Assessment of cardiac preload and extravascular lung water by single transpulmonary thermodilution

被引:0
|
作者
S. G. Sakka
C. C. Rühl
U. J. Pfeiffer
R. Beale
A. McLuckie
K. Reinhart
A. Meier-Hellmann
机构
[1] Department of Anaesthesiology and Intensive Care Medicine,
[2] Friedrich-Schiller-University of Jena,undefined
[3] Bachstrasse 18,undefined
[4] 07 740 Jena,undefined
[5] Germany e-mail: Meier-Hellmann@anae1.med. uni-jena.de Tel.: + 49-36 41-93 30 41 Fax: + 49-36 41-93 32 56,undefined
[6] Department of Intensive Care Medicine,undefined
[7] Guy's Hospital,undefined
[8] London,undefined
[9] UK,undefined
[10] Institute for Experimental Surgery,undefined
[11] Technical University of Munich,undefined
[12] Munich,undefined
[13] Germany,undefined
[14] Technical University of Munich and Pulsion Medical Systems AG,undefined
[15] Munich,undefined
[16] Germany,undefined
来源
Intensive Care Medicine | 2000年 / 26卷
关键词
Key words Intrathoracic blood volume; Extravascular lung water; Double-indicator dilution technique; Thermodilution;
D O I
暂无
中图分类号
学科分类号
摘要
Objective: Transpulmonary double-indicator dilution is a useful monitoring technique for measurement of intrathoracic blood volume (ITBV) and extravascular lung water (EVLW). In this study, we compared a simpler approach using single arterial thermodilution derived measurements of ITBV and EVLW with the double-indicator dilution technique.¶Design: Prospective observational clinical study.¶Setting: Surgical intensive care units of two university hospitals.¶Patients and methods: Global end-diastolic volume (GEDV) derived from single thermodilution was used for calculation of ITBV. Structural regression analysis of the first two thermo-dye dilution measurements in a derivation population of 57 critically ill patients (38 male, 19 female, 18–79 years, 56 ± 15 years) revealed ITBV = (1.25 · GEDV)–28.4 (ml). This equation was then applied to all first measurements in a validation population of 209 critically ill patients (139 male, 70 female, 10–88 years, mean 53 ± 19 years), and single-thermodilution ITBV (ITBVST) and EVLW (EVLWST) was calculated and compared to thermo-dye dilution derived values (ITBVTD, EVLWTD). For inter-individual comparison, absolute values for ITBV and EVLW were normalised as indexed by body surface area (ITBVI) and body weight (EVLWI), respectively.¶Measurements and results: Linear regression analysis yielded a correlation of ITBVIST = (1.05 · ITBVITD)–58.0 (ml/m2), r = 0.97, P < 0.0001. Bias between ITBVITD and ITBVIST was 7.6 (ml/m2) with a standard deviation of 57.4 (ml/m2). Single-thermodilution EVLWI (EVLWIST) was calculated using ITBVIST and revealed the correlation EVLWIST = (0.83 · EVLWITD) + 1.6 (ml/kg), r = 0.96, P < 0.0001. Bias between EVLWITD and EVLWIST was –0.2 (ml/kg) with a standard deviation of 1.4 (ml/kg). In detail, EVLWIST systematically overestimated EVLWITD at low-normal values for EVLWI and underestimated EVLWI at higher values (above 12 ml/kg).¶Conclusion: Determinations of ITBV and EVLW by single thermodilution agreed closely with the corresponding values from the double-indicator technique. Since transpulmonary single thermodilution is simple to apply, less invasive and cheaper, all these features make it a promising technique for the bedside. Nevertheless, further validation studies are needed in the future.
引用
收藏
页码:180 / 187
页数:7
相关论文
共 50 条
  • [1] Assessment of cardiac preload and extravascular lung water by single transpulmonary thermodilution
    Sakka, SG
    Rühl, CC
    Pfeiffer, UJ
    Beale, R
    McLuckie, A
    Reinhart, K
    Meier-Hellmann, A
    INTENSIVE CARE MEDICINE, 2000, 26 (02) : 180 - 187
  • [2] Assessment of intrathoracic blood volume and extravascular lung water by single transpulmonary thermodilution
    SG Sakka
    A Meier-Hellmann
    K Reinhart
    Critical Care, 3 (Suppl 1):
  • [3] Assessment of intrathoracic blood volume and extravascular lung water by single transpulmonary thermodilution
    Sakka, SG
    Meier-Hellmann, A
    Reinhart, K
    CRITICAL CARE MEDICINE, 1999, 27 (01) : A110 - A110
  • [4] Ex vivo assessment of extravascular lung water with transpulmonary thermodilution
    Trebbia, Gregoire
    Sage, Edouard
    Fadel, Elie
    Sakka, Samir G.
    Cerf, Charles
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2013, 32 (08): : 840 - 842
  • [5] Validation of the extravascular lung water by single transpulmonary thermodilution in the clinical setting
    T Tagami
    S Kushimoto
    T Masuno
    R Tosa
    K Yonezawa
    H Hirama
    Y Imazu
    K Matsuda
    Y Yamamoto
    M Kawai
    H Yokota
    Critical Care, 13 (Suppl 1):
  • [6] Extravascular lung water assessed by transpulmonary single thermodilution and postmortem gravimetry in sheep
    Kirov, MY
    Kuzkov, VV
    Kuklin, VN
    Waerhaug, K
    Bjertnaes, LJ
    CRITICAL CARE, 2004, 8 (06): : R451 - R458
  • [7] Extravascular lung water assessed by transpulmonary single thermodilution and postmortem gravimetry in sheep
    Mikhail Y Kirov
    Vsevolod V Kuzkov
    Vladimir N Kuklin
    Kristine Waerhaug
    Lars J Bjertnaes
    Critical Care, 8
  • [8] Influence of extravascular lung water on transpulmonary thermodilution-derived cardiac output measurement
    Pohl, Thomas
    Kozieras, Jan
    Sakka, Samir G.
    INTENSIVE CARE MEDICINE, 2008, 34 (03) : 533 - 537
  • [9] Influence of extravascular lung water on transpulmonary thermodilution-derived cardiac output measurement
    Thomas Pohl
    Jan Kozieras
    Samir G. Sakka
    Intensive Care Medicine, 2008, 34 : 533 - 537
  • [10] Measurement of cardiac output and extravascular lung water by transpulmonary thermodilution in postoperative monopulmonary transplantation
    Dinh, A. Tran
    Dufour, G.
    Piednoir, P.
    Augustin, P.
    Montravers, P.
    Desmard, M.
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2013, 32 : A47 - A47