How accurately can QT interval be measured in newborn infants?

被引:0
|
作者
Katya De Groote
Bert Suys
An Deleeck
Daniël De Wolf
Dirk Matthys
Bart Van Overmeire
机构
[1] Antwerp University Hospital,Divisions of Neonatology and Paediatric Cardiology
[2] Ghent University Hospital,Division of Paediatric Cardiology
[3] Ghent University Hospital,Department of Paediatric Cardiology
来源
关键词
Heart rate corrected QT interval; Neonates; Reproducibility;
D O I
暂无
中图分类号
学科分类号
摘要
We determined inter- and intra-observer variability of measurements of QT and heart rate corrected QT (QTc) interval in newborn infants. In 55 newborns, a standard 12-lead electrocardiogram (ECG) with rhythm strip was analysed independently by three observers. QT and the preceding RR interval were measured in three different beats. The QTc interval was calculated using the Bazett formula (QTc = QT/√RR). Observers repeated their measurements after the recruitment period blinded for their first reading. Inter- and intra-observer variability were determined using the Bland and Altman method. In total, 59 ECGs were recorded. Due to artifacts, six had to be excluded. A marked inter-observer variability was observed in the measurement of the QT and QTc interval. Important intra-observer variability was denoted, with differences up to 80 ms for QTc. Conclusion:mainly due to high heart rates, important inter- and intra-observer variability hampers a correct interpretation of the QT interval in newborn infants. We suggest not to rely on one single measurement and to apply different methods of measurement and a margin of safety when interpreting QT and heart rate corrected QT intervals in these age groups for making therapeutic decisions.
引用
收藏
页码:875 / 879
页数:4
相关论文
共 50 条
  • [1] How accurately can QT interval be measured in newborn infants?
    De Groote, K
    Suys, B
    Deleeck, A
    De Wolf, D
    Matthys, D
    Van Overmeire, B
    [J]. EUROPEAN JOURNAL OF PEDIATRICS, 2003, 162 (12) : 875 - 879
  • [2] HOW ACCURATELY CAN TEMPERATURE BY MEASURED
    GRAY, WT
    FINCH, DI
    [J]. PHYSICS TODAY, 1971, 24 (09) : 32 - &
  • [3] How Accurately Can We Determine the Coefficients: Case of Interval Uncertainty
    Cerny, Michal
    Kreinovich, Vladik
    [J]. FUZZY TECHNIQUES: THEORY AND APPLICATIONS, 2019, 1000 : 779 - 787
  • [4] Can lignin be accurately measured?
    Hatfield, R
    Fukushima, RS
    [J]. CROP SCIENCE, 2005, 45 (03) : 832 - 839
  • [5] How Accurately Can Lens Volume Be Measured With Magnetic Resonance Imaging?
    Wendt, M.
    Bockhorst, K. H.
    He, L.
    Glasser, A.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [6] Dry laser cleaning threshold fluence - How can it be measured accurately?
    Fernandes, A
    Kane, D
    [J]. SECOND INTERNATIONAL SYMPOSIUM ON LASER PRECISION MICROFABRICATION, 2002, 4426 : 290 - 295
  • [7] HOW ACCURATELY CAN FLOW BE MEASURED IN NUCLEUS-NUCLEUS COLLISIONS
    SULLIVAN, JP
    PETER, J
    [J]. NUCLEAR PHYSICS A, 1992, 540 (1-2) : 275 - 290
  • [9] QT INTERVAL IN ABORTED SIDS INFANTS
    HADDAD, GG
    EPSTEIN, MAF
    EPSTEIN, RA
    MAZZA, NM
    MELLINS, RB
    [J]. PEDIATRIC RESEARCH, 1978, 12 (04) : 526 - 526
  • [10] How to measure a QT interval
    Waddell-Smith, Kathryn
    Gow, Robert M.
    Skinner, Jonathan R.
    [J]. MEDICAL JOURNAL OF AUSTRALIA, 2017, 207 (03) : 107 - +