Time-frequency analysis of heart murmurs. Part II: Optimisation of time-frequency representations and performance evaluation

被引:0
|
作者
F. Debiais
L. -G. Durand
Z. Guo
R. Guardo
机构
[1] Institut de Recherches Cliniques de Montréal,Laboratoire de Génie Biomédical
[2] Université de Montréal,Institut de Génie Biomédical, École Polytechnique
关键词
Time-frequency analysis; Parametric modelling; Numerical simulations; Phonocardiogram; Heart murmurs;
D O I
暂无
中图分类号
学科分类号
摘要
The basic parameters of the spectrogram, the Choi-Williams, and the Bessel distributions are adjusted to provide the best time-frequency representations (TFRs) of the simulated murmur signals of mitral stenosis, mitral regurgitation, aortic stenosis, aortic regurgitation, and of two musical murmurs. The initial adjustment of the parameters of each TFR technique is performed by computing and minimising the relative averaged absolute error between the frequency contours at −3dB and −10dB of each TFR of the simulated murmurs and those of the theoretical distribution of the same signals. The results show that the spectrogram generally provides very good to excellent performance in representing the TFRs of stenotic and regurgitant murmurs. Improvements provided by the Choi-Williams and the Bessel distributions are minor but not systematic for the two signal-to-noise ratios tested (0 and 30 dB) and for the two frequency contours estimated. The Bessel and the Choi-Williams distributions provide the best performance for the musical murmurs. The study shows that although a single technique cannot be optimal for all six murmurs, the spectrogram using a Hamming window of 30 ms is an acceptable compromise to detect the six simutated heart murmurs.
引用
收藏
页码:480 / 485
页数:5
相关论文
共 50 条
  • [1] Time-frequency analysis of heart murmurs. Part II: Optimisation of time-frequency representations and performance evaluation
    Debiais, F
    Durand, LG
    Guo, Z
    Guardo, R
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1997, 35 (05) : 480 - 485
  • [2] Time-frequency analysis of heart murmurs. Part I: Parametric modelling and numerical simulations
    Debiais, F
    Durand, LG
    Pibarot, P
    Guardo, R
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1997, 35 (05) : 474 - 479
  • [3] Time-frequency analysis of heart murmurs. Part I: Parametric modelling and numerical simulations
    Debiais, F.
    Durand, L.-G.
    Pibarot, P.
    Guardo, R.
    Medical and Biological Engineering and Computing, 1997, 35 (05): : 474 - 479
  • [4] Time-frequency analysis of heart sounds and murmurs
    Daliman, S
    Sha'ameri, AZ
    ICICS-PCM 2003, VOLS 1-3, PROCEEDINGS, 2003, : 840 - 843
  • [5] Time-frequency analysis of pediatric murmurs
    Lombardo, JS
    Blodgett, LA
    Rosen, RS
    Najmi, AH
    Thompson, WR
    BIOMEDICAL SENSING AND IMAGING TECHNOLOGIES, PROCEEDINGS OF, 1998, 3253 : 177 - 187
  • [6] Time-frequency analysis of systolic murmurs
    Haghighi-Mood, A
    Torry, JN
    COMPUTERS IN CARDIOLOGY 1997, VOL 24, 1997, 24 : 113 - 116
  • [7] Comparison of time-frequency analysis performance on hearts and murmurs
    Daliman, S
    Sha'ameri, AZ
    SCORED 2003: STUDENT CONFERENCE ON RESEARCH AND DEVELOPMENT, PROCEEDINGS: NETWORKING THE FUTURE MIND IN CONVERGENCE TECHNOLOGY, 2003, : 1 - 4
  • [8] A new approach for time-frequency analysis of heart rate variability and assessment of time-frequency representations
    Chan, HL
    Huang, HH
    Wu, CP
    Lin, JL
    JOURNAL OF THE CHINESE INSTITUTE OF ENGINEERS, 1997, 20 (03) : 343 - 353
  • [9] New approach for time-frequency analysis of heart rate variability and assessment of time-frequency representations
    Natl Taiwan Univ, Taipei, Taiwan
    J Chin Inst Eng Trans Chin Inst Eng Ser A, 3 (343-353):
  • [10] Analysing heart murmurs using time-frequency methods
    White, PR
    Collis, WB
    Salmon, AP
    PROCEEDINGS OF THE IEEE-SP INTERNATIONAL SYMPOSIUM ON TIME-FREQUENCY AND TIME-SCALE ANALYSIS, 1996, : 385 - 388