Wear resistance of nickel–titanium endodontic files after surface treatment

被引:0
|
作者
A. P. R. Alves-Claro
F. A. E. Claro
E. T. Uzumaki
机构
[1] São Paulo State University,Materials and Technology Department
[2] Unesp,Department of Materials
[3] Mechanical Engineering Faculty,undefined
[4] Unicamp,undefined
关键词
Wear Resistance; Root Canal; Titanium Nitride; Implantation Process; Wear Cycle;
D O I
暂无
中图分类号
学科分类号
摘要
Objectives The purpose of this work was to submit the Nitinol files to plasma immersion ion implantation (PIII) and evaluate the effects of the surface treatment. Materials and Methods Wear resistance was determined in vitro by using an equipment for the application of horizontal movements on previously prepared notched plates made of resin. Vickers microhardness was measured in plates and files, before and after surface treatment and the surface chemical composition of the instruments was determined by X-rays photoelectron spectroscopy. Results The hardness values found for the treated Nitinol files were significantly lower than the hardness values measured before the implantation process. The comparison of commercially available instruments shows that the wear resistance of the stainless steel file is higher than the resistance of the Nitinol. Conclusions The results found led to the conclusion that the surface treatment significantly increased the Nitinol files wear resistance.
引用
收藏
相关论文
共 50 条
  • [1] Wear resistance of nickel-titanium endodontic files after surface treatment
    Alves-Claro, A. P. R.
    Claro, F. A. E.
    Uzumaki, E. T.
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2008, 19 (10) : 3273 - 3277
  • [2] Corrosion resistance assessment of nickel-titanium endodontic files with and without heat treatment
    Costa, Tatiana Dias
    da Fonseca e Silva, Elison
    Caetano, Paula Liparini
    da Silva Campos, Marcio Jose
    Resende, Leandro Marques
    Machado, Andre Guimaraes
    Resende do Carmo, Antonio Marcio
    RESTORATIVE DENTISTRY AND ENDODONTICS, 2021, 46 (01):
  • [3] Machining efficiency and wear resistance of nickel-titanium endodontic flies
    Kazemi, RB
    Stenman, E
    Spangberg, LSW
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1996, 81 (05): : 596 - 602
  • [4] Effect From Surface Treatment of Nickel-Titanium Rotary Files on the Fracture Resistance
    Kim, Bo Hoon
    Ha, Jung-Hong
    Lee, Woo Cheol
    Kwak, Sang-Won
    Kim, Hyeon-Cheol
    SCANNING, 2015, 37 (01) : 82 - 87
  • [5] The effect of surface treatments of nickel-titanium files on wear and cutting efficiency
    Rapisarda, E
    Bonaccorso, A
    Tripi, TR
    Fragalk, I
    Condorelli, GG
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2000, 89 (03): : 363 - 368
  • [6] Heat Treatment and Surface Treatment of Nickel-Titanium Endodontic Instruments
    Kwak, Sang Won
    Shen, Ya
    Liu, He
    Wang, Zhejun
    Kim, Hyeon-Cheol
    Haapasalo, Markus
    FRONTIERS IN DENTAL MEDICINE, 2021, 2
  • [7] Surface and cross-sectional characterization of titanium-nitride coated nickel-titanium endodontic files
    Al Jabbari, Youssef S.
    Koutsoukis, Theodoros
    Al Hadlaq, Suliman
    Berzins, David W.
    Zinelis, Spiros
    JOURNAL OF DENTAL SCIENCES, 2016, 11 (01) : 48 - 53
  • [8] Multiscale characterization of nickel-titanium alloy used for endodontic files
    Serres, N.
    Bahlouli, N.
    Hemmerle, J.
    Wagner-Kocher, C.
    Correia, P. de Magalhaes
    Fabre, R.
    Jordan, L.
    Haikel, Y.
    Feugeas, F.
    JA 2013 - JOURNEES ANNUELLES DE LA SF2M 2013 / SF2M ANNUAL MEETING 2013, 2013, 7
  • [9] Torsional properties of stainless steel and nickel-titanium endodontic files
    Rowan, MB
    Nicholls, JI
    Steiner, J
    JOURNAL OF ENDODONTICS, 1996, 22 (07) : 341 - 345
  • [10] Cutting efficiency of different nickel-titanium endodontic files.
    Beer, R. F.
    Stelzner, R. S.
    Gaengler, P.
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : B131 - B131