Estimation of aquifer hydraulic parameters from geoelectrical method—a case study of Yenagoa and environs, Southern Nigeria

被引:0
|
作者
K. S. Okiongbo
P. Mebine
机构
[1] Niger Delta University,Department of Physics, Geophysics Unit
[2] Niger Delta University,Department of Mathematics
来源
关键词
Hydraulic parameters; Dar Zarrouk parameters; Vertical electrical sounding; Aquifer; Yenegoa;
D O I
暂无
中图分类号
学科分类号
摘要
Knowledge of water transmitting properties of an aquifer is crucial for successful groundwater development and management practices in an area. In this study, the determination of aquifer hydraulic characteristics at Yenagoa and environs from Dar Zarrouk parameters was carried out using 14 vertical electrical sounding data (VES) and information from existing boreholes. The Schlumberger electrode configuration was employed for the field data acquisition with a maximum half electrode separation (AB/2) ranging between 100 and 350 m. The VES data were interpreted using 1D inversion technique software (1X1D, Interpex, USA). A maximum of four geoelectric layers were delineated and the aquifer is characterized by loose sand with resistivity ranging from 136.1 to 828.6 Ωm and thickness of 8.3–97.6 m. Using the VES results and water resistivity, porosity was determined using modified Archie’s equation. The hydraulic conductivity (K) values obtained from three reference boreholes were combined with the electrical resistivity obtained from the respective nearby VES stations to determine a diagnostic constant (Kρ). The resulting relation was interpreted with Dar Zarrouk parameters to infer the hydraulic conductivity (K) and transmissivity (T) variations at vertical electrical sounding locations, where K values are unknown. The results indicate that porosity varies between 0.09 and 0.32. The hydraulic conductivities range from 0.8 × 10−4 to 6.6 × 10−4 m/s while the transmissivity values vary between 1.1 × 10−3 and 29.6 × 10−3 m2/s. The high transmissivity values are consistent with the aquifer being unconsolidated with fine–medium–coarse sands.
引用
收藏
页码:6085 / 6093
页数:8
相关论文
共 50 条
  • [1] Estimation of aquifer hydraulic parameters from geoelectrical method-a case study of Yenagoa and environs, Southern Nigeria
    Okiongbo, K. S.
    Mebine, P.
    [J]. ARABIAN JOURNAL OF GEOSCIENCES, 2015, 8 (08) : 6085 - 6093
  • [2] Hydrogeophysical Characterization of Shallow Unconsolidated Alluvial Aquifer in Yenagoa and Environs, Southern Nigeria
    Okiongbo, K. S.
    Akpofure, E.
    [J]. ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2016, 41 (06) : 2261 - 2270
  • [3] Hydrogeophysical Characterization of Shallow Unconsolidated Alluvial Aquifer in Yenagoa and Environs, Southern Nigeria
    K. S. Okiongbo
    E. Akpofure
    [J]. Arabian Journal for Science and Engineering, 2016, 41 : 2261 - 2270
  • [4] Estimation of Aquifer Hydraulic Characteristics from Surface Geoelectrical Methods: Case Study of the Rima Basin, North Western Nigeria
    S. Olatunji
    A. Musa
    [J]. Arabian Journal for Science and Engineering, 2014, 39 : 5475 - 5487
  • [5] Estimation of Aquifer Hydraulic Characteristics from Surface Geoelectrical Methods: Case Study of the Rima Basin, North Western Nigeria
    Olatunji, S.
    Musa, A.
    [J]. ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2014, 39 (07) : 5475 - 5487
  • [6] Hydrogeological framework and estimation of aquifer hydraulic parameters using geoelectrical data: a case study from West Iran
    Tizro, Abduulah Taheri
    Voudouris, Kostantanous S.
    Salehzade, Mortaza
    Mashayekhi, Hassan
    [J]. HYDROGEOLOGY JOURNAL, 2010, 18 (04) : 917 - 929
  • [7] Estimation of hydraulic parameters in a complex porous aquifer system using geoelectrical methods
    Kazakis, N.
    Vargemezis, G.
    Voudouris, K. S.
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2016, 550 : 742 - 750
  • [8] Estimation of hydraulic parameters of an unconfined aquifer by using geoelectrical and pumping test data: a case study of the Mandi Bahauddin District, Pakistan
    Ullah, Faheem
    Su, Li-Jun
    Ullah, Hafeez
    Asghar, Aamir
    [J]. ARABIAN JOURNAL OF GEOSCIENCES, 2020, 13 (12)
  • [9] Estimation of hydraulic parameters of an unconfined aquifer by using geoelectrical and pumping test data: a case study of the Mandi Bahauddin District, Pakistan
    Faheem Ullah
    Li-Jun Su
    Hafeez Ullah
    Aamir Asghar
    [J]. Arabian Journal of Geosciences, 2020, 13
  • [10] Evaluation of aquifer hydraulic characteristics using geoelectrical sounding, pumping and laboratory tests: A case study of Lokoja and Patti Formations, Southern Bida Basin, Nigeria
    Ige, Olusegun Omoniyi
    Obasaju, Daniel Opemipo
    Baiyegunhi, Christopher
    Ogunsanwo, Olufemi
    Baiyegunhi, Temitope Love
    [J]. OPEN GEOSCIENCES, 2018, 10 (01): : 807 - 820