New applications of the good old wavelength-dispersive X-ray fluorescence

被引:0
|
作者
ANDRZEJ KUCZUMOW
PAWEŁ WOLSKI
机构
[1] John Paul II Catholic University of Lublin,Department of Chemistry
来源
Pramana | 2011年 / 76卷
关键词
Wavelength-dispersive X-ray fluorescence; X-ray multilayers; chemical speciation; botanical classification.; 07.85.Nc; 07.85.-m; 07.85.Fv; 82.80.Ej;
D O I
暂无
中图分类号
学科分类号
摘要
Wavelength-dispersive X-ray fluorescence can be characterized by its advantages and drawbacks. Unbeaten spectral resolution in a range below 5 keV, good operational stability, excellent ability of making averaged analysis, and good presentation of peak shape which gives the basis for the chemical speciation are the advantages. Among the drawbacks, the following are important: system with sequential analysis of particular elements, low output of energy supplied to the device, and great cost of instrument which can be amortized only in routine operations. In routine geological and environmental analyses, the WD-XRF performs better than other simpler instrumental or wet techniques. WD-XRF is continuously improved, by applying new multilayer interference mirrors (MIM) for detection and quantification of very light elements. Bad spectral resolution of MIM noted earlier is now improved by tailoring their shape to the shape of gratings. The progress in the long wavelength spectral region joined with efficient and precise wavelength resolution systems enables the application of WD-XRF for speciation analysis. In another effort, XRF spectrometry is treated as a tool for obtaining quantitative basis for the judgement on Linnaean systematic classification of plants and opens the field to a new discipline – quantitative biology.
引用
收藏
页码:213 / 221
页数:8
相关论文
共 50 条
  • [1] New applications of the good old wavelength-dispersive X-ray fluorescence
    Kuczumow, Andrzej
    Wolski, Pawel
    PRAMANA-JOURNAL OF PHYSICS, 2011, 76 (02): : 213 - 221
  • [2] Wavelength-dispersive x-ray fluorescence detector
    Kirkland, J.P.
    Kovantsev, V.E.
    Dozier, C.M.
    Gilfrich, J.V.
    Gibson, W.M.
    Xiao, Qi-Fan
    Umezawa, K.
    Review of Scientific Instruments, 1995, 66 (2 pt 2):
  • [3] Novel wavelength-dispersive X-ray fluorescence spectrometer
    Firsov, A.
    Erko, A.
    Senf, F.
    Rehanek, J.
    Brzhezinskaya, M.
    Wernet, R. Mitzner Ph
    Foehlisch, A.
    11TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI 2012), 2013, 425
  • [4] Wavelength-dispersive x-ray spectrometry
    Reed, SJB
    MIKROCHIMICA ACTA, 1998, : 29 - 36
  • [5] Energy-dispersive vs wavelength-dispersive X-ray fluorescence spectrometry
    Brill, M
    METALL, 1996, 50 (7-8): : 504 - 511
  • [6] Multielement analysis of soils by wavelength-dispersive X-ray fluorescence spectrometry
    Krishna, A. K.
    Murthy, N. N.
    Govil, P. K.
    ATOMIC SPECTROSCOPY, 2007, 28 (06) : 202 - 214
  • [7] WAVELENGTH-DISPERSIVE X-RAY-FLUORESCENCE DETECTOR
    KIRKLAND, JP
    KOVANTSEV, VE
    DOZIER, CM
    GILFRICH, JV
    GIBSON, WM
    XIAO, QF
    UMEZAWA, K
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02): : 1410 - 1412
  • [8] Determination of iron on cloths by wavelength-dispersive x-ray fluorescence spectrometry
    van Dalen, G
    X-RAY SPECTROMETRY, 1999, 28 (03) : 149 - 156
  • [9] Application of Wavelength-Dispersive X-Ray Fluorescence Spectrometry to Biological Samples
    Singh, Vivek K.
    Rai, Pradeep K.
    Pathak, Ashok K.
    Tripathi, Durgesh K.
    Singh, Subhash C.
    Singh, Jagdish P.
    SPECTROSCOPY, 2017, 32 (07) : 41 - 47
  • [10] Determination of Iron on Cloths by Wavelength-Dispersive X-Ray Fluorescence Spectrometry
    Unilever Research Laboratory, Olivier van Noortlaan 120, 3133 AT Vlaardingen, Netherlands
    X-Ray Spectrom., 3 (149-156):