The possibility of using the pharmaceutical substance Validol as a reference sample instead of a model mixture of components was theoretically considered for the analysis of Validol tablets. It was shown that the maximum relative error appeared because the difference in the compositions of the reference sample and the substance used in production should not exceed 2.5%. A procedure was developed for the analysis of Validol tablets. The performance characteristics of the procedure and the accuracy of the results were determined in an analysis of model mixtures and commercial tablets.