A polymer-based bidirectional micropump driven by a PZT bimorph

被引:0
|
作者
Yi Luo
Miao Lu
Tianhong Cui
机构
[1] University of Minnesota,Department of Mechanical Engineering
来源
Microsystem Technologies | 2011年 / 17卷
关键词
Back Pressure; Driving Frequency; Flow Rate Peak; Valve Seat; PMMA Substrate;
D O I
暂无
中图分类号
学科分类号
摘要
This paper presents a polymer-based micropump for liquid control or drug delivery. The dimension of the pump was 20 × 24 × 3 mm3. A pair of O-ring SU-8 passive valves was fabricated by lift-off technique to control the fluid movement. Micropumps with dimple, bridge, and cantilever valves were studied. The PZT bimorph acted on the polymer membrane to periodically drive fluid. The maximum flow rate was 16.4 ml/min, and the back pressure was 1,525 mmH2O at 150 V (Vp-p). In frequency sweeping experiments, two flow rate peaks and back pressure peaks were analyzed. Bidirectional flow rate was achieved by changing the valve seat from a one-size hole to a step hole. The maximum backward flow rate was 5.1 ml/min, and the driving frequency was about 355 Hz higher than the forward flow rate driving frequency.
引用
收藏
页码:403 / 409
页数:6
相关论文
共 50 条
  • [1] A polymer-based bidirectional micropump driven by a PZT bimorph
    Luo, Yi
    Lu, Miao
    Cui, Tianhong
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2011, 17 (03): : 403 - 409
  • [2] A PZT-driven micropump
    Wang, XH
    Zhou, ZY
    Ye, XY
    Li, Y
    Zhang, WD
    MHS '98, PROCEEDINGS OF THE 1998 INTERNATIONAL SYMPOSIUM ON MICROMECHATRONICS AND HUMAN SCIENCE, 1998, : 269 - 272
  • [3] A Hybrid Silicon-PDMS Micropump Actuated by PZT Bimorph
    Haining Wang Dafu Cui Zhaoxin Geng Xing Chen State Key Labof Transducer TechInstof ElectronicsChinese Academy of SciencesBeijing China
    稀有金属材料与工程, 2006, (S3) : 319 - 320
  • [4] OPTICAL FIBER SWITCH DRIVEN BY PZT BIMORPH
    OHMORI, Y
    OGIWARA, H
    APPLIED OPTICS, 1978, 17 (22): : 3531 - 3532
  • [5] A miniaturized polymer-based bimorph actuator with self-sensing capability
    Tan, Huey Shy
    Chen, Hsuan-Yu
    Chiu, Ying-Hsuan
    Youh, Ru-Yi
    Yang, Yao-Joe Joseph
    AIP ADVANCES, 2021, 11 (08) : 1ENG
  • [6] Polymer-based new type of micropump for bio-medical application
    Guo, SX
    Asaka, K
    2003 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1-3, PROCEEDINGS, 2003, : 1830 - 1835
  • [7] Development, characterization, and theoretical evaluation of electroactive polymer-based micropump diaphragm
    Xu, TB
    Su, J
    SENSORS AND ACTUATORS A-PHYSICAL, 2005, 121 (01) : 267 - 274
  • [8] A Novel Integrated PZT-Driven Micropump and Microvalve
    Zhaoxin Geng Dafu Cui Haining Wang Changchun Liu Bo Su State Key Labof Transducer TechInstof ElectronicsChinese Academy of SciencesBeijing China
    稀有金属材料与工程, 2006, (S3) : 540 - 542
  • [9] The dynamic micropump driven with a screen printed PZT actuator
    Koch, M
    Evans, AGR
    Brunnschweiler, A
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 1998, 8 (02) : 119 - 122
  • [10] A novel integrated PZT-Driven micropump and microvalve
    Geng, Zhaoxin
    Cui, Dafu
    Wang, Haining
    Liu, Changchun
    Su, Bo
    RARE METAL MATERIALS AND ENGINEERING, 2006, 35 : 540 - 542