Electrochemical Biosensor to Detect Implant-Derived Metal Ions: A Mice Model

被引:0
|
作者
Gokul D. [1 ]
Catton E. [1 ]
Cheng K.Y. [1 ]
Mathew M. [1 ,2 ]
机构
[1] Regenerative Medicine and Disability Research Lab, Department of Biomedical Sciences, University of Illinois College of Medicine, Rockford, IL
[2] Department of Orthopedics, Rush University Medical Centre, Chicago, IL
关键词
Animal model; Biosensor; Electrochemical Impedance Spectroscopy (EIS); Metal ion detection;
D O I
10.1007/s40735-023-00743-y
中图分类号
学科分类号
摘要
Joint replacement surgeries are progressing at an increased rate in the USA, with around 1 million surgeries being performed annually. While these orthopedic implants provide a solution for a damaged joint, debris such as metal ions generated due to the wear and corrosion of the implants prove to be of considerable risk of systemic and local toxicity. As an effective diagnostic tool, there is a need to develop a patient-friendly, cost-effective, and rapid mode of metal ion detection in orthopedic patients with various implants. In this study, an electrochemical biosensor chip (Dropsens) is proposed as a diagnostic tool to detect metal ions through changes in impedance. In vivo studies were conducted using CoCrMo particles intraarticularly injected into mice. Then, blood was collected on 0th day, 14th day, and 28th day after injection and was centrifuged to obtain serum. The serum was subject to various electrochemical techniques, such as Electrochemical Impedance Spectroscopy (EIS) and cyclic voltammetry (CV). Additionally, standardization experiments were performed using different concentrations of CoCrMo wear particles suspended in PBS and mice serum. EIS results reveal a negative correlation between impedance (Rp) and the metal ion concentration in the standardization experiments. EIS and CV standardization data were used to obtain a regression equation which were later used to estimate the metal ion concentrations in experimental samples. Here, the positive control group shows the highest impedance at any frequency followed by the 28th-day experimental mice serum as seen on the bode plot. CV experimental data reveal a possible correlation between CV area and the metal ion concentrations. In this study, experimental mice models were established to mimic the possible diffusion of metal particles from implants. Dropsens electrochemical biosensors were efficiently employed to detect metal ions in serum through changes in impedance. © 2023, The Author(s), under exclusive licence to Springer Nature Switzerland AG.
引用
收藏
相关论文
共 32 条
  • [1] Chemical nature of implant-derived titanium(IV) ions in synovial fluid
    Silwood, CJL
    Grootveld, M
    [J]. BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2005, 330 (03) : 784 - 790
  • [2] Electrochemical Amyloid-Based Biosensor for the Determination of Metal Ions
    Park, Joohyung
    Lee, Wonseok
    Lee, Gyudo
    Choi, Hyunsung
    Kim, Minwoo
    Kim, Woong
    Na, Sungsoo
    Park, Jinsung
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (15) : B1497 - B1505
  • [3] Hydrogen reduction of metal ions: An electrochemical model
    Osseo-Asare, K
    [J]. HYDROMETALLURGY 2003 PROCEEDINGS, VOLS 1 AND 2: VOL 1: LEARNING AND SOLUTION PURIFICATION, 2003, : 1151 - 1165
  • [4] Miniaturized electrochemical biosensor based on whole-cell for heavy metal ions detection in water
    Sciuto, Emanuele L.
    Petralia, Salvatore
    van der Meer, Jan R.
    Conoci, Sabrina
    [J]. BIOTECHNOLOGY AND BIOENGINEERING, 2021, 118 (04) : 1456 - 1465
  • [5] 1H and 51V NMR investigations of the molecular nature of implant-derived vanadium ions in osteoarthritic knee-joint synovial fluid
    Silwood, Christopher J. L.
    Grootveld, Martin
    [J]. CLINICA CHIMICA ACTA, 2007, 380 (1-2) : 89 - 99
  • [6] Hybrid Nanoparticle/DNAzyme Electrochemical Biosensor for the Detection of Divalent Heavy Metal Ions and Cr3+
    Skotadis, Evangelos
    Aslanidis, Evangelos
    Tsekenis, Georgios
    Panagopoulou, Chryssi
    Rapesi, Annita
    Tzourmana, Georgia
    Kennou, Stella
    Ladas, Spyridon
    Zeniou, Angelos
    Tsoukalas, Dimitris
    [J]. SENSORS, 2023, 23 (18)
  • [7] Microbial nanocellulose adherent to human skin used in electrochemical sensors to detect metal ions and biomarkers in sweat
    Silva, Robson R.
    Raymundo-Pereira, Paulo A.
    Campos, Anderson M.
    Wilson, Deivy
    Otoni, Caio G.
    Barud, Hernane S.
    Costa, Carlos A. R.
    Domeneguetti, Rafael R.
    Balogh, Debora T.
    Ribeiro, Sidney J. L.
    Oliveira Jr, Osvaldo N.
    [J]. TALANTA, 2020, 218
  • [8] An ultrasensitive electrochemical sensor based on antimonene simultaneously detect multiple heavy metal ions in food samples
    Zhang, Ya
    Xu, Ying
    Li, Ning
    Liu, Xiaofang
    Ma, Yi
    Luo, Huibo
    Hou, Changjun
    Huo, Danqun
    [J]. FOOD CHEMISTRY, 2023, 421
  • [9] Graphene-derived nanomaterials as recognition elements for electrochemical determination of heavy metal ions: a review
    Zuo, Yinxiu
    Xu, Jingkun
    Zhu, Xiaofei
    Duan, Xuemin
    Lu, Limin
    Yu, Yongfang
    [J]. MICROCHIMICA ACTA, 2019, 186 (03)
  • [10] Graphene-derived nanomaterials as recognition elements for electrochemical determination of heavy metal ions: a review
    Yinxiu Zuo
    Jingkun Xu
    Xiaofei Zhu
    Xuemin Duan
    Limin Lu
    Yongfang Yu
    [J]. Microchimica Acta, 2019, 186