Computed tomography imaging with the Adaptive Statistical Iterative Reconstruction (ASIR) algorithm: dependence of image quality on the blending level of reconstruction

被引:0
|
作者
Patrizio Barca
Marco Giannelli
Maria Evelina Fantacci
Davide Caramella
机构
[1] University of Pisa,Department of Physics
[2] INFN,Unit of Medical Physics
[3] Pisa section,Diagnostic and Interventional Radiology
[4] Pisa University Hospital “Azienda Ospedaliero-Universitaria Pisana”,undefined
[5] University of Pisa,undefined
关键词
Computed tomography; Adaptive Statistical Iterative Reconstruction; Image quality; Noise; Modulation transfer function;
D O I
暂无
中图分类号
学科分类号
摘要
Computed tomography (CT) is a useful and widely employed imaging technique, which represents the largest source of population exposure to ionizing radiation in industrialized countries. Adaptive Statistical Iterative Reconstruction (ASIR) is an iterative reconstruction algorithm with the potential to allow reduction of radiation exposure while preserving diagnostic information. The aim of this phantom study was to assess the performance of ASIR, in terms of a number of image quality indices, when different reconstruction blending levels are employed. CT images of the Catphan-504 phantom were reconstructed using conventional filtered back-projection (FBP) and ASIR with reconstruction blending levels of 20, 40, 60, 80, and 100%. Noise, noise power spectrum (NPS), contrast-to-noise ratio (CNR) and modulation transfer function (MTF) were estimated for different scanning parameters and contrast objects. Noise decreased and CNR increased non-linearly up to 50 and 100%, respectively, with increasing blending level of reconstruction. Also, ASIR has proven to modify the NPS curve shape. The MTF of ASIR reconstructed images depended on tube load/contrast and decreased with increasing blending level of reconstruction. In particular, for low radiation exposure and low contrast acquisitions, ASIR showed lower performance than FBP, in terms of spatial resolution for all blending levels of reconstruction. CT image quality varies substantially with the blending level of reconstruction. ASIR has the potential to reduce noise whilst maintaining diagnostic information in low radiation exposure CT imaging. Given the opposite variation of CNR and spatial resolution with the blending level of reconstruction, it is recommended to use an optimal value of this parameter for each specific clinical application.
引用
收藏
页码:463 / 473
页数:10
相关论文
共 50 条
  • [1] Computed tomography imaging with the Adaptive Statistical Iterative Reconstruction (ASIR) algorithm: dependence of image quality on the blending level of reconstruction
    Barca, Patrizio
    Giannelli, Marco
    Fantacci, Maria Evelina
    Caramella, Davide
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2018, 41 (02) : 463 - 473
  • [2] Impact of a New Adaptive Statistical Iterative Reconstruction (ASIR)-V Algorithm on Image Quality in Coronary Computed Tomography Angiography
    Pontone, Gianluca
    Muscogiuri, Giuseppe
    Andreini, Daniele
    Guaricci, Andrea, I
    Guglielmo, Marco
    Baggiano, Andrea
    Fazzari, Fabio
    Mushtaq, Saima
    Conte, Edoardo
    Annoni, Andrea
    Formenti, Alberto
    Mancini, Elisabetta
    Verdecchia, Massimo
    Campari, Alessandro
    Martini, Chiara
    Gatti, Marco
    Fusini, Laura
    Bonfanti, Lorenzo
    Consiglio, Elisa
    Rabbat, Mark G.
    Bartorelli, Antonio L.
    Pepi, Mauro
    ACADEMIC RADIOLOGY, 2018, 25 (10) : 1305 - 1313
  • [3] Influence of adaptive statistical iterative reconstruction algorithm on image quality in coronary computed tomography angiography
    Precht, Helle
    Thygesen, Jesper
    Gerke, Oke
    Egstrup, Kenneth
    Waaler, Dag
    Lambrechtsen, Jess
    ACTA RADIOLOGICA OPEN, 2016, 5 (12):
  • [4] Image quality of iterative reconstruction in cranial CT imaging: comparison of model-based iterative reconstruction (MBIR) and adaptive statistical iterative reconstruction (ASiR)
    S. Notohamiprodjo
    Z. Deak
    F. Meurer
    F. Maertz
    F. G. Mueck
    L. L. Geyer
    S. Wirth
    European Radiology, 2015, 25 : 140 - 146
  • [5] Image quality of iterative reconstruction in cranial CT imaging: comparison of model-based iterative reconstruction (MBIR) and adaptive statistical iterative reconstruction (ASiR)
    Notohamiprodjo, S.
    Deak, Z.
    Meurer, F.
    Maertz, F.
    Mueck, F. G.
    Geyer, L. L.
    Wirth, S.
    EUROPEAN RADIOLOGY, 2015, 25 (01) : 140 - 146
  • [6] Quantitative evaluation of ASiR image quality: An adaptive statistical iterative reconstruction technique
    Van de Casteele, Elke
    Parizel, Paul
    Sijbers, Jan
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [7] Adaptive Statistical Iterative Reconstruction-V Versus Adaptive Statistical Iterative Reconstruction: Impact on Dose Reduction and Image Quality in Body Computed Tomography
    Gatti, Marco
    Marchisio, Filippo
    Fronda, Marco
    Rampado, Osvaldo
    Faletti, Riccardo
    Bergamasco, Laura
    Ropolo, Roberto
    Fonio, Paolo
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (02) : 191 - 196
  • [8] Initial Phantom Study Comparing Image Quality in Computed Tomography Using Adaptive Statistical Iterative Reconstruction and New Adaptive Statistical Iterative Reconstruction V
    Lim, Kyungjae
    Kwon, Heejin
    Cho, Jinhan
    Oh, Jongyoung
    Yoon, Seongkuk
    Kang, Myungjin
    Ha, Dongho
    Lee, Jinhwa
    Kang, Eunju
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (03) : 443 - 448
  • [9] Computed Tomography Image Quality Evaluation of a New Iterative Reconstruction Algorithm in the Abdomen (Adaptive Statistical Iterative Reconstruction-V) a Comparison With Model-Based Iterative Reconstruction, Adaptive Statistical Iterative Reconstruction, and Filtered Back Projection Reconstructions
    Goodenberger, Martin H.
    Wagner-Bartak, Nicolaus A.
    Gupta, Shiva
    Liu, Xinming
    Yap, Ramon Q.
    Sun, Jia
    Tamm, Eric P.
    Jensen, Corey T.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (02) : 184 - 190
  • [10] Effect of radiation dose and adaptive statistical iterative reconstruction on image quality of pulmonary computed tomography
    Sato, Jiro
    Akahane, Masaaki
    Inano, Sachiko
    Terasaki, Mariko
    Akai, Hiroyuki
    Katsura, Masaki
    Matsuda, Izuru
    Kunimatsu, Akira
    Ohtomo, Kuni
    JAPANESE JOURNAL OF RADIOLOGY, 2012, 30 (02) : 146 - 153