Thermodynamic performance of a hybrid air cycle refrigeration system using a desiccant rotor

被引:0
|
作者
Kyudae Hwang
Chan Ho Song
Sung Ki Kim
Kiyoshi Saito
Sunao Kawai
机构
[1] Yuhan University,Department of Industrial Japanese
[2] Korea Institute of Machinery and Material,Mechanical Solution Lab., Visual Display Division
[3] Samsung Electronics,Department of Applied Mechanics and Aerospace Engineering
[4] Waseda University,undefined
来源
Heat and Mass Transfer | 2013年 / 49卷
关键词
Heat Exchanger; Humidity Ratio; Brayton Cycle; Desiccant Wheel; Alternative Refrigerant;
D O I
暂无
中图分类号
学科分类号
摘要
Due to the concern on global warming, the demand for a system using natural refrigerant is increasing and many researches have been devoted to develop systems with natural refrigerants. Among natural refrigerant systems, an air cycle system has emerged as one of alternatives of Freon gas system due to environmentally friendly feature in spite of the inherent low efficiency. To overcome the technical barrier, this study proposed combination of multiple systems as a hybrid cycle to achieve higher efficiency of an air cycle system. The hybrid air cycle adopts a humidity control units such as an adsorber and a desorber to obtain the cooling effect from latent heat as well as sensible heat. To investigate the efficacy of the hybrid air cycle, the cooling performance of a hybrid air cycle is investigated analytically and experimentally. From the simulation result, it is found that COP of the hybrid air cycle is two times higher than that of the conventional air cycle. The experiments are conducted on the performance of the desiccant system according to the rotation speed in the system and displayed the feasibility of the key element in the hybrid air cycle system. From the results, it is shown that the system efficiency can be enhanced by utilization of the exhausted heat through the ambient heat exchanger with advantage of controlling the humidity by the desiccant rotor.
引用
收藏
页码:359 / 367
页数:8
相关论文
共 50 条
  • [1] Thermodynamic performance of a hybrid air cycle refrigeration system using a desiccant rotor
    Hwang, Kyudae
    Song, Chan Ho
    Kim, Sung Ki
    Saito, Kiyoshi
    Kawai, Sunao
    HEAT AND MASS TRANSFER, 2013, 49 (03) : 359 - 367
  • [2] Thermodynamic analysis of the actual air cycle refrigeration system
    Liu Shengjun
    Zhang Zhenying
    Tian Lili
    ENGINEERING AND RISK MANAGEMENT, 2011, 1 : 112 - 116
  • [3] Comparison of two methods of improving dehumidification in air conditioning systems: hybrid system (refrigeration cycle - rotary desiccant) and heat exchanger cycle
    Sayegh, Marderos Aar
    Hammad, Mohammad
    Faraa, Zakwan
    IMPACT OF INTEGRATED CLEAN ENERGY ON THE FUTURE OF THE MEDITERRANEAN ENVIRONMENT, 2011, 6 : 759 - 768
  • [4] Performance analysis of a hybrid desiccant air conditioning system
    Jia, Chun-Xia
    Dai, Yan-Jun
    Wu, Jing-Yi
    Zhong, Jin-Hua
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2005, 26 (06): : 921 - 923
  • [5] Thermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning
    Zhang, Zhenying
    Liu, Shengjun
    Tian, Lili
    ENGINEERING AND RISK MANAGEMENT, 2011, 1 : 16 - 22
  • [6] Thermodynamic Analysis a Novel Wave Rotor Refrigeration Cycle
    Zhao, Jiaquan
    Hu, Dapeng
    Liu, Peiqi
    Liu, Fengxia
    Gao, Jinji
    ENERGY AND POWER TECHNOLOGY, PTS 1 AND 2, 2013, 805-806 : 537 - +
  • [7] Study on the Hybrid Liquid Desiccant Evaporative Cooling Air-Conditioning Refrigeration Circulation System
    Liu, Xiong
    ELECTRICAL POWER & ENERGY SYSTEMS, PTS 1 AND 2, 2012, 516-517 : 1250 - 1256
  • [8] Performance of hybrid refrigeration system using ammonia
    Lychnos, G.
    Tamainot-Telto, Z.
    APPLIED THERMAL ENGINEERING, 2014, 62 (02) : 560 - 565
  • [9] Performance of hybrid refrigeration system using ammonia
    Lychnos, G. (G.Lychnos@warwick.ac.uk), 1600, Elsevier Ltd (61):
  • [10] Performance Analysis of a Desiccant Rotor for Rotational Period in a Desiccant Cooling System
    Pi, Chang Hun
    Ha Kang, Byung
    Chang, Young Soo
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2012, 36 (05) : 523 - 531