A ball valve micro-pump based on axially symmetrical nozzle fabricated by excimer laser micromachining technology

被引:0
|
作者
Hung-Liang Chien
Yung-Chung Lee
机构
[1] National Cheng Kung University,Department of Mechanical Engineering
关键词
Ball valve; Micro-pump; Excimer laser micromachining; 3D-micromechining; Nozzle; Microfluidics;
D O I
暂无
中图分类号
学科分类号
摘要
This paper presents a new type of ball valve micro-pumps with much simplified structure design and excellent performance. The key element in this micro-pump is a pair of ball valves implemented by confining a micro-ball within a nozzle. The nozzles are axially symmetrical with a specifically designed profile and are directly fabricated using excimer laser micromachining approaches. The ball valves are integrated with a flow chamber, an electromagnetically actuated PDMS membrane, and a coil. When passing an alternative current (AC) through the coil, the flow chamber is actuated to pump fluid flowing along one direction which is controlled by the ball valves. The performance of the proposed micro-pump is evaluated using an AC voltage in the range of 2-6 V and a frequency of 10-70 Hz. Experimental results show that a maximum flow rate of 389 μL/min and a maximum back pressure of 423 mm-H2O are achieved. It offers a low-cost, simple, and effective solution for a wide range of microfluidic pumping applications.
引用
收藏
页码:1315 / 1320
页数:5
相关论文
共 14 条
  • [1] A ball valve micro-pump based on axially symmetrical nozzle fabricated by excimer laser micromachining technology
    Chien, Hung-Liang
    Lee, Yung-Chung
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2017, 18 (10) : 1315 - 1320
  • [2] Development of diffuser/nozzle based valve-less micro-pump
    Tanaka, Seiichi
    Tsukamoto, Hiroshi
    Miyazaki, Koji
    Nihon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 2008, 74 (02): : 323 - 328
  • [3] Characteristics of the diffuser/nozzle valve-less micro-pump
    Tanaka, Seiichi
    Tsukamoto, Hiroshi
    Miyazaki, Koji
    FEDSM 2007: PROCEEDINGS OF THE 5TH JOINT AMSE/JSME FLUIDS ENGINEERING SUMMER CONFERENCE VOL 1, PTS A AND B, 2007, : 1135 - 1142
  • [4] Analytical and experimental studies of diffuser/nozzle valve-less micro-pump
    Tanaka, Seiichi
    Moriyama, Shun
    Tsukamoto, Hiroshi
    Miyazaki, Koji
    PROCEEDINGS OF THE MICRO/NANOSCALE HEAT TRANSFER INTERNATIONAL CONFERENCE 2008, PTS A AND B, 2008, : 203 - 210
  • [5] Metallic micro displacement capacitive sensor fabricated by laser micromachining technology
    Lai, Yongjun
    Bordatchev, Evgueni V.
    Nikumb, Suwas K.
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2006, 12 (08): : 778 - 785
  • [6] Metallic micro displacement capacitive sensor fabricated by laser micromachining technology
    Yongjun Lai
    Evgueni V. Bordatchev
    Suwas K. Nikumb
    Microsystem Technologies, 2006, 12
  • [7] The Vibration Pickup of Micro-Pump Diaphragm based on MEMS Technology Design
    Li, Gang
    Li, Lei
    Zhao, Xiaofeng
    Wen, Dianzhong
    Yu, Yang
    MICRO-NANO TECHNOLOGY XV, 2014, 609-610 : 837 - 841
  • [8] A novel valve-less synthetic-jet-based micro-pump
    Luo, ZB
    Xia, ZX
    SENSORS AND ACTUATORS A-PHYSICAL, 2005, 122 (01) : 131 - 140
  • [9] Micro-fabrication of the non-moving part valve micro-pump by hot-embossing technology
    Pun, Ashley Min-Hang
    Lo, Jason Hok-Chun
    Louie, Derek Chi-Hang
    Li, Li-Man
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 242 - 245
  • [10] Symmetrical Ball Check-Valve Based Rotation-Sensitive Pump
    Rahal, Fabio A.
    Saul, Cyro Ketzer
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2013, 135 (11):