On the dependence of the laser-induced incandescence (LII) signal on soot volume fraction for variations in particle size

被引:0
|
作者
H. Bladh
J. Johnsson
P.-E. Bengtsson
机构
[1] Lund Institute of Technology,Division of Combustion Physics
来源
Applied Physics B | 2008年 / 90卷
关键词
Soot Particle; Direct Simulation Monte Carlo; Primary Particle Size; Soot Volume Fraction; Primary Particle Diameter;
D O I
暂无
中图分类号
学科分类号
摘要
“The laser-induced incandescence (LII) signal is proportional to soot volume fraction” is an often used statement in scientific papers, and it has – within experimental uncertainties – been validated in comparisons with other diagnostic techniques in several investigations. In 1984 it was shown theoretically in a paper by Melton that there is a deviation from this statement in that the presence of larger particles leads to some overestimation of soot volume fractions. In the present paper we present a detailed theoretical investigation of how the soot particle size influences the relationship between LII signal and soot volume fraction for different experimental conditions. Several parameters have been varied; detection wavelength, time and delay of detection gate, ambient gas temperature and pressure, laser fluence, level of aggregation and spatial profile. Based on these results we are able, firstly, to understand how experimental conditions should be chosen in order to minimize the errors introduced when assuming a linear dependence between the signal and volume fraction and secondly, to obtain knowledge on how to use this information to obtain more accurate soot volume fraction data if the particle size is known.
引用
收藏
页码:109 / 125
页数:16
相关论文
共 50 条
  • [1] On the dependence of the laser-induced incandescence (LII) signal on soot volume fraction for variations in particle size
    Bladh, H.
    Johnsson, J.
    Bengtsson, P. -E.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2008, 90 (01): : 109 - 125
  • [2] Soot volume fraction and particle size measurements with laser-induced incandescence
    Mewes, B
    Seitzman, JM
    APPLIED OPTICS, 1997, 36 (03): : 709 - 717
  • [3] Improvement in soot concentration measurements by laser-induced incandescence (LII) through a particle size correction
    Reimann, J.
    Kuhlmann, S. -A.
    Will, S.
    COMBUSTION AND FLAME, 2008, 153 (04) : 650 - 654
  • [4] Laser-induced incandescence for soot particle size and volume fraction measurements using on-line extinction calibration
    Axelsson, B
    Collin, R
    Bengtsson, PE
    APPLIED PHYSICS B-LASERS AND OPTICS, 2001, 72 (03): : 367 - 372
  • [5] Laser-induced incandescence for soot particle size and volume fraction measurements using on-line extinction calibration
    B. Axelsson
    R. Collin
    P.E. Bengtsson
    Applied Physics B, 2001, 72 : 367 - 372
  • [6] Calibration and correction of laser-induced incandescence for soot volume fraction measurements
    Choi, MY
    Jensen, KA
    COMBUSTION AND FLAME, 1998, 112 (04) : 485 - 491
  • [7] Laser-induced incandescence (LII)
    Thomson, K.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2009, 96 (04): : 581 - 581
  • [8] A data set for validation of models of laser-induced incandescence from soot: temporal profiles of LII signal and particle temperature
    Goulay, Fabien
    Schrader, Paul E.
    Lopez-Yglesias, Xerxes
    Michelsen, Hope A.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2013, 112 (03): : 287 - 306
  • [9] A data set for validation of models of laser-induced incandescence from soot: temporal profiles of LII signal and particle temperature
    Fabien Goulay
    Paul E. Schrader
    Xerxes López-Yglesias
    Hope A. Michelsen
    Applied Physics B, 2013, 112 : 287 - 306
  • [10] Laser-induced incandescence (LII)
    K. Thomson
    Applied Physics B, 2009, 96 : 581 - 581