Influence of AgCl Precipitates on the Precipitation Titration of Sodium Chloride by Constant-Current Coulometry

被引:0
|
作者
Toshiaki Asakai
Hisao Hara
Mariko Murayama
Tatsuhiko Tanaka
机构
[1] National Institute of Technology and Evaluation,Faculty of Engineering
[2] Tokyo University of Science,undefined
来源
Analytical Sciences | 2006年 / 22卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The precipitation titration of sodium chloride with electrogenerated silver ion was studied. The production of a precipitate of silver chloride had a significant effect on the titration results because the precipitate involved unreacted chloride or unreacted silver ion. The accuracy of the method was investigated by changing the introduction time of a sodium chloride solution to the coulometric cell during the process of electrolysis, and examining the dependency on the sample size. The accuracy of the measurement of the precipitation titration is discussed.
引用
收藏
页码:1121 / 1124
页数:3
相关论文
共 47 条
  • [1] Influence of AgCl precipitates on the precipitation titration of sodium chloride by constant-current coulometry
    Asakai, Toshiaki
    Hara, Hisao
    Murayama, Mariko
    Tanaka, Tatsuhiko
    ANALYTICAL SCIENCES, 2006, 22 (08) : 1121 - 1124
  • [2] Constant-Current Coulometry and Ion Chromatography Bromide Determination to Characterize the Purity of the Potassium Chloride
    Borges, Paulo P.
    Sobral, Sidney P.
    da Silva, Lilian
    Araujo, Thiago O.
    Silva, Renata S.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2011, 22 (10) : 1931 - 1938
  • [3] Determination of the purity of potassium iodate by constant-current coulometry
    L. Ma
    Accreditation and Quality Assurance, 2002, 7 : 163 - 167
  • [4] Determination of the purity of potassium iodate by constant-current coulometry
    Ma, LD
    ACCREDITATION AND QUALITY ASSURANCE, 2002, 7 (04) : 163 - 167
  • [5] A METHOD OF END-POINT LOCATION IN CONSTANT-CURRENT COULOMETRY
    ALEXANDER, WA
    BARCLAY, DJ
    MCMILLAN, A
    ANALYST, 1965, 90 (1073) : 504 - +
  • [6] SIMPLE METHOD FOR THE DETERMINATION OF LOW CATION-EXCHANGE CAPACITY AND THE TITRATION OF CATION EXCHANGERS BY CONSTANT-CURRENT COULOMETRY
    HAJOS, P
    INCZEDY, J
    JOURNAL OF CHROMATOGRAPHY, 1980, 201 (NOV): : 193 - 197
  • [7] COUPLING OF THERMOMETRIC TITRIMETRY AND CONSTANT-CURRENT COULOMETRY - STUDY AND APPLICATIONS
    BOUDEVILLE, P
    BURGOT, JL
    JOURNAL OF THERMAL ANALYSIS, 1985, 30 (01): : 5 - 16
  • [8] INTEGRATED-CIRCUIT POWER SOURCE FOR CONSTANT-CURRENT COULOMETRY
    MUHA, GM
    JOURNAL OF CHEMICAL EDUCATION, 1976, 53 (07) : 465 - 466
  • [9] Constant-current coulometric titration of hydrochloric acid
    Bentonville High School, 402 Tiger Blvd., Bentonville, AR 72712, United States
    不详
    J Chem Educ, 7 (679-683):
  • [10] Constant-current coulometric titration of hydrochloric acid
    Swim, J
    Earps, E
    Reed, LM
    Paul, D
    JOURNAL OF CHEMICAL EDUCATION, 1996, 73 (07) : 679 - 683