Dental changes evaluated with a 3D computer-assisted model analysis after long-term tongue retaining device wear in OSA patients

被引:0
|
作者
Hui Chen
Alan A. Lowe
Arthur M. Strauss
Fernanda Riberiro de Almeida
Hiroshi Ueda
John A. Fleetham
Bangkang Wang
机构
[1] The University of Medical Sciences,Department of Orthodontics, Faculty of Stomatology
[2] The University of British Columbia,Division of Orthodontics, Department of Oral Health Sciences, Faculty of Dentistry
[3] DDS,Department of Oral Biological and Medical Sciences, Faculty of Dentistry
[4] Private Dental Clinic,Division of Respiratory Medicine, Department of Medicine
[5] Specialist in Snoring & Sleep Apnea,undefined
[6] The University of British Columbia,undefined
[7] The University of British Columbia,undefined
来源
Sleep and Breathing | 2008年 / 12卷
关键词
Obstructive sleep apnea; Oral appliance; Tongue retaining device; Study model; Computer-assisted; Three-dimensional;
D O I
暂无
中图分类号
学科分类号
摘要
Oral appliances (OAs) have been used to treat obstructive sleep apnea (OSA) patients for decades. However, detailed dental side effects in long-term OA cases analyzed with an accurate three-dimensional (3D) measurement tool have seldom been reported. The purpose of this study is to evaluate dental side effects in five OSA patients, who had used a tongue retaining device (TRD) (with occasional other OA wear) for an average of 6 years and 4 months. The baseline and follow-up orthodontic study models were measured with a newly developed MicroScribe-3DX analysis system. High compliance of TRD wear was confirmed in all cases and different patterns and amounts of dental changes were observed. The most common appliance-induced dental changes included anterior and/or unilateral posterior openbites and reduced anterior overjets. It was hypothesized that there might be two possible mechanisms for the TRD side effects—one is the forward pressure of the tongue upon the anterior dental arch and the other is the lateral pressure of the tongue upon the posterior arch. Considerations to correct the TRD dental side effects should be guided by these different mechanisms of the tongue on the dental arch. Possible solutions to minimize occlusal changes and maximize the benefits for OSA patients are also discussed.
引用
收藏
页码:169 / 178
页数:9
相关论文
共 31 条
  • [1] Dental changes evaluated with a 3D computer-assisted model analysis after long-term tongue retaining device wear in OSA patients
    Chen, Hui
    Lowe, Alan A.
    Strauss, Arthur M.
    de Almeida, Fernanda Riberiro
    Ueda, Hiroshi
    Fleetham, John A.
    Wang, Bangkang
    SLEEP AND BREATHING, 2008, 12 (02) : 169 - 178
  • [2] Dental changes evaluated with a 3D computer-assisted model analysis after long-term tongue retaining device wear in OSA patients
    Hui Chen
    Alan A. Lowe
    Arthur M. Strauss
    Fernanda Riberiro de Almeida
    Hiroshi Ueda
    John A. Fleetham
    Bangkang Wang
    Sleep and Breathing, 2009, 13 : 117 - 117
  • [3] Dental changes evaluated with a 3D computer-assisted model analysis after long-term tongue retaining device wear in OSA patients (vol 12, pg 169, 2008)
    Chen, Hui
    Lowe, Alan A.
    Strauss, Arthur M.
    de Almeida, Fernanda Riberiro
    Ueda, Hiroshi
    Fleetham, John A.
    Wang, Bangkang
    SLEEP AND BREATHING, 2009, 13 (01) : 117 - 117
  • [4] COMPUTER-ASSISTED LONG-TERM ECG ANALYSIS IN PATIENTS WITH ARTIFICIAL ATRIAL PACEMAKER (AAI)
    WEBER, H
    GLOGAR, D
    JOSKOWICZ, G
    STEINBACH, K
    PROBST, P
    KAINDL, F
    LASKOVICZ, A
    ZEITSCHRIFT FUR KARDIOLOGIE, 1981, 70 (03): : 151 - 157
  • [5] 3D study model analyses to assess long-term dental changes in sleep apnea patients treated with oral appliances
    Chen, H
    Lowe, AA
    Almeida, F
    Ueda, H
    SLEEP, 2005, 28 : A171 - A171
  • [6] Three-dimensional computer-assisted study model analysis of long-term oral-appliance wear. Part 1: Methodology
    Chen, Hui
    Lowe, Alan A.
    de Almeida, Fernanda Riberiro
    Wong, Mary
    Fleetham, John A.
    Wang, Bangkang
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2008, 134 (03) : 393 - 407
  • [8] Long-term effect of computer-assisted decision support for antibiotic treatment in critically ill patients: a prospective 'before/after' cohort study
    Nachtigall, I.
    Tafelski, S.
    Deja, M.
    Halle, E.
    Grebe, M. C.
    Tamarkin, A.
    Rothbart, A.
    Uhrig, A.
    Meyer, E.
    Musial-Bright, L.
    Wernecke, K. D.
    Spies, C.
    BMJ OPEN, 2014, 4 (12):
  • [9] Long-term dental and skeletal changes in patients submitted to surgically assisted rapid maxillary expansion: A meta-analysis
    Lemes Vilani, Giselle Naback
    Mattos, Claudia Trindade
    de Oliveira Ruellas, Antonio Carlos
    Maia, Lucianne Cople
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2012, 114 (06): : 689 - 697
  • [10] Three-dimensional computer-assisted study model analysis of long-term oral-appliance wear. Part 2. Side effects of oral appliances in obstructive sleep apnea patients
    Chen, Hui
    Lowe, Alan A.
    de Almeida, Fernanda Riberiro
    Fleetham, John A.
    Wang, Bangkang
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2008, 134 (03) : 408 - 417