Monte Carlo simulations of electron beams collimated with a dual electron multileaf collimator: A feasibility study

被引:1
|
作者
Inyang S.O. [1 ,2 ]
Chamberlain A.C. [1 ]
机构
[1] Department of Medical Physics, University of Limpopo, Medunsa 0204, Medunsa Campus
[2] Department of Physics, University of Calabar, Calabar
关键词
Depth dose; Electron therapy; EMLC; Monte Carlo; Multileaf collimator; Penumbra;
D O I
10.1007/s12194-009-0068-z
中图分类号
学科分类号
摘要
Electron applicators and cut-outs have been used for some time in the delivery of electron beam therapy. A dual electron multileaf collimator (eMLC) consisting of upper and lower eMLCs was designed, and dose distributions of electron beams delivered by it were evaluated by Monte Carlo simulations by use of the EGSnrc Monte Carlo code. The percentage depth dose (PDD), dose profiles, dose gradient falloff (G), depth of maximum dose (R 100), surface dose, bremsstrahlung background, beam flatness, and penumbra of the dual eMLC were evaluated and compared with those simulated and measured with the standard applicators inserted into the treatment head of the medical linear accelerator (linac). The results showed good agreement in most cases. Specifically, the flatness and penumbra obtained with the dual eMLC were better than those obtained with standard applicators. It is therefore possible to use the proposed dual eMLC in the delivery of electron beam therapy without the need for applicators and cut-outs. This will minimize the inconvenience of placing cut-outs on the patients; also, changes in the required field can be effected without the therapist going into the accelerator room when the dual eMLC is finally automated. The absence of a helium bag between the upper and lower eMLCs did not offer significant changes in the dosimetry parameters compared to the eMLC fitted with the helium bag. © 2009 Japanese Society of Radiological Technology and Japan Society of Medical Physics.
引用
收藏
页码:210 / 218
页数:8
相关论文
共 50 条
  • [1] Characteristics of electron beams collimated by an electron multileaf collimator
    Jin, L.
    Ma, C.
    ElDib, A.
    Fan, I.
    Lin, T.
    Li, J.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2643 - 2643
  • [2] Monte Carlo and experimental investigations of multileaf collimated electron beams for modulated electron radiation therapy
    Lee, MC
    Jiang, SB
    Ma, CM
    [J]. MEDICAL PHYSICS, 2000, 27 (12) : 2708 - 2718
  • [3] Qualitative analysis of irregular fields delivered with dual electron multileaf collimator: A Monte Carlo study
    Inyang, Samuel Okon
    Chamberlain, Alan
    [J]. POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2016, 22 (01) : 5 - 9
  • [4] Monte Carlo Modeling of Modulated Electron Beams Delivered Through a Photon Multileaf Collimator
    Tynan, P.
    Stathakis, S.
    Esquivel, C.
    Papanikolaou, N.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [5] Monte Carlo simulations of multileaf collimated electrons
    Lee, MC
    Jiang, SB
    Yi, BY
    Ma, CM
    [J]. USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 176 - 178
  • [6] A Feasibility Study to Replace Electron Cutouts with a Motorized Electron Multileaf Collimator
    Eldib, A.
    Li, J.
    Jin, L.
    Ma, C.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3806 - 3806
  • [7] Monte Carlo simulations of the dosimetric characteristics of a new multileaf collimator
    Tacke, M
    Szymanowski, H
    Schulze, C
    Nuss, S
    Wehrwein, E
    Leidenberger, S
    Oelfke, U
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 2018 - 2018
  • [8] Characteristics of scattered electron beams shaped with a multileaf collimator
    Moran, JM
    Martel, MK
    Bruinvis, IAD
    Fraass, BA
    [J]. MEDICAL PHYSICS, 1997, 24 (09) : 1491 - 1498
  • [9] Monte Carlo investigation of electron beams collimated by an electron-specific MLC for modulated electron radiotherapy
    Eldib, A.
    Jin, L.
    Fan, J.
    Li, J.
    Ma, C.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2471 - 2471
  • [10] Using Monte Carlo methods to commission electron beams: A feasibility study
    Antolak, JA