Coronary Blood Flow Assessed by Transthoracic Echocardiography in Neonates

被引:0
|
作者
K. Harada
M. Tamura
T. Orino
K. Yasuoka
机构
[1] Department of Pediatrics,
[2] Akita University School of Medicine,undefined
[3] Akita,undefined
[4] Japan,undefined
来源
Pediatric Cardiology | 2001年 / 22卷
关键词
Key words: Transthoracic echocardiography — Coronary flow — Congenital heart disease;
D O I
暂无
中图分类号
学科分类号
摘要
Coronary flow measurement has provided useful clinical and physiologic information. However, there is little information about values for coronary flow in normal neonates, much less neonates with congenital heart disease. The aim of this study was to assess coronary blood flow in normal neonates and to compare the results with those in infants with ventricular septal defect. The study groups consisted of 12 normal neonates and 9 infants with simple ventricular septal defect associated with pulmonary hypertension. Left ventricular dimension, left ventricular mass, and the diameter of the coronary vessel were measured by standard M-mode and two-dimensional echocardiography. Peak flow velocities, flow velocity integrals, and flow volumes in the left anterior descending and circumflex coronary arteries were measured. The flow signals from the left anterior descending and circumflex coronary arteries were recorded in 84% (10/12) and 17% (2/12), respectively, in the normal neonates and 78% (7/9) and 11% (1/9), respectively, in the patients. The left ventricular end diastolic diameter and mass were significantly lower in normal infants than in the infants with ventricular septal defect (1.56 ± 0.11 vs 1.84 ± 0.09 cm and 5.4 ± 1.6 vs 8.8 ± 0.8 g, respectively, p < 0.01). The mean peak diastolic velocity and the flow velocity time integral in the left anterior descending coronary artery were significantly lower in the normal neonates than in the patients (15 ± 4 vs 28 ± 6 cm/sec and 2.3 ± 0.6 vs 5.9 ± 1.5 cm, respectively, p < 0.01). The coronary flow volume was significantly lower in the normal neonates than in the patients (3.1 ± 1.4 vs 7.9 ± 4.7 ml/min, p < 0.05). However, the flow volume of the left anterior descending coronary artery/left ventricular mass did not show any significant difference between the two groups. Our study demonstrated in neonates that it is feasible to detect noninvasively and to evaluate the flow of the left anterior descending coronary artery under physiologic conditions and abnormal hemodynamic situations. Increased flow volume in the left anterior descending coronary artery in patients with ventricular septal defect may be a compensated mechanism for the increase in oxygen demand of hypertrophic myocardium of the left ventricle.
引用
收藏
页码:189 / 193
页数:4
相关论文
共 50 条
  • [1] Coronary blood flow assessed by transthoracic echocardiography in neonates
    Harada, K
    Tamura, M
    Orino, T
    Yasuoka, K
    PEDIATRIC CARDIOLOGY, 2001, 22 (03) : 189 - 193
  • [2] Effects of Balloon Valvuloplasty on Coronary Blood Flow in Neonates With Critical Pulmonary Valve Stenosis Assessed With Transthoracic Doppler Echocardiography
    Aburawi, Elhadi H.
    Berg, Ansgar
    Pesonen, Erkki
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (02) : 165 - 169
  • [3] Effects of smoking on coronary blood flow velocity and coronary flow reserve assessed by transthoracic Doppler echocardiography
    Park, Seong-Mi
    Shim, Wan-Joo
    Song, Woo-Hyuk
    Lim, Do-Sun
    Kim, Young-Hoon
    Ro, Young-Moo
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2006, 23 (06): : 465 - 470
  • [4] Coronary blood flow velocity in normal infants and young adults assessed by transthoracic echocardiography
    Harada, K
    Orino, T
    Hironaka, C
    Takahashi, Y
    Takada, G
    AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (11): : 1583 - +
  • [5] Impact of Impella on Coronary Flow Assessed by Transthoracic Doppler Echocardiography
    Hada, Masahiro
    Usui, Eisuke
    Wakasa, Nobutaka
    Sasano, Tetsuo
    Kakuta, Tsunekazu
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (10)
  • [6] Successful percutaneous coronary intervention significantly improves coronary sinus blood flow as assessed by transthoracic echocardiography
    Lyubarova R.
    Boden W.E.
    Fein S.A.
    Schulman-Marcus J.
    Torosoff M.
    Journal of Echocardiography, 2018, 16 (2) : 65 - 71
  • [7] Estimation of coronary sinus blood flow and coronary flow reserve by transthoracic echocardiography
    Ismail, YA
    Abdelmessih, NK
    Wong, I
    Soldo, S
    Chandraratna, PAN
    CIRCULATION, 1996, 94 (08) : 146 - 146
  • [8] Coronary Blood Flow by Transthoracic Echocardiography in Children with Endomyocardial Fibrosis
    Aburawi, Elhadi H.
    Liuba, Petru
    Pesonen, Erkki
    PEDIATRIC CARDIOLOGY, 2009, 30 (03) : 371 - 373
  • [9] Coronary Blood Flow by Transthoracic Echocardiography in Children with Endomyocardial Fibrosis
    Elhadi H. Aburawi
    Petru Liuba
    Erkki Pesonen
    Pediatric Cardiology, 2009, 30 : 371 - 373
  • [10] CLINICAL USEFULNESS OF MEASURING CORONARY FLOW VELOCITY/CORONARY FLOW VELOCITY RESERVE ASSESSED BY TRANSTHORACIC DOPPLER ECHOCARDIOGRAPHY
    Takeuchi, Masaaki
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2004, 97 : S19 - S19