Variability between Hirst-type pollen traps is reduced by resistance-free flow adjustment

被引:0
|
作者
M. M. Triviño
J. M. Maya-Manzano
F. Tummon
B. Clot
Ł. Grewling
C. Schmidt-Weber
J. Buters
机构
[1] Technical University and Helmholtz Center Munich,Center of Allergy and Environment (ZAUM), Member of the German Center for Lung Research (DZL)
[2] University of Cordoba,Agroforestry and Plant Biochemistry, Proteomics and Systems Biology, Department of Biochemistry and Molecular Biology
[3] University of Extremadura,Department of Plant Biology, Ecology and Earth Sciences (Botany Area), Faculty of Sciences
[4] Federal Office of Meteorology and Climatology MeteoSwiss,Laboratory of Aerobiology, Department of Systematic and Environmental Botany, Faculty of Biology
[5] Adam Mickiewicz University,undefined
来源
Aerobiologia | 2023年 / 39卷
关键词
Pollen monitoring; Hirst; Airflow; Resistance-free flowmeters; Sampling variability; Intercomparison;
D O I
暂无
中图分类号
学科分类号
摘要
During an international campaign organized in Munich (Germany) in 2021 to test the performance of automatic pollen traps, we ran four manual Hirst-type pollen traps in parallel. All 4 Hirst-type pollen traps were set and monitored on a weekly basis for the entire campaign to 10 L/min using the same standard hand-held rotameter. Afterwards, a hand-held heat-wire anemometer (easyFlux®) was used additionally to obtain the correct flow without internal resistance. Uncorrected pollen concentrations were 26.5% (hourly data) and 21.0% (daily data) higher than those obtained after correction with the easyFlux®. After mathematical flow correction, the average coefficient of variation between the four Hirst traps was 42.6% and 16.5% (hourly and daily averages, respectively) for birch and 36.8% and 16.8% (hourly and daily averages, respectively) for grasses. When using the correct flow of each pollen trap (i.e. the resistance free anemometer measured flow), for hourly values, the median standard deviation across the traps for the eight pollen types was reduced by 28.2% (p < 0.001) compared to the uncorrected data. For daily values, a significant decrease in the median standard deviation (21.6%) between traps was observed for 7 out of 8 of the pollen types, (p < 0.05 or lower). We therefore recommend continuing to calibrate Hirst-type pollen traps with standard hand-held rotameters to avoid changing the impacting characteristics of the instruments, but simultaneously also measure with resistance-free flow meters to be able to apply flow corrections to the final pollen concentrations reported. This method improved the accuracy of the final results.
引用
收藏
页码:257 / 273
页数:16
相关论文
共 11 条
  • [1] Variability between Hirst-type pollen traps is reduced by resistance-free flow adjustment
    Trivino, M. M.
    Maya-Manzano, J. M.
    Tummon, F.
    Clot, B.
    Grewling, L.
    Schmidt-Weber, C.
    Buters, J.
    AEROBIOLOGIA, 2023, 39 (02) : 257 - 273
  • [2] Correction to: Variability between Hirst-type pollen traps is reduced by resistance-free flow adjustment
    M. M. Triviño
    J. M. Maya-Manzano
    F. Tummon
    B. Clot
    Ł. Grewling
    C. Schmidt-Weber
    J. Buters
    Aerobiologia, 2023, 39 : 389 - 390
  • [3] Variability between Hirst-type pollen traps is reduced by resistance-free flow adjustment (vol 39, pg 257, 2023)
    Trivino, M. M.
    Maya-Manzano, J. M.
    Tummon, F.
    Clot, B.
    Grewling, L.
    Schmidt-Weber, C.
    Buters, J.
    AEROBIOLOGIA, 2023, 39 (03) : 389 - 390
  • [4] Accuracy of a hand-held resistance-free flowmeters for flow adjustments of Hirst-Type pollen traps
    Suarez-Suarez, Mariel
    Maya-Manzano, Jose M. M.
    Clot, Bernard
    Graber, Marie-Jose
    Sallin, Christine
    Tummon, Fiona
    Buters, Jeroen
    AEROBIOLOGIA, 2023, 39 (01) : 143 - 148
  • [5] Accuracy of a hand-held resistance-free flowmeters for flow adjustments of Hirst-Type pollen traps
    Mariel Suarez-Suarez
    Jose M. Maya-Manzano
    Bernard Clot
    Marie-José Graber
    Christine Sallin
    Fiona Tummon
    Jeroen Buters
    Aerobiologia, 2023, 39 : 143 - 148
  • [6] Errors in determining the flow rate of Hirst-type pollen traps
    Jose Oteros
    Jeroen Buters
    Gottfried Laven
    Stefani Röseler
    Reinhard Wachter
    Carsten Schmidt-Weber
    Frieder Hofmann
    Aerobiologia, 2017, 33 : 201 - 210
  • [7] Errors in determining the flow rate of Hirst-type pollen traps
    Oteros, Jose
    Buters, Jeroen
    Laven, Gottfried
    Roeseler, Stefani
    Wachter, Reinhard
    Schmidt-Weber, Carsten
    Hofmann, Frieder
    AEROBIOLOGIA, 2017, 33 (02) : 201 - 210
  • [8] Frequency and distribution of insect pollinated pollen in air samples of Hirst-type volumetric pollen and spore traps in Austria from 2008 to 2017
    Bastl, Katharina
    Bastl, Maximilian
    Dirr, Lukas
    Berger, Markus
    Berger, Uwe
    GRANA, 2020, 59 (01) : 58 - 70
  • [9] Towards European automatic bioaerosol monitoring: Comparison of 9 au-tomatic pollen observational instruments with classic Hirst-type traps
    Maya-Manzano, Jose M.
    Tummon, Fiona
    Abt, Reto
    Allan, Nathan
    Bunderson, Landon
    Clot, Bernard
    Crouzy, Benoit
    Daunys, Gintautas
    Erb, Sophie
    Gonzalez-Alonso, Monica
    Graf, Elias
    Grewling, Lukasz
    Haus, Joerg
    Kadantsev, Evgeny
    Kawashima, Shigeto
    Martinez-Bracero, Moises
    Matavulj, Predrag
    Mills, Sophie
    Niederberger, Erny
    Lieberherr, Gian
    Lucas, Richard W.
    O'Connor, David J.
    Oteros, Jose
    Palamarchuk, Julia
    Pope, Francis D.
    Rojo, Jesus
    Sauliene, Ingrida
    Schaefer, Stefan
    Schmidt-Weber, Carsten B.
    Schnitzler, Martin
    Sikoparija, Branko
    Skjoth, Carsten A.
    Sofiev, Mikhail
    Stemmler, Tom
    Trivino, Marina
    Zeder, Yanick
    Buters, Jeroen
    SCIENCE OF THE TOTAL ENVIRONMENT, 2023, 866
  • [10] Analysis of airborne pollen time series originating from Hirst-type volumetric samplers—comparison between mobile sampling head oriented toward wind direction and fixed sampling head with two-layered inlet
    Gordan Mimić
    Branko Šikoparija
    Aerobiologia, 2021, 37 : 321 - 331