Electrochemiluminescent Determination of l-Cysteine with a Flow-Injection Analysis System

被引:0
|
作者
Liande Zhu
Yingxiu Li
Guoyi Zhu
机构
[1] Chinese Academy of Sciences,StateKey Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry
来源
Analytical Sciences | 2003年 / 19卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A flow-injection electrochemiluminescent method for l-cysteine determination has been developed based on its enhancement of the electrochemiluminecence of luminol at a glassy carbon electrode. This method is simple and sensitive for cysteine determination. Under the selected experimental parameters, the linear range for cysteine concentration was 1. 0 × 10–6–5. 0 × 10–5 mol/l, and the detection limit was 0. 67 µmol/l (S/N = 3). The relative standard deviation for 11 measurements of 1. 0 × 10–5 mol/l cysteine was 4. 5%. The proposed method has been applied to the detection of cysteine in pharmaceutical injections with satisfactory results.
引用
收藏
页码:575 / 578
页数:3
相关论文
共 50 条
  • [1] Electrochemiluminescent determination of L-cysteine with a flow-injection analysis system
    Zhu, L
    Li, YX
    Zhu, GY
    ANALYTICAL SCIENCES, 2003, 19 (04) : 575 - 578
  • [2] Determination of L-cysteine in amino acid mixture and human urine by flow-injection analysis with a biamperometric detector
    Zhao, C
    Zhang, JC
    Song, JF
    ANALYTICAL BIOCHEMISTRY, 2001, 297 (02) : 170 - 176
  • [3] Flow-injection simultaneous chemiluminescence determination of ascorbic acid and L-cysteine with partial least squares calibration
    Li, BX
    Wang, DM
    Xu, CL
    Zhang, ZJ
    MICROCHIMICA ACTA, 2005, 149 (3-4) : 205 - 212
  • [4] Flow-Injection Simultaneous Chemiluminescence Determination of Ascorbic Acid and L-Cysteine with Partial Least Squares Calibration
    Baoxin Li
    Dongmei Wang
    Chunli Xu
    Zhujun Zhang
    Microchimica Acta, 2005, 149 : 205 - 212
  • [5] SPECTROFLUOROMETRIC FLOW-INJECTION METHOD FOR THE INDIVIDUAL AND SUCCESSIVE DETERMINATION OF L-CYSTEINE AND L-CYSTINE IN PHARMACEUTICAL AND URINE SAMPLES
    PEREZRUIZ, T
    MARTINEZLOZANO, C
    TOMAS, V
    CARPENA, J
    ANALYST, 1992, 117 (06) : 1025 - 1028
  • [6] Stopped-flow injection analysis for simultaneous determination of ascorbic acid and L-cysteine
    Zeng, Sa
    Tan, Huiling
    Lihua Jianyan: Huaxue Fence/Physical Testing and Chemical Analysis Part B:Chemical Analysis, 2000, 36 (10): : 439 - 441
  • [7] A novel flow-injection chemiluminescence method for determination of baclofen using L-cysteine capped CdS quantum dots
    Khataee, Alireza
    Hasanzadeh, Aliyeh
    Iranifam, Mortaza
    Joo, Sang Woo
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 215 : 272 - 282
  • [8] Determination of N-acetyl-L-cysteine by flow-injection potentiometry
    Radic, N
    Komljenovic, J
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 360 (06): : 675 - 678
  • [9] Determination of N-acetyl-L-cysteine by flow-injection potentiometry
    Nj. Radić
    J. Komljenović
    Fresenius' Journal of Analytical Chemistry, 1998, 360 : 675 - 678
  • [10] Simulation of physical processes in flow-injection system with electrochemiluminescent detector
    Kharkiv National University of Radio Engineering and Electronics, 14, Lenin Ave., Kharkiv, 61166, Ukraine
    Telecommun Radio Eng, 2007, 10 (925-931):