Improvement of the insertion axis for cochlear implantation with a robot-based system

被引:0
|
作者
Renato Torres
Guillaume Kazmitcheff
Daniele De Seta
Evelyne Ferrary
Olivier Sterkers
Yann Nguyen
机构
[1] Sorbonne Universités,
[2] Université Pierre et Marie Curie Paris 6 (UPMC Paris 6),undefined
[3] Inserm,undefined
[4] UMR-S 1159 Réhabilitation chirurgicale mini-invasive et robotisée de l’audition,undefined
[5] AP-HP,undefined
[6] GHU Pitié-Salpêtrière,undefined
[7] Service ORL,undefined
[8] Otologie,undefined
[9] implants auditifs et chirurgie de la base du crâne,undefined
[10] Université Lille-1,undefined
[11] Lille Nord-Europe,undefined
[12] Team Defrost Inria,undefined
关键词
Robot-based insertion; Axis improvement; Navigation; Computer-assisted surgery;
D O I
暂无
中图分类号
学科分类号
摘要
It has previously reported that alignment of the insertion axis along the basal turn of the cochlea was depending on surgeon’ experience. In this experimental study, we assessed technological assistances, such as navigation or a robot-based system, to improve the insertion axis during cochlear implantation. A preoperative cone beam CT and a mastoidectomy with a posterior tympanotomy were performed on four temporal bones. The optimal insertion axis was defined as the closest axis to the scala tympani centerline avoiding the facial nerve. A neuronavigation system, a robot assistance prototype, and software allowing a semi-automated alignment of the robot were used to align an insertion tool with an optimal insertion axis. Four procedures were performed and repeated three times in each temporal bone: manual, manual navigation-assisted, robot-based navigation-assisted, and robot-based semi-automated. The angle between the optimal and the insertion tool axis was measured in the four procedures. The error was 8.3° ± 2.82° for the manual procedure (n = 24), 8.6° ± 2.83° for the manual navigation-assisted procedure (n = 24), 5.4° ± 3.91° for the robot-based navigation-assisted procedure (n = 24), and 3.4° ± 1.56° for the robot-based semi-automated procedure (n = 12). A higher accuracy was observed with the semi-automated robot-based technique than manual and manual navigation-assisted (p < 0.01). Combination of a navigation system and a manual insertion does not improve the alignment accuracy due to the lack of friendly user interface. On the contrary, a semi-automated robot-based system reduces both the error and the variability of the alignment with a defined optimal axis.
引用
收藏
页码:715 / 721
页数:6
相关论文
共 50 条
  • [1] Improvement of the insertion axis for cochlear implantation with a robot-based system
    Torres, Renato
    Kazmitcheff, Guillaume
    De Seta, Daniele
    Ferrary, Evelyne
    Sterkers, Olivier
    Nguyen, Yann
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2017, 274 (02) : 715 - 721
  • [2] An Optimized Robot-Based Technique for Cochlear Implantation to Reduce Array Insertion Trauma
    Torres, Renato
    Jia, Huan
    Drouillard, Mylene
    Bensimon, Jean-Loup
    Sterkers, Olivier
    Ferrary, Evelyne
    Nguyen, Yann
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2018, 159 (05) : 900 - 907
  • [3] Automated robot-based screw insertion system
    Lara, B
    Althoefer, K
    Seneviratne, LD
    IECON '98 - PROCEEDINGS OF THE 24TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-4, 1998, : 2440 - 2445
  • [4] Robot-based assistance in middle ear surgery and cochlear implantation: first clinical report
    Sykopetrites Vittoria
    Ghizlene Lahlou
    Renato Torres
    Hannah Daoudi
    Isabelle Mosnier
    Stéphane Mazalaigue
    Evelyne Ferrary
    Yann Nguyen
    Olivier Sterkers
    European Archives of Oto-Rhino-Laryngology, 2021, 278 : 77 - 85
  • [5] Robot-based assistance in middle ear surgery and cochlear implantation: first clinical report
    Vittoria, Sykopetrites
    Lahlou, Ghizlene
    Torres, Renato
    Daoudi, Hannah
    Mosnier, Isabelle
    Mazalaigue, Stephane
    Ferrary, Evelyne
    Yann Nguyen
    Sterkers, Olivier
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2021, 278 (01) : 77 - 85
  • [6] Calibration of a Robot-based Measuring System
    Li, Aiguo
    Wang, Wenbiao
    Wu, Defeng
    2009 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS (ROBIO 2009), VOLS 1-4, 2009, : 1361 - 1364
  • [7] Robot-based Shoe Manufacturing System
    Kim, Min-Gyu
    Kim, Juhyun
    Shin, Dongbin
    Jin, Maolin
    2018 18TH INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS (ICCAS), 2018, : 1491 - 1494
  • [8] Calibration for robot-based measuring system
    Li, Ai-Guo
    Ma, Zi
    Wang, Wen-Biao
    Kongzhi Lilun Yu Yingyong/Control Theory and Applications, 2010, 27 (05): : 663 - 667
  • [9] KRISS Robot-Based Antenna Measurement System
    Kwon, Jae-Yong
    Jung, Woohyun
    Cho, Chihyun
    2024 18TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION, EUCAP, 2024,
  • [10] Knowledge Representation System for Robot-Based Automated Assembly
    Jain, Anil
    Donath, Max
    JOURNAL OF DYNAMIC SYSTEMS MEASUREMENT AND CONTROL-TRANSACTIONS OF THE ASME, 1989, 111 (03): : 462 - 469