Biological polymeric shielding design for an X-ray laboratory using Monte Carlo codes

被引:0
|
作者
Suffian M. Tajudin
F. Tabbakh
机构
[1] Universiti Sultan Zainal Abidin,Faculty of Health Sciences
[2] Nuclear Science and Technology Research Institute,undefined
来源
关键词
Polymeric compounds; Monte Carlo codes; Gadolinium;
D O I
暂无
中图分类号
学科分类号
摘要
Photon irradiation facilities are often shielded using lead despite its toxicity and high cost. In this study, three Monte Carlo codes, EGS5, MCNPX, and Geant4, were utilized to investigate the efficiency of a relatively new polymeric base compound (CnH2n), as a radiation shielding material for photons with energies below 150 keV. The proposed compound with the densities of 6 and 8 g cm−3 were doped with the weight percentages of 8.0 and 15.0% gadolinium. The probabilities of photoelectric effect and Compton scattering were relatively equal at low photon energies, thus the shielding design was optimized using three Monte Carlo codes for the conformity of calculation results. Consequently, 8% Gd-doped polymer with thickness less than 2 cm and density of 6 g cm−3 was adequate for X-ray room shielding to attenuate more than 95% of the 150-keV incident photons. An average dose rate reduction of 88% can be achieved to ensure safety of the radiation area.
引用
收藏
页码:299 / 304
页数:5
相关论文
共 50 条
  • [1] Biological polymeric shielding design for an X-ray laboratory using Monte Carlo codes
    Tajudin, Suffian M.
    Tabbakh, F.
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2019, 12 (03) : 299 - 304
  • [2] X-RAY COLLIMATOR DESIGN USING MONTE CARLO SIMULATIONS
    Han, Eun Young
    Clarkson, Richard
    Sharma, Sunil
    Corry, Peter M.
    Moros, Eduardo G.
    Ratanatharathorn, Vaneerat
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2013, 25 (06):
  • [3] MONTE CARLO APPLICATION IN SHIELDING DESIGN FOR AN X-RAY CONTAINER/VEHICLE INSPECTION SYSTEM
    Li, Junli
    Ming, Shenjin
    Cao, Yanfeng
    Deng, Yanli
    NUCLEAR TECHNOLOGY, 2009, 168 (02) : 391 - 398
  • [4] Shielding design for the control room of an X-ray cargo container inspection system using Monte Carlo simulations
    Badiei, Shahryar
    Kardan, Mohammad Reza
    Kasesaz, Yaser
    JOURNAL OF INSTRUMENTATION, 2022, 17 (09):
  • [5] Monte Carlo design of X-ray flattening filters
    Li, Quanfeng
    Yan, Huiyong
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2003, 43 (06): : 732 - 734
  • [6] Monte Carlo simulation of X-ray room shielding in diagnostic radiology using PHITS code
    Abdul Aziz, M. Z.
    Yani, S.
    Haryanto, F.
    Ya Ali, N. Kamarullah
    Tajudin, S. M.
    Iwase, H.
    Musarudin, M.
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2020, 13 (01) : 704 - 713
  • [7] Monte Carlo simulation of X-ray source characteristics using MCPETS and MCNPX codes for mammography
    Flegontova, E. Yu.
    Bakaleinikov, L. A.
    Nam, Ki-Yong
    Park, Jung Gon
    Kim, Kyong-Woo
    Chon, Kwon Su
    Yoon, Kwon-Ha
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2007, 51 (01) : 65 - 77
  • [8] Monte Carlo Simulation of Laboratory X-Ray Grating Interferometry Setups
    Tessarini, S.
    Fix, M.
    Volken, W.
    Frei, D.
    Manser, P.
    Vila Comamala, J.
    Stampanoni, M.
    MEDICAL PHYSICS, 2020, 47 (06) : E543 - E543
  • [9] Monte Carlo simulation of x-ray buildup factors of lead and its applications in shielding of diagnostic x-ray facilities
    Kharrati, Hedi
    Agrebi, Amel
    Karaoui, Mohamed-Karim
    MEDICAL PHYSICS, 2007, 34 (04) : 1398 - 1404
  • [10] Diagnostic x-ray dosimetry using Monte Carlo simulation
    Ioppolo, JL
    Price, RI
    Tuchyna, T
    Buckley, CE
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (10): : 1707 - 1720