Liquid chromatography/time-of-flight mass spectrometry analysis of postmortem blood samples for targeted toxicological screening

被引:0
|
作者
Markus Roman
Lena Ström
Helena Tell
Martin Josefsson
机构
[1] National Board of Forensic Medicine,Department of Forensic Genetics and Forensic Toxicology
[2] Linköping University,Department of Physics, Chemistry and Biology
来源
关键词
Postmortem; Blood; Liquid chromatography; Mass spectrometry; Time of flight; Liquid chromatography/time-of-flight mass spectrometry;
D O I
暂无
中图分类号
学科分类号
摘要
A liquid chromatography/time-of-flight mass spectrometry (LC-TOF-MS) method for targeted toxicological screening in human postmortem blood samples from forensic autopsy cases has been developed, validated and compared with a previously used method using gas chromatography with nitrogen–phosphorus detection (GC-NPD). Separation was achieved within 12 min by high-resolution gradient chromatography. Ions were generated in positive and negative electrospray ionization mode and were detected in 2-GHz single mass spectrometry mode, m/z range 50–1,000. Before injection, 0.25 g blood was prepared by protein precipitation with 500 μL of a mixture of acetonitrile and ethanol containing deuterated internal standards. An in-house database comprising 240 drugs and metabolites was built by analysing solutions from certified standards or other documented reference material available. Identification was based on scoring of retention time, accurate mass measurement and isotopic pattern. Validation was performed on spiked blood samples and authentic postmortem blood samples. The thresholds defined as minimum required performance levels were for most compounds in the range from 0.01 to 0.10 μg/g. Typically, a mass error of less than 2 ppm and a precision of area measurements of less than 5 % coefficient of variation were achieved. Positive identification was confirmed at concentrations up to 500 μg/g. Most compounds were determined in positive ionization mode, but for a limited number of compounds (fewer than 4 %) negative ionization was needed and a few early-eluted compounds could not be identified owing to substantial influence of interferences from the matrix and were thus not included in the screening. A robust and valid toxicological screening by LC-TOF-MS for postmortem blood samples, covering 50 % more compounds, and with higher precision and sensitivity than the previously used screening by GC-NPD was achieved.
引用
收藏
页码:4107 / 4125
页数:18
相关论文
共 50 条
  • [1] Liquid chromatography/time-of-flight mass spectrometry analysis of postmortem blood samples for targeted toxicological screening
    Roman, Markus
    Strom, Lena
    Tell, Helena
    Josefsson, Martin
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (12) : 4107 - 4125
  • [2] Toxicological screening with formula-based metabolite identification by liquid chromatography/time-of-flight mass spectrometry
    Pelander, A
    Ojanperä, I
    Laks, S
    Rasanen, I
    Vuori, E
    ANALYTICAL CHEMISTRY, 2003, 75 (21) : 5710 - 5718
  • [3] Liquid chromatography/time-of-flight mass spectrometry
    Wang, A.P.L.
    Guo, X.
    Li, L.
    Analytical Chemistry, 1994, 66 (21)
  • [4] Quantitative liquid chromatography/time-of-flight mass spectrometry
    Williamson, Leah N.
    Bartlett, Michael G.
    BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (06) : 567 - 576
  • [5] Herbal medicine analysis by liquid chromatography/time-of-flight mass spectrometry
    Zhou, Jian-Liang
    Qi, Lian-Wen
    Li, Ping
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (44) : 7582 - 7594
  • [6] Screening for anabolic steroids and related compounds in illegal cocktails by liquid chromatography/time-of-flight mass spectrometry and liquid chromatography/quadrupole time-of-flight tandem mass spectrometry with accurate mass measurement
    Nielen, MWF
    Vissers, JPC
    Fuchs, REM
    van Velde, JW
    Lommen, A
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (17) : 1577 - 1585
  • [7] Detection of Gliclazide in Aqueous Samples using Liquid Chromatography/Time-of-Flight/Mass Spectrometry
    Al-Qaim, Fouad Fadhil
    Abdullah, Md Pauzi
    Latip, Jalifah
    Khalik, Wan Mohd Afiq Wan Mohd
    Abu Tahrim, Nurfaizah
    Abidin, Nurul Auni Zainal
    Othman, Mohamed Rozali
    SAINS MALAYSIANA, 2016, 45 (05): : 803 - 810
  • [8] Analysis of sucralose and other sweeteners in water and beverage samples by liquid chromatography/time-of-flight mass spectrometry
    Ferrer, Imma
    Thurman, E. Michael
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (25) : 4127 - 4134
  • [9] Analysis of 100 pharmaceuticals and their degradates in water samples by liquid chromatography/quadrupole time-of-flight mass spectrometry
    Ferrer, Imma
    Thurman, E. Michael
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1259 : 148 - 157
  • [10] Development of a broad toxicological screening technique for urine using ultra-performance liquid chromatography and time-of-flight mass spectrometry
    Lee, Hon Kit
    Ho, Chung Shun
    Iu, Yan Ping Heidi
    Lai, Po Shan Judy
    Shek, Chi Chung
    Lo, Yun-Chuen
    Klinke, Helene Bendstrup
    Wood, Michelle
    ANALYTICA CHIMICA ACTA, 2009, 649 (01) : 80 - 90