Diagnostic Accuracy of Glycated Haemoglobin and Average Glucose Values in Type 2 Diabetes Mellitus Treated with Premixed Insulin

被引:0
|
作者
Magdalena Walicka
Jacek Jozwiak
Jacek Rzeszotarski
Anna Zonenberg
Malgorzata Masierek
Pawel Bijos
Edward Franek
机构
[1] Central Clinical Hospital of the Ministry of the Inferior and Administration,Department of Internal Diseases, Endocrinology and Diabetology
[2] Czestochowa University of Technology,Department of Public Health
[3] Silesian Analytical Laboratories,Clinical Department of Internal Diseases and Diabetology
[4] 10th Military Hospital,Medical Institute
[5] Higher School of Computer Science and Business Administration,Department of Human Epigenetics, Mossakowski Medical Research Centre
[6] Bioton SA,undefined
[7] Private Practice,undefined
[8] Polish Academy of Sciences,undefined
来源
Diabetes Therapy | 2019年 / 10卷
关键词
Average blood glucose; Glycated haemoglobin; HbA1c; Premixed insulin; Type 2 diabetes;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:587 / 596
页数:9
相关论文
共 50 条
  • [1] Diagnostic Accuracy of Glycated Haemoglobin and Average Glucose Values in Type 2 Diabetes Mellitus Treated with Premixed Insulin
    Walicka, Magdalena
    Jozwiak, Jacek
    Rzeszotarski, Jacek
    Zonenberg, Anna
    Masierek, Malgorzata
    Bijos, Pawel
    Franek, Edward
    [J]. DIABETES THERAPY, 2019, 10 (02) : 587 - 596
  • [2] Average glucose and respective glycated haemoglobin values in patients with type 2 diabetes: reappraisal of the ADAG study
    Franek, E.
    Rzeszotarski, J.
    Bijos, P.
    Jozwiak, J.
    Zonenberg, A.
    Masierek, M.
    [J]. DIABETOLOGIA, 2013, 56 : S122 - S123
  • [3] Average Glucose Values and Glycated Hemoglobin in Patients With Type 2 Diabetes
    Franek, Edward
    Jozwiak, Jacek
    Bijos, Pawel
    Rzeszotarski, Jacek
    Zonenberg, Anna
    Masierek, Malgorzata
    [J]. DIABETES, 2013, 62 : A643 - A643
  • [4] The relationship between self-monitored blood glucose values and glycated haemoglobin in insulin-treated patients with Type 2 diabetes
    Sarwat, S.
    Ilag, L. L.
    Carey, M. A.
    Shrom, D. S.
    Heine, R. J.
    [J]. DIABETIC MEDICINE, 2010, 27 (05) : 589 - 592
  • [5] Glycated haemoglobin does not accurately predict average capillary glucose in non insulin-treated type 2 diabetes: The PRISMA study experience
    Trevisan, R.
    Bonizzoni, E.
    Bosi, E.
    Ceriello, A.
    Cucinotta, D.
    Giorgino, F.
    Tiengo, A.
    Scavini, M.
    [J]. NUTRITION METABOLISM AND CARDIOVASCULAR DISEASES, 2016, 26 (02) : 169 - 170
  • [6] Correlation Between Blood Glucose and Glycated Haemoglobin Tests in Nigerians with Type 2 Diabetes Mellitus
    Onwukwe, Chikezie Hart
    Odife, Ukamaka
    Igwe, Okpara Ukandu
    Fasanmade, Olufemi Adetola
    Ohwovoriole, Augustine E.
    [J]. ENDOCRINE REVIEWS, 2014, 35 (03)
  • [7] Effect of Chromium-Enriched Yeast on Fasting Plasma Glucose, Glycated Haemoglobin and Serum Lipid Levels in Patients with Type 2 Diabetes Mellitus Treated with Insulin
    Jaroslav Racek
    C. D. Sindberg
    S. Moesgaard
    Josef Mainz
    Jaroslav Fabry
    Luděk Müller
    Katarína Rácová
    [J]. Biological Trace Element Research, 2013, 155 : 1 - 4
  • [8] Effect of Chromium-Enriched Yeast on Fasting Plasma Glucose, Glycated Haemoglobin and Serum Lipid Levels in Patients with Type 2 Diabetes Mellitus Treated with Insulin
    Racek, Jaroslav
    Sindberg, C. D.
    Moesgaard, S.
    Mainz, Josef
    Fabry, Jaroslav
    Mueller, Ludek
    Racova, Katarina
    [J]. BIOLOGICAL TRACE ELEMENT RESEARCH, 2013, 155 (01) : 1 - 4
  • [9] The potential impact of using glycated haemoglobin as the preferred diagnostic tool for detecting Type 2 diabetes mellitus
    Mostafa, S. A.
    Davies, M. J.
    Webb, D.
    Gray, L. J.
    Srinivasan, B. T.
    Jarvis, J.
    Khunti, K.
    [J]. DIABETIC MEDICINE, 2010, 27 (07) : 762 - 769
  • [10] Diagnostic value of glycated haemoglobin as a screening test for diabetes mellitus
    Hu, Y.
    Liu, W.
    Chen, Y.
    Zhang, M.
    Li, S.
    Liu, X.
    Han, T.
    Ji, L.
    [J]. DIABETOLOGIA, 2009, 52 : S122 - S122