Quantitative multiplex real-time polymerase chain reaction assay for the detection of Helicobacter pylori and clarithromycin resistance

被引:4
|
作者
Kim, Ilsoo [1 ]
Maeng, Lee-So [2 ]
Kim, Joon Sung [1 ]
Kim, Byung-Wook [1 ]
Cheung, Dae Young [3 ]
Kim, Jin Il [3 ]
Park, Soo-heon [3 ]
机构
[1] Catholic Univ Korea, Incheon St Marys Hosp, Coll Med, Dept Internal Med,Div Gastroenterol, Incheon St, Incheon, South Korea
[2] Catholic Univ Korea, Dept Hosp Pathol, Incheon St Marys Hosp, Coll Med, Incheon St, Seoul, South Korea
[3] Catholic Univ Korea, Yeouido St Marys Hosp, Coll Med, Dept Internal Med,Div Gastroenterol, Yeouido St, Seoul, South Korea
关键词
Helicobacter Pylori; Molecular diagnosis; Macrolide Resistance; RAPID UREASE TEST; ANTIBIOTIC-RESISTANCE; MACROLIDE RESISTANCE; TISSUE SAMPLES; PCR; ERADICATION; ELIMINATION; MUTATIONS; MECHANISM; STRAINS;
D O I
10.1186/s12866-023-02868-z
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
BackgroundIdentifying clarithromycin resistance is essential for eradicating Helicobacter pylori (HP). Therefore, we evaluated the performance of Allplex (TM) H.pylori & ClariR Assay (Allplex (TM)) for diagnosing and detecting clarithromycin resistance in HP.MethodsSubjects who underwent esophagogastroduodenoscopy between April 2020 and August 2021 at Incheon St. Mary's hospital were enrolled in this study. The diagnostic performances of Allplex (TM) and dual priming oligonucleotide (DPO)-based multiplex polymerase chain reaction (PCR) were compared with sequencing as the gold standard.ResultsA total of 142 gastric biopsy samples were analyzed. Gene sequencing revealed 124 HP infections, 42 A2143G mutations, 2 A2142G mutations, one dual mutation, and no A2142C mutation. DPO-PCR showed 96.0% sensitivity and 100.0% specificity for HP detection; the corresponding rates for Allplex (TM) were 99.2% and 100.0%. DPO-PCR showed 88.3% sensitivity and 82.0% specificity for A2143G mutation, and Allplex (TM) showed 97.6% and 96.0%. The Cohen's Kappa coefficient for overall test results was 0.56 for DPO-PCR and 0.95 for Allplex (TM).ConclusionAllplex (TM) showed comparable diagnostic performance with direct gene sequencing and non-inferior diagnostic performance to DPO-PCR. Further research is required to confirm whether Allplex (TM) is an effective diagnostic tool for the eradication of HP.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Correction: Quantitative multiplex real-time polymerase chain reaction assay for the detection of Helicobacter pylori and clarithromycin resistance
    Ilsoo Kim
    Lee-So Maeng
    Joon Sung Kim
    Byung-Wook Kim
    Dae Young Cheung
    Jin Il Kim
    Soo-heon Park
    [J]. BMC Microbiology, 23
  • [2] Real-Time Polymerase Chain Reaction for the Detection of Helicobacter pylori and Clarithromycin Resistance
    Noh, Jin Hee
    Ahn, Ji Yong
    Choi, Jene
    Park, Young Soo
    Na, Hee Kyong
    Lee, Jeong Hoon
    Jung, Kee Wook
    Kim, Do Hoon
    Choi, Kee Don
    Song, Ho June
    Lee, Gin Hyug
    Jung, Hwoon-Yong
    Kim, Jung Mogg
    [J]. GUT AND LIVER, 2023, 17 (03) : 375 - 381
  • [3] Screening for Helicobacter pylori infection and Clarithromycin resistance using real-time polymerase chain reaction
    Kovacheva-Slavova, M.
    Valkov, H.
    Angelov, T.
    Tropcheva, R.
    Vladimirov, B.
    [J]. HELICOBACTER, 2020, 25 : 4 - 4
  • [4] Screening for Helicobacter pylori infection and Clarithromycin resistance using Real-Time Polymerase Chain Reaction
    Kovacheva-Slavova, M.
    Valkov, H.
    Angelov, T.
    Tropcheva, R.
    Vladimirov, B.
    [J]. EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2021, 25 (15) : 5042 - 5046
  • [5] Helicobacter Pylori Detection in Shellfish: A Real-Time Quantitative Polymerase Chain Reaction Approach
    Consuelo Pina-Perez, Maria
    Gonzalez, Ana
    Moreno, Yolanda
    Antonia Ferrus, Maria
    [J]. FOODBORNE PATHOGENS AND DISEASE, 2019, 16 (02) : 137 - 143
  • [6] Helicobacter pylori:: identification and detection of clarithromycin resistance by polymerase chain reaction
    Sevin, E
    Lamarque, D
    Delchier, JC
    Soussy, CJ
    Tankovic, J
    [J]. ANNALES DE BIOLOGIE CLINIQUE, 2000, 58 (01) : 81 - 84
  • [7] Helicobacter pylori clarithromycin resistance detected by Etest and TaqMan real-time polymerase chain reaction: a comparative study
    Monno, Rosa
    Giorgio, Floriana
    Carmine, Panella
    Soleo, Leonardo
    Cinquepalmi, Vittoria
    Ierardi, Enzo
    [J]. APMIS, 2012, 120 (09) : 712 - 717
  • [8] Development of a novel real-time polymerase chain reaction assay for the detection of Helicobacter pylori in wastewater samples
    Piqueres, P
    Moreno, Y
    Alonso, JL
    Botella, S
    Hernández, J
    Ferrús, MA
    [J]. HELICOBACTER, 2005, 10 (05) : 521 - 521
  • [9] Primary clarithromycin resistance in Italy assessed on Helicobacter pylori DNA sequences by TaqMan real-time polymerase chain reaction
    De Francesco, V
    Margiotta, M
    Zullo, A
    Hassan, C
    Valle, ND
    Burattini, O
    Cea, U
    Stoppino, G
    Amoruso, A
    Stella, F
    Morini, S
    Panella, C
    Ierardi, E
    [J]. ALIMENTARY PHARMACOLOGY & THERAPEUTICS, 2006, 23 (03) : 429 - 435
  • [10] Primary clarithromycin resistance in the pediatric population assessed on Helicobacter pylori DNA sequences by real-time polymerase chain reaction
    Francavilla, R.
    Lionetti, E.
    Castellaenta, S.
    Magista, A.
    De, Canio A.
    Bucci, N.
    Masciale, A.
    Indrio, F.
    Tetro, A.
    Burattini, O.
    Polizzi, A.
    Ierardi, E.
    Cavallo, L.
    [J]. JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 2007, 44 : 132 - 132