Palladium/palladium oxide coated electrospun fibers for wearable sweat pH-sensors

被引:0
|
作者
Victor C. Diculescu
Mihaela Beregoi
Alexandru Evanghelidis
Raluca F. Negrea
Nicoleta G. Apostol
Ionut Enculescu
机构
[1] National Institute of Materials Physics Bucharest,
[2] University of Bucharest,undefined
[3] Faculty of Physics,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The work describes the development of a flexible, hydrogel embedded pH-sensor that can be integrated in inexpensive wearable and non-invasive devices at epidermal level for electrochemical quantification of H+ ions in sweat. Such a device can be useful for swift, real time diagnosis and for monitoring specific conditions. The sensors’ working electrodes are flexible poly(methyl methacrylate) electrospun fibers coated with a thin gold layer and electrochemically functionalized with nanostructured palladium/palladium oxide. The response to H+ ions is investigated by cyclic voltammetry and electrochemical impedance spectroscopy while open circuit potential measurements show a sensitivity of aprox. −59 mV per pH unit. The modification of the sensing interface upon basic and acid treatment is characterized by scanning and transmission electron microscopy and the chemical composition by X-ray photoelectron spectroscopy. In order to demonstrate the functionality of the pH-sensor at epidermal level, as a wearable device, the palladium/palladium oxide working electrode and silver/silver chloride reference electrode are embedded within a pad of polyacrylamide hydrogel and measurements in artificial sweat over a broad pH range were performed. Sensitivity up to −28 mV/pH unit, response time below 30 s, temperature dependence of approx. 1 mV/°C as well as the minimum volume to which the sensor responses of 250 nanoliters were obtained for this device. The proposed configuration represents a viable alternative making use of low-cost and fast fabrication processes and materials.
引用
收藏
相关论文
共 50 条
  • [1] Palladium/palladium oxide coated electrospun fibers for wearable sweat pH-sensors
    Diculescu, Victor C.
    Beregoi, Mihaela
    Evanghelidis, Alexandru
    Negrea, Raluca F.
    Apostol, Nicoleta G.
    Enculescu, Ionut
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [2] Wearable Iridium Oxide pH Sensors for Sweat pH Measurements
    Yang, Xuesong
    Chawang, Khengdauliu
    Chiao, J. -C.
    2019 IEEE SENSORS, 2019,
  • [3] AN ELECTROCHEMICAL PREPARATION OF PALLADIUM OXIDE PH SENSORS
    BLOOR, LJ
    MALCOLMELAWES, DJ
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1990, 278 (1-2) : 161 - 173
  • [4] PVA Electrospun Fibers Coated with PPy Nanoparticles for Wearable Strain Sensors
    Ding, Jingxian
    Mei, Longxiang
    Guo, Xiaowei
    Guo, Deyu
    Ma, Li
    Gui, Yanghai
    Guo, Dongjie
    MACROMOLECULAR RAPID COMMUNICATIONS, 2023, 44 (12)
  • [5] PALLADIUM - PALLADIUM OXIDE MINIATURE PH ELECTRODE
    LIU, CC
    BOCCHICCHIO, BC
    OVERMYER, PA
    NEUMAN, MR
    SCIENCE, 1980, 207 (4427) : 188 - 189
  • [6] PALLADIUM-PALLADIUM OXIDE PH ELECTRODES
    GRUBB, WT
    KING, LH
    ANALYTICAL CHEMISTRY, 1980, 52 (02) : 270 - 273
  • [7] Advances in Wearable Strain Sensors Based on Electrospun Fibers
    Gao, Zhiyuan
    Xiao, Xiao
    Carlo, Aiden Di
    Yin, Junyi
    Wang, Yanxin
    Huang, Linjun
    Tang, Jianguo
    Chen, Jun
    ADVANCED FUNCTIONAL MATERIALS, 2023, 33 (18)
  • [8] Design and Production of Functionalized Electrospun Fibers for Palladium Recovery
    Di Bonito, Luigi Piero
    Kyriacou, Paraskevas
    Di Colandrea, Antonio
    Di Natale, Francesco
    Ruoppolo, Giovanna
    Krasia-Christoforou, Theodora
    ACS APPLIED POLYMER MATERIALS, 2024, 6 (16): : 9406 - 9419
  • [9] Wearable electrochemical sensors for monitoring of inorganic ions and pH in sweat
    Zhao, Kai
    Kang, Bingbing
    Zhou, Binbin
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (04):
  • [10] HYDROGEN SENSING WITH PALLADIUM-COATED OPTICAL FIBERS
    BUTLER, MA
    GINLEY, DS
    JOURNAL OF APPLIED PHYSICS, 1988, 64 (07) : 3706 - 3712