A Hardware and Software Facility for Calibration and Adjustment of Ion Mass Spectrometers for Space Missions

被引:0
|
作者
D. A. Moiseenko
O. L. Vaisberg
A. Yu. Shestakov
R. N. Zhuravlev
S. D. Shuvalov
M. V. Mitjurin
P. P. Moiseev
I. I. Nechushkin
E. I. Rodkin
A. D. Vasiliev
V. V. Letunovsky
机构
[1] Space Research Institute,
[2] Russian Academy of Sciences,undefined
[3] ООО NPP Astron-Electronics,undefined
关键词
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:350 / 359
页数:9
相关论文
共 20 条
  • [1] A Hardware and Software Facility for Calibration and Adjustment of Ion Mass Spectrometers for Space Missions
    Moiseenko, D. A.
    Vaisberg, O. L.
    Shestakov, A. Yu.
    Zhuravlev, R. N.
    Shuvalov, S. D.
    Mitjurin, M. V.
    Moiseev, P. P.
    Nechushkin, I. I.
    Rodkin, E. I.
    Vasiliev, A. D.
    Letunovsky, V. V.
    [J]. INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2019, 62 (03) : 350 - 359
  • [2] A MODERN AND FULLY AUTOMATED CALIBRATION SYSTEM FOR SPACE ION MASS SPECTROMETERS
    STEINACHER, M
    JOST, F
    SCHWAB, U
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (08): : 4180 - 4187
  • [3] CROSS CALIBRATION OF SECONDARY ION MASS SPECTROMETERS
    RUDENAUER, F
    STEIGER, W
    RIEDEL, M
    BESKE, HE
    HOLZBRECHER, H
    DUSTERHOFT, H
    GERICKE, M
    RICHTER, CE
    RIETH, M
    TRAPP, M
    GIBER, J
    SOLYOM, A
    MAI, H
    STINGEDER, G
    [J]. ANALYTICAL CHEMISTRY, 1985, 57 (08) : 1636 - 1643
  • [4] Case study of the electrical hardware and software for a flowmeter calibration facility
    Baker, Roger C.
    Gautrey, Dave P.
    Mahadeva, Dharshanie V.
    Sennitt, Simon D.
    Thorne, Alan J.
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 2013, 29 : 9 - 18
  • [5] Calibration procedure for secular frequency scanning in ion trap mass spectrometers
    Snyder, Dalton T.
    Pulliam, Christopher J.
    Cooks, R. Graham
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2016, 30 (10) : 1190 - 1196
  • [6] Advances in Mass Spectrometers for Flyby Space Missions for the Analysis of Biosignatures and Other Complex Molecules
    Fausch, Rico G.
    Schertenleib, Janis A.
    Wurz, Peter
    [J]. UNIVERSE, 2022, 8 (08)
  • [7] Development of certified reference materials of ion-implanted dopants in silicon for calibration of secondary ion mass spectrometers
    Simons, D. S.
    Downing, R. G.
    Lamaze, G. P.
    Lindstrom, R. M.
    Greenberg, R. R.
    Paul, R. L.
    Schiller, S. B.
    Guthrie, W. F.
    [J]. JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2007, 25 (04): : 1365 - 1375
  • [8] A low energy ion beam facility for mass spectrometer calibration: First results
    Meyer, Stefan
    Tulej, Marek
    Wurz, Peter
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (01):
  • [9] Perfect space and time focusing ion optics for multiturn time of flight mass spectrometers
    Ishihara, M
    Toyoda, M
    Matsuo, T
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2000, 197 : 179 - 189