Development and Validation of a Stability-Indicating LC Method for Curcumin

被引:0
|
作者
Prajakta P. Dandekar
Vandana B. Patravale
机构
[1] Institute of Chemical Technology,Department of Pharmaceutical Sciences and Technology
来源
Chromatographia | 2009年 / 69卷
关键词
Column liquid chromatography; Validation and forced degradation; Stability-indicating; Curcumin;
D O I
暂无
中图分类号
学科分类号
摘要
A simple, isocratic, stability-indicating liquid chromatographic method for quantitative determination of curcumin was successfully developed. The chromatographic separations were achieved using a Hi-Q-Sil C18; 4.6 mm × 250 mm and 10 μm particle size column employing acetonitrile and acetate buffer (pH 3.0; 60: 40, v/v) as the mobile phase. The analyte was subjected to acidic, basic, oxidative, thermal and photo degradation. The method was validated with respect to linearity, precision, accuracy, limit of detection and limit of quantification. Curcumin was detected by UV-Vis detector at 425 nm whereas the degradation products were detected at 280 nm. The method was linear over the concentration range of 1–10 μg mL−1. The limit of detection was found to be 0.06 μg mL−1 and the quantification limit was 0.21 μg mL−1. Considerable degradation of the analyte was observed when it was subjected to alkaline conditions. Accuracy, evaluated as recovery, was in the range of 97–103%. Intra-day precision and intermediate precision showed relative standard deviations <1% and <2% respectively.
引用
收藏
页码:871 / 877
页数:6
相关论文
共 50 条
  • [1] Development and Validation of a Stability-Indicating LC Method for Curcumin
    Dandekar, Prajakta P.
    Patravale, Vandana B.
    [J]. CHROMATOGRAPHIA, 2009, 69 (9-10) : 871 - 877
  • [2] Development and validation of a stability-indicating RP-LC method for famciclovir
    Raman, N. V. V. S. S.
    Harikrishna, K. A.
    Prasad, A. V. S. S.
    Reddy, K. Ratnakar
    Ramakrishna, K.
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 50 (05) : 797 - 802
  • [3] DEVELOPMENT AND VALIDATION OF A RAPID AND SIMPLE STABILITY-INDICATING LC METHOD FOR NIFEDIPINE
    Kuminek, Gislaine
    Tagliari, Monika Piazzon
    Granada, Andrea
    Bertol, Charise Dalazen
    Langassner, Silvana Zucolotto
    Segatto Silva, Marcos Antonio
    Stulzer, Hellen Karine
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2010, 33 (17) : 1601 - 1611
  • [4] Development and Validation of a Stability-Indicating LC Method for the Determination of Rupatadine in Pharmaceutical Formulations
    Daniele R. Nogueira
    Felipe B. D’Avila
    Clarice M. B. Rolim
    Sergio L. Dalmora
    [J]. Chromatographia, 2007, 66 : 915 - 919
  • [5] Development and Validation of a Stability-Indicating LC Method for Determination of Ebastine in Tablet and Syrup
    Arend, Marcela Z.
    Cardoso, Simone G.
    Hurtado, Felipe K.
    Ravanello, Aline
    Lanzanova, Fibele A.
    Rolim, Clarice M. B.
    [J]. CHROMATOGRAPHIA, 2009, 69 : 195 - 199
  • [6] Development and Validation of Novel Stability-Indicating LC Method for the Determination of Saxagliptin and Metformin
    Gurav, Sachin Bhanudas
    Bhatia, Neela Manish
    [J]. INDIAN JOURNAL OF PHARMACEUTICAL EDUCATION AND RESEARCH, 2020, 54 (02) : S350 - S357
  • [7] Development and Validation of a Stability-Indicating LC Method for the Assay of Lodenafil Carbonate in Tablets
    Codevilla, Cristiane Franco
    Lemos, Alice Machado
    Delgado, Leila Schreiner
    Bueno Rolim, Clarice Madalena
    Horn Adams, Andrea Ines
    Bergold, Ana Maria
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2011, 49 (07) : 502 - 507
  • [8] Development and Validation of a Stability-Indicating LC Method for Determination of Ebastine in Tablet and Syrup
    Marcela Z. Arend
    Simone G. Cardoso
    Felipe K. Hurtado
    Aline Ravanello
    Fibele A. Lanzanova
    Clarice M. B. Rolim
    [J]. Chromatographia, 2009, 69 : 195 - 199
  • [9] Development and validation of a stability-indicating LC method for the determination of rupatadine in pharmaceutical formulations
    Nogueira, Daniele R.
    D'Avila, Felipe B.
    Rolim, Clarice M. B.
    Dalmora, Sergio L.
    [J]. CHROMATOGRAPHIA, 2007, 66 (11-12) : 915 - 919
  • [10] Development and Validation of a Stability-Indicating LC Method for Determination of Bexarotene in Softgel Dosage Formulation
    Katakam Lakshmi Narasimha Rao
    Kakullamarri Praneeth Rao
    [J]. Chromatographia, 2017, 80 : 1211 - 1224