEC, EC/O2 and EC/N2 were evaluated with different current densities from 1 to 8 mA/cm2 to investigate the effect on As(III) removal in different redox environments. Current density had no appreciable effect on arsenic removal efficiency given the same charge in ACEC because the concentration ratio of Fe/H2O2 under different current densities remained stable. However, in EC/O2 and EC/N2, As(III) removal was inhibited at higher current densities (4–8 mA/cm2), likely because more Fe(II) competed with As(III) for the oxidant, leading to less effective oxidation of As(III). In all EC systems, the ·OH units generated per power consumption reached the highest value at the lowest current density. Compared with other EC systems, the ACEC system showed lower energy consumption at all current densities due to the low energy consumption of the electrode reaction and more free radical generation. A lower current density saved more energy at the expense of time, showing the trade-off relationship between energy consumption and removal time. The operation costs for As(III) removal under optimal conditions were calculated as 0.028 $/m3 for ACEC, 0.030 $/m3 for EC/O2, and 0.085 $/m3 for EC/N2
引用
收藏
相关论文
共 50 条
  • [1] Effect of current density on groundwater arsenite removal performance using air cathode electrocoagulation
    Si, Yanxiao
    Zhang, Fang
    Hong, Chen
    Li, Guanghe
    Zhang, Haichuan
    Liu, Dun
    FRONTIERS OF ENVIRONMENTAL SCIENCE & ENGINEERING, 2021, 15 (06)
  • [2] Effect of current density on groundwater arsenite removal performance using air cathode electrocoagulation
    Yanxiao Si
    Fang Zhang
    Chen Hong
    Guanghe Li
    Haichuan Zhang
    Dun Liu
    Frontiers of Environmental Science & Engineering, 2021, 15 (06) : 12 - 20
  • [3] Energy-Efficient Oxidation and Removal of Arsenite from Groundwater Using Air-Cathode Iron Electrocoagulation
    Si, Yanxiao
    Li, Guanghe
    Zhang, Fang
    ENVIRONMENTAL SCIENCE & TECHNOLOGY LETTERS, 2017, 4 (02): : 71 - 75
  • [4] Tradeoff between groundwater arsenite removal efficiency and current production in the self-powered air cathode electrocoagulation with different oxygen reduction pathways
    Si, Yanxiao
    Li, Guanghe
    Wu, Yue
    Zhang, Hao
    Yuan, Ying
    Zhang, Haichuan
    Liu, Bo
    Zhang, Fang
    JOURNAL OF HAZARDOUS MATERIALS, 2018, 357 : 138 - 145
  • [5] Effect of current density on COD removal efficiency for wastewater using the electrocoagulation process
    Reategui-Romero, Warren
    Morales-Quevedo, Sergio E.
    Huanca-Colos, Karen W.
    Figueroa-Gomez, Noel M.
    King-Santos, Maria E.
    Zaldivar-Alvarez, Walter F.
    Flores-Del Pino, Lisveth, V
    Yuli-Posadas, Ricardo A.
    Bulege-Gutierrez, Wilfredo
    DESALINATION AND WATER TREATMENT, 2020, 184 : 15 - 29
  • [6] Synergistic oxidation and removal of arsenite from groundwater using an energy-efficient advanced electrocoagulation
    Si, Yanxiao
    Li, Guanghe
    Feng, Chen
    Zhang, Fang
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 252
  • [7] Study on electrocoagulation parameters (current density, pH, and electrode distance) for removal of fluoride from groundwater
    Kim, Kyung-Jo
    Baek, Kitae
    Ji, Sangwoo
    Cheong, Youngwook
    Yim, Giljae
    Jang, Am
    ENVIRONMENTAL EARTH SCIENCES, 2016, 75 (01) : 1 - 8
  • [8] Study on electrocoagulation parameters (current density, pH, and electrode distance) for removal of fluoride from groundwater
    Kyung-Jo Kim
    Kitae Baek
    Sangwoo Ji
    Youngwook Cheong
    Giljae Yim
    Am Jang
    Environmental Earth Sciences, 2016, 75
  • [9] Effect of electrode combinations, ph and current density on arsenic removal from drinking water using electrocoagulation
    Dolo, A.L.
    Goel, S.
    Journal of the Institution of Engineers (India): Environmental Engineering Division, 2010, 90 (MARCH): : 21 - 25
  • [10] Arsenite removal from groundwater in a batch electrocoagulation process: Optimization through response surface methodology
    Demirbas, Erhan
    Kobya, Mehmet
    Oncel, Mehmet Salim
    Sik, Emrah
    Goren, Aysegul Yagmur
    SEPARATION SCIENCE AND TECHNOLOGY, 2019, 54 (05) : 775 - 785