Can venous occlusion plethysmography be used to measure high rates of arterial inflow?

被引:0
|
作者
Rachel E. Wood
Ian B. Stewart
机构
[1] Queensland University of Technology,School of Human Movement Studies, Institute of Health and Biomedical Innovation
来源
关键词
Forearm; Venous occlusion strain gauge plethysmography; Blood flow;
D O I
暂无
中图分类号
学科分类号
摘要
To investigate whether venous occlusion plethysmography (VOP) may be used to measure high rates of arterial inflow associated with exercise, venous occlusions were performed at rest, and following dynamic handgrip exercise at 15, 30, 45, and 60% of maximum voluntary contraction (MVC) in seven healthy males. The effect of including more than one cardiac cycle in the calculation of blood flow was assessed by comparing the cumulative blood flow over one, two, three, or four cardiac cycles. The inclusion of more than one cardiac cycle at 30 and 60% MVC, and more than two cardiac cycles at 15 and 45% MVC resulted in a lower blood flow compared to using only the first cardiac cycle (P < 0.05). Despite the small time interval over which arterial inflow was measured (~1 s), this did not affect the reproducibility of the technique. Reproducibility (coefficient of variation for arterial inflow over three trials) tended to be poorer at the higher workloads, although this was not significant (12.7 ± 6.6, 16.2 ± 7.3, and 22.9 ± 9.9% for the 15, 30, and 45% MVC workloads; P = 0.102). There was also a tendency for greater reproducibility with the inclusion of more cardiac cycles at the highest workload, but this did not reach significance (P = 0.070). In conclusion, when calculated over the first cardiac cycle only during venous occlusion, high rates of forearm blood flow can be measured using VOP, and this can be achieved without a significant decrease in the reproducibility of the measurement.
引用
收藏
页码:239 / 245
页数:6
相关论文
共 49 条
  • [1] Can venous occlusion plethysmography be used to measure high rates of arterial inflow?
    Wood, Rachel E.
    Stewart, Ian B.
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2010, 108 (02) : 239 - 245
  • [2] VENOUS OCCLUSION PLETHYSMOGRAPHY REDUCES ARTERIAL FLOW
    HIATT, WR
    HUANG, SY
    REGENSTEINER, JG
    MICCO, A
    MANCOJOHNSON, M
    REEVES, JT
    CLINICAL RESEARCH, 1987, 35 (03): : A286 - A286
  • [3] Venous cuff pressures from 30 mmHg to diastolic pressure are recommended to measure arterial inflow by plethysmography
    Groothuis, JT
    van Vliet, L
    Kooijman, M
    Hopman, MTE
    JOURNAL OF APPLIED PHYSIOLOGY, 2003, 95 (01) : 342 - 347
  • [4] VENOUS OCCLUSION PLETHYSMOGRAPHY REDUCES ARTERIAL DIAMETER AND FLOW VELOCITY
    HIATT, WR
    HUANG, SY
    REGENSTEINER, JG
    MICCO, AJ
    ISHIMOTO, G
    MANCOJOHNSON, M
    DROSE, J
    REEVES, JT
    JOURNAL OF APPLIED PHYSIOLOGY, 1989, 66 (05) : 2239 - 2244
  • [5] A novel model to simulate venous occlusion plethysmography data and to estimate arterial and venous parameters
    de Macedo A.R.
    Machado J.C.
    Luz L.M.S.
    da Nobrega A.C.L.
    de Souza M.N.
    Research on Biomedical Engineering, 2020, 36 (04) : 463 - 473
  • [6] EVALUATION OF COMPENSATION IN CHRONIC ARTERIAL OCCLUSION USING ULTRASONIC DOPPLER METHOD AND VENOUS OCCLUSION PLETHYSMOGRAPHY
    KOHLER, M
    ZAHNOW, W
    HINGER, HU
    ZEITSCHRIFT FUR KREISLAUFFORSCHUNG, 1972, 61 (05): : 401 - &
  • [7] CHANGES IN ARTERIAL BLOOD-FLOW VOLUME DURING VENOUS OCCLUSION PLETHYSMOGRAPHY
    GERTSCH, P
    MEISTER, JJ
    MARQUIS, C
    MOSIMANN, R
    SCHWEIZERISCHE MEDIZINISCHE WOCHENSCHRIFT, 1983, 113 (44) : 1628 - 1630
  • [8] COMPARATIVE MEASUREMENTS OF MUSCLE PERFUSION WITH VENOUS OCCLUSION PLETHYSMOGRAPHY AND CLEARANCE WITH XENON-133 IN ARTERIAL OCCLUSION
    MORL, H
    GABRIEL, R
    BARTUSCH, M
    ZEITSCHRIFT FUR KREISLAUFFORSCHUNG, 1971, 60 (05): : 447 - &
  • [9] VENOUS OCCLUSION PLETHYSMOGRAPHY AND BIOMARKERS AS EVALUATION METHODS OF ENDOTHELIUM FUNCTION IN PATIENTS WITH ARTERIAL HYPERTENSION
    Junqueira, C.
    Magalhaes, M.
    Brandao, A.
    Ferreira, E.
    Junqueira, A.
    Neto, J.
    Bottino, D.
    Bouskela, E.
    JOURNAL OF HYPERTENSION, 2016, 34 : E339 - E340
  • [10] THE VALUE OF DOPPLER SONOGRAPHY, ELECTRONIC CUFF OSCILLOGRAPHY, AND VENOUS OCCLUSION PLETHYSMOGRAPHY FOR EVALUATING THE RESULTS OF ARTERIAL RECONSTRUCTIONS
    SEBOLDT, H
    WEBER, P
    HUTH, C
    KURTZ, B
    THORACIC AND CARDIOVASCULAR SURGEON, 1982, 30 (01): : 38 - 38