Assessment of energy loss in aortic stenosis using Bayesian multipoint phase-contrast MRI

被引:0
|
作者
Christian Binter
Robert Manka
Simon H Sündermann
Verena Knobloch
Matthias Stuber
Sebastian Kozerke
机构
[1] University and ETH Zurich,Institute for Biomedical Engineering
[2] University Hospital Zurich,Dept. of Cardiology
[3] University Hospital Zurich,Division of Cardiovascular Surgery
[4] University of Lausanne,Center for Biomedical Imaging (CIBM)
[5] King's College London,Imaging Sciences and Biomedical Engineering
关键词
Aortic Valve; Turbulent Kinetic Energy; Valve Replacement; Aortic Stenosis; Aortic Valve Replacement;
D O I
10.1186/1532-429X-15-S1-P47
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [1] Slice positioning in phase-contrast MRI impacts aortic stenosis assessment
    Troger, Felix
    Tiller, Christina
    Reindl, Martin
    Lechner, Ivan
    Holzknecht, Magdalena
    Pamminger, Mathias
    Poskaite, Paulina
    Kremser, Christian
    Ulmer, Hanno
    Gizewski, Elke Ruth
    Bauer, Axel
    Reinstadler, Sebastian
    Metzler, Bernhard
    Klug, Gert
    Mayr, Agnes
    EUROPEAN JOURNAL OF RADIOLOGY, 2023, 161
  • [2] On the Accuracy of Viscous and Turbulent Loss Quantification in Stenotic Aortic Flow Using Phase-Contrast MRI
    Binter, Christian
    Gulan, Utku
    Holzner, Markus
    Kozerke, Sebastian
    MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (01) : 191 - 196
  • [3] A Bayesian Model for Highly Accelerated Phase-Contrast MRI
    Rich, Adam
    Potter, Lee C.
    Jin, Ning
    Ash, Joshua
    Simonetti, Orlando P.
    Ahmad, Rizwan
    MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (02) : 689 - 701
  • [4] ASSESSMENT OF AORTIC-VALVE PRESSURE-GRADIENTS WITH PHASE-CONTRAST MRI
    CAPUTO, GR
    DUERINCKX, AJ
    HARTIALA, J
    FUJITA, N
    FOSTER, E
    FAZIO, GP
    WINSLOW, T
    HIGGINS, CB
    CIRCULATION, 1992, 86 (04) : 163 - 163
  • [5] MAXIMIZING UNAMBIGUOUS VELOCITY RANGE IN PHASE-CONTRAST MRI WITH MULTIPOINT ENCODING
    Zhao, Shen
    Ahmad, Rizwan
    Potter, Lee C.
    2022 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (IEEE ISBI 2022), 2022,
  • [6] Determination of turbulent kinetic energy via phase-contrast-MRI for the assessment of aortic stenosis severity
    Gotschy, A.
    Binter, C.
    Suendermann, S. H.
    Manka, R.
    Kozerke, S.
    EUROPEAN HEART JOURNAL, 2014, 35 : 544 - 544
  • [7] Aliasing planimetry by phase-contrast imaging for grading of aortic stenosis severity
    Ricci, F.
    Caterino, A. L.
    Mantini, C.
    Rotondo, D.
    Cotroneo, A. R.
    Gallina, S.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2019, 20 : 343 - 343
  • [8] Aliasing planimetry by phase-contrast imaging for grading of aortic stenosis severity
    Ceriello, Laura
    Ricci, Fabrizio
    Caterino, Anna Laura
    Mantini, Cesare
    Rotondo, Domenico
    Cotroneo, Antonio Raffaele
    Gallina, Sabina
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2019, 21 (0J) : J202 - J203
  • [9] Bicuspid Valve-Related Aortic Disease: Flow Assessment with Conventional Phase-Contrast MRI
    Burris, Nicholas S.
    Hope, Michael D.
    ACADEMIC RADIOLOGY, 2015, 22 (06) : 690 - 696
  • [10] Bayesian Motion Recovery Framework for Myocardial Phase-Contrast Velocity MRI
    Huntbatch, Andrew
    Lee, Su-Lin
    Firmin, David
    Yang, Guang-Zhong
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2008, PT II, PROCEEDINGS, 2008, 5242 : 79 - 86