Ascending aortic aneurysm in a patient with an aortic Starr-Edwards ball valve prosthesis implanted 39 years previously

被引:1
|
作者
Nishigawa K. [1 ]
Totsugawa T. [1 ]
Yoshitaka H. [1 ]
Tsushima Y. [1 ]
Kuinose M. [1 ]
Chikazawa G. [1 ]
机构
[1] Department of Cardiovascular Surgery, Sakakibara Heart Institute of Okayama, Okayama 700-0823, 2-1-10 Marunouchi, Kita-ku
关键词
Ascending aortic aneurysm; Reoperation; Starr-Edwards ball valve prosthesis;
D O I
10.1007/s11748-009-0504-3
中图分类号
学科分类号
摘要
A 53-year-old man who had undergone aortic valve replacement with a Starr-Edwards ball valve prosthesis 39 years previously was admitted to our hospital under the diagnosis of ascending aortic aneurysm. Operative fi ndings revealed that the ball valve was functioning normally. The markedly dilated ascending aorta was replaced with a 30-mm prosthetic vascular graft, and the ball valve was replaced with a19-mm bileafl et valve prosthesis. The patient's postoperative course was uneventful, and he was discharged from our hospital 19 days after surgery. Dilatation of the ascending aorta in this case might have been caused by the poststenotic dilatation mechanism, which seems to be one of the long-term complications of Starr-Edwards ball valve implantation. © 2010 The Japanese Association for Thoracic Surgery.
引用
收藏
页码:138 / 140
页数:2
相关论文
共 50 条
  • [1] Use of the Bentall method for replacement of an aortic Starr-Edwards ball valve prosthesis implanted 32 years previously
    Yotsumoto D.
    Iguro Y.
    Ueno T.
    Matsumoto K.
    Sakata R.
    [J]. General Thoracic and Cardiovascular Surgery, 2007, 55 (8) : 331 - 334
  • [2] Ascending aortic aneurysm repair 44 years after Starr-Edwards caged-ball aortic valve replacement
    Hatton, Gabrielle E.
    Tanaka, Akiko
    Estrera, Anthony L.
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2018, 54 (05) : 962 - 963
  • [3] Fatal embolization of ball portion of Starr-Edwards aortic valve prosthesis
    Reddy, KK
    Anders, KH
    Sathyavagiswaran, L
    [J]. JOURNAL OF FORENSIC SCIENCES, 1998, 43 (01) : 225 - 227
  • [4] Replacement of an aortic Starr-Edwards ball valve prosthesis 28 years after implantation
    Tayama, K
    Akashi, H
    Tayama, E
    Fukunaga, S
    Kawara, T
    Kosuga, K
    Aoyagi, S
    [J]. CIRCULATION JOURNAL, 2004, 68 (05) : 507 - 508
  • [5] FATAL OBSTRUCTION OF AORTIC ROOT BY STARR-EDWARDS AORTIC BALL-VALVE PROSTHESIS
    NAJAFI, H
    DEWALL, RA
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1966, 51 (02): : 180 - &
  • [6] Patient with a Starr-Edwards Prosthesis in the Aortic Position for 40 Years
    Miranda, Matheus
    do Nascimento, Luciene
    Haddad, Michel Raineri
    Haddad, William Teixeira, Jr.
    Haddad, William Teixeira
    Buffolo, Enio
    [J]. JOURNAL OF HEART VALVE DISEASE, 2013, 22 (05): : 648 - 650
  • [7] Starr-Edwards valves at the aortic and mitral positions implanted for 39 years
    Misawa S.-I.
    Aizawa K.
    Kaminishi Y.
    Muraoka A.
    Misawa Y.
    [J]. General Thoracic and Cardiovascular Surgery, 2011, 59 (6) : 433 - 435
  • [8] Bentall procedure 39 years after implantation of a Starr-Edwards Aortic Caged- Ball-Valve Prosthesis
    Jan D Schmitto
    Philipp Ortmann
    Aron F Popov
    Kasim O Coskun
    Hanna Schotola
    Martin Friedrich
    Christoph H Wiese
    Christian Sohns
    Suyog A Mokashi
    Vassilios N Didilis
    Friedrich A Schoendube
    [J]. Journal of Cardiothoracic Surgery, 5
  • [9] Bentall procedure 39 years after implantation of a Starr-Edwards Aortic Caged- Ball-Valve Prosthesis
    Schmitto, Jan D.
    Ortmann, Philipp
    Popov, Aron F.
    Coskun, Kasim O.
    Schotola, Hanna
    Friedrich, Martin
    Wiese, Christoph H.
    Sohns, Christian
    Mokashi, Suyog A.
    Didilis, Vassilios N.
    Schoendube, Friedrich A.
    [J]. JOURNAL OF CARDIOTHORACIC SURGERY, 2010, 5
  • [10] 49 years of normal functioning Starr-Edwards aortic valve prosthesis
    Sabouni, Mouhamed Amr
    Baumeister, Robin H.
    Traverse, Paul
    [J]. OXFORD MEDICAL CASE REPORTS, 2020, (02): : 39 - 42