A Model for the Stray-Light Contamination of the UVCS Instrument on SOHO

被引:0
|
作者
S. R. Cranmer
L. D. Gardner
J. L. Kohl
机构
[1] Harvard-Smithsonian Center for Astrophysics,
来源
Solar Physics | 2010年 / 263卷
关键词
Instrumental effects; Spectrum, ultraviolet;
D O I
暂无
中图分类号
学科分类号
摘要
We present a detailed model of stray-light suppression in the spectrometer channels of the Ultraviolet Coronagraph Spectrometer (UVCS) on the SOHO spacecraft. The control of diffracted and scattered stray light from the bright solar disk is one of the most important tasks of a coronagraph. We compute the fractions of light that diffract past the UVCS external occulter and non-specularly pass into the spectrometer slit. The diffracted component of the stray light depends on the finite aperture of the primary mirror and on its figure. The amount of non-specular scattering depends mainly on the micro-roughness of the mirror. For reasonable choices of these quantities, the modeled stray-light fraction agrees well with measurements of stray light made both in the laboratory and during the UVCS mission. The models were constructed for the bright H i Lyα emission line, but they are applicable to other spectral lines as well.
引用
收藏
页码:275 / 291
页数:16
相关论文
共 50 条
  • [1] A Model for the Stray-Light Contamination of the UVCS Instrument on SOHO
    Cranmer, S. R.
    Gardner, L. D.
    Kohl, J. L.
    SOLAR PHYSICS, 2010, 263 (1-2) : 275 - 291
  • [2] Grating stray-light analysis and control in the UVCS/SOHO
    Fineschi, S
    Gardner, LD
    Kohl, JL
    Romoli, M
    Noci, G
    X-RAY AND ULTRAVIOLET SPECTROSCOPY AND POLARIMETRY II, 1998, 3443 : 67 - 74
  • [3] White light stray light test of the SOHO UVCS
    Leviton, DB
    Gardner, LD
    Fineschi, S
    Jhabvala, MD
    Kohl, JL
    Romoli, M
    Noci, G
    X-RAY AND ULTRAVIOLET SPECTROSCOPY AND POLARIMETRY II, 1998, 3443 : 50 - 60
  • [4] Contamination scatter functions for stray-light analysis
    Dittman, MG
    OPTICAL SYSTEM CONTAMINATION: EFFECTS, MEASUREMENTS, AND CONTROL VII, 2002, 4774 : 99 - 110
  • [5] ON THE INVERSION OF STOKES PROFILES WITH LOCAL STRAY-LIGHT CONTAMINATION
    Ramos, A. Asensio
    Sainz, R. Manso
    ASTROPHYSICAL JOURNAL, 2011, 731 (02):
  • [6] Stray light, radiometric, and spectral characterization of UVCS/SOHO: Laboratory calibration and flight performance
    Gardner, LD
    Kohl, JL
    Daigneau, PS
    Dennis, EF
    Fineschi, S
    Michels, J
    Nystrom, GU
    Panasyuk, A
    Raymond, JC
    Reisenfeld, DJ
    Smith, PL
    Strachan, L
    Suleiman, R
    Noci, G
    Romoli, M
    Ciaravella, A
    Modigliani, A
    Huber, MCE
    Antonucci, E
    Benna, C
    Giordano, S
    Tondello, G
    Nicolosi, P
    Naletto, G
    Pernechele, C
    Spadaro, D
    Siegmund, OHW
    Allegra, A
    Carosso, P
    Jhabvala, M
    ULTRAVIOLET ATMOSPHERIC AND SPACE REMOTE SENSING: METHODS AND INSTRUMENTATION, 1996, 2831 : 2 - 24
  • [7] Stray-light contamination and spatial deconvolution of slit-spectrograph observations
    Beck, C.
    Rezaei, R.
    Fabbian, D.
    ASTRONOMY & ASTROPHYSICS, 2011, 535
  • [8] The stray-light entrance pupil concept and how it can be used to facilitate stray-light characterization
    Clermont, L.
    Michel, C.
    Blain, P.
    Stockman, Y.
    OPTICAL MODELING AND SYSTEM ALIGNMENT, 2019, 11103
  • [9] Model Design and Stray Light Suppression Technology of Stray-Light Testing Equipment for Plane Grating
    Zhai Shan-shan
    Yang Jin
    Bayanheshig
    Cui Ji-cheng
    Qi Xiang-dong
    Tang Yu-guo
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34 (04) : 1124 - 1129
  • [10] EXPOSURE CONTROL AND STRAY-LIGHT COMPONENT
    HARRIS, JW
    JOURNAL OF THE SOCIETY OF MOTION PICTURE TELEVISION ENGINEERS, 1965, 74 (07): : 587 - &