7-Amino-4-azaheptyl Grafted onto a Silica Gel as a Sorbent for the On-line Preconcentration and Determination of Iron(III) in Water Samples

被引:0
|
作者
Sandra V. M. de Moraes
Mateus M. Tisott
Caroline D. Milcharek
Jorge L. Brasil
Tania M. H. Costa
Márcia R. Gallas
Edilson V. Benvenutti
Eder C. Lima
机构
[1] Colégio Militar de Porto Alegre,
[2] Universidade Federal do Rio Grande do Sul-Instituto de Física,undefined
来源
Analytical Sciences | 2005年 / 21卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A new sorbent was synthesized by anchoring 7-amino-4-azaheptyltrimetoxisilane, freshly prepared, to silica gel, producing 7-amino-4-azaheptyl anchored silica gel (AAHSG). This material was characterized by infrared spectroscopy (IR), elemental analysis (CHN), and nitrogen adsorption-desorption isotherms. Isotherms of the adsorption of Fe3+, Fe2+ and Cu2+ on AAHSG were recorded, which indicated that Fe3+ presents a higher affinity by the sorbent. Therefore, AAHSG was successfully employed as a sorbent in a simple flow system for the preconcentration of Fe3+ in natural water samples, such as, river water, lagoonwater, springwater, stream water, well water and two water reference materials (NIST-SRM 1640, NIST-SRM 1643d). The obtained preconcentration factor was 82.2, and the detection limit achieved was 5.9 ng ml–1. The recovery of spiked water samples ranged from 95.0–103.1%.
引用
收藏
页码:573 / 577
页数:4
相关论文
共 49 条
  • [1] 7-amino-4-azaheptyl grafted onto a silica gel as a sorbent for the on-line preconcentration and determination of iron(III) in water samples
    de Moraes, SVM
    Tisott, MM
    Milcharek, CD
    Brasil, JL
    Costa, TMH
    Gallas, MR
    Benvenutti, EV
    Lima, EC
    ANALYTICAL SCIENCES, 2005, 21 (05) : 573 - 577
  • [2] 7-Amino-4-azaheptyl grafted onto a silica gel as a sorbent for the on-line preconcentration and determination of iron(III) in water samples
    Colégio Militar de Porto Alegre, Av. Jose Bonifacio, 363, 90040-130, Porto Alegre, RS, Brazil
    不详
    1600, 573-577 (May 2005):
  • [3] Simultaneous preconcentration and speciation of iron(II) and iron(III) in water samples by 2-mercaptobenzimidazole-silica gel sorbent and flow injection analysis system
    Bagheri, H
    Gholami, A
    Najafi, A
    ANALYTICA CHIMICA ACTA, 2000, 424 (02) : 233 - 242
  • [4] Iminodiacetic acid-containing polymer brushes grafted onto silica gel for preconcentration and determination of copper(II) in environmental samples
    Panahi, Homayon Ahmad
    Mehmandost, Nasrin
    Moniri, Elham
    Galaev, Igor Yu
    JOURNAL OF APPLIED POLYMER SCIENCE, 2012, 126 (02) : 480 - 489
  • [5] On-line Determination of Zinc in Water and Biological Samples after Its Preconcentration onto Zincon Anchored Polyurethane Foam
    Azeem, Sami M. Abdel
    Hanafi, Hassan A.
    El-Shahat, M. F.
    ANALYTICAL SCIENCES, 2015, 31 (05) : 391 - 397
  • [6] On-line Determination of Zinc in Water and Biological Samples after Its Preconcentration onto Zincon Anchored Polyurethane Foam
    Sami M. Abdel Azeem
    Hassan A. Hanafi
    M. F. El-Shahat
    Analytical Sciences, 2015, 31 : 391 - 397
  • [7] Determination of lead, iron and nickel in water and vegetable samples after preconcentration with Aspergillus niger loaded on silica gel
    Baytak, Sitki
    Kocyigit, Abdurrahim
    Turker, Ali Rehber
    CLEAN-SOIL AIR WATER, 2007, 35 (06) : 607 - 611
  • [8] Determination of cadmium in river water samples by flame AAS after on-line preconcentration in mini-column packed with 2-aminothiazole-modified silica gel
    Alcântara I.L.
    Roldan P.S.
    Castro G.R.
    Moraes F.V.
    Silva F.A.
    Padilha C.C.F.
    Oliveira J.D.
    Padilha P.M.
    Analytical Sciences, 2004, 20 (7) : 1029 - 1032
  • [9] Determination of cadmium in river water samples by flame AAS after on-line preconcentration in mini-column packed with 2-aminothiazole-modified silica gel
    Alcântara, TL
    Roldan, PS
    Castro, GR
    Moraes, FV
    Silva, FA
    Padilha, CCF
    Oliveira, JA
    Padilha, PM
    ANALYTICAL SCIENCES, 2004, 20 (07) : 1029 - 1032
  • [10] Cr(III) and Cr(VI) on-line preconcentration and high-performance flow flame emission spectrometric determination in water samples
    Posta, J
    Gaspar, A
    Toth, R
    Ombodi, L
    MICROCHEMICAL JOURNAL, 1996, 54 (03) : 195 - 203