Background. The Microperimeter 1 (MP-1) allows for fundus-controlled static perimetry of the central visual field. The purpose of this study was to compare MP-1 fundus perimetry with the already established scanning laser ophthalmoscope (SLO) fundus perimetry concerning detected threshold values of light increment sensitivity in normals. Method. In 31 eyes of 31 healthy volunteers a fundus controlled static threshold perimetry was carried out each with the MP-1 (Nidek Technologies) and the SLO (Rodenstock). In the central 21°x12° visual field light increment sensitivity threshold values for 40 corresponding stimulus locations were compared in a restangular 3°-grid. Results. The average light increment sensitivity was 19.1±0.5 dB with the MP-1 and 17.2±0.9 dB with the SLO. On average the threshold values of the 40 corresponding test locations were 1.9±1.3 dB higher with the MP-1 than with the SLO. Conclusion. Both the MP-1 and SLO offer the possibility of a reproducible functional analysis of the central retina under simultaneous fundus control. For comparison of results of the MP-1 and SLO fundus perimetry, a correction factor of approximately 2 dB should be used. © Springer Medizin Verlag 2005.
引用
收藏
页码:214 / 220
页数:6
相关论文
共 5 条
  • [1] Normal Values for Fundus Perimetry with the Microperimeter MP1
    Midena, Edoardo
    Vujosevic, Stela
    Cavarzeran, Fabiano
    OPHTHALMOLOGY, 2010, 117 (08) : 1571 - U135
  • [2] Microperimetry -: Comparison between the MP1 and SLO fundus perimetry
    Rohrschneider, K
    Bültmann, S
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U667 - U667
  • [3] Microperimetry -: Comparison between the MP1 and SLO fundus perimetry
    Rohrschneider, K
    Springer, C
    Bültmann, S
    Völcker, HE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U53 - U53
  • [4] Kinetic microperimetry - Comparison between the MP1 and SLO fundus perimetry
    Rohrschneider, K
    Springer, C
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [5] Ethanol-Induced Gating Alterations in Homomeric slo1 Versus β1-Containing BK Channels
    Kuntamallappanavar, Guruprasad
    Dopico, Alex M.
    JOURNAL OF GENERAL PHYSIOLOGY, 2016, 148 (02): : 20A - 21A