Reoperation for a Starr-Edwards aortic prosthetic valve 33 years after initial implantation

被引:0
|
作者
Misumi T. [1 ,2 ]
Kudo M. [1 ]
Koizumi K. [1 ]
Kumamaru H. [1 ]
机构
[1] Division of Cardiovascular Surgery, Hiratsuka City Hospital, Hiratsuka, Kanagawa
[2] Division of Cardiovascular Surgery, Hiratsuka City Hospital, Hiratsuka, Kanagawa 254-0065
关键词
Aortic valve replacement; Prosthesis-patient mismatch; Reoperation; Starr-Edwards prosthetic valve;
D O I
10.1007/s11748-005-0026-6
中图分类号
学科分类号
摘要
A 40-year-old woman admitted with heart failure had undergone aortic valve replacement with a Model 2310 Starr-Edwards valve due to aortic regurgitation 33 years previously. She had been followed up for several years, but discontinued follow-up and medication (including Warfarin) for the past 25 years. Echocardiography demonstrated marked dilatation and thickening of the left ventricle, and the peak pressure gradient of the prosthesis was measured as 87.9 mmHg. Under the diagnosis of chronic aortic valve prosthesis-patient mismatch with subsequent severe left ventricular dysfunction, the Starr-Edwards valve was explanted and replaced with a 23 mm St Jude Medical prosthetic valve. The removed valve showed minimal cloth wear except for a small part of the strut The postoperative echocardiography demonstrated recovering of left ventricular function. To our best knowledge, this case presents the longest duration for a surgically explanted Starr-Edwards aortic prosthetic valve in Japan.
引用
收藏
页码:165 / 168
页数:3
相关论文
共 50 条
  • [1] Reoperation for a Starr-Edwards Aortic Valve 33 Years after Initial Implantation Prosthetic
    Misumi, Takahiko
    Kudo, Mikihiko
    Koizumi, Kiyoshi
    Kumamaru, Hiroya
    [J]. GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2005, 53 (03) : 165 - 168
  • [2] Reoperation for a Starr-Edwards aortic valve implanted 28 years earlier
    Katsuhiko Yoshida
    Genyo Fujii
    Shuichi Suzuki
    Hideki Ishida
    Takeru Shimomura
    Akio Matsuura
    [J]. The Japanese Journal of Thoracic and Cardiovascular Surgery, 2002, 50 (8): : 341 - 342
  • [3] Replacement of an aortic Starr-Edwards ball valve prosthesis 28 years after implantation
    Tayama, K
    Akashi, H
    Tayama, E
    Fukunaga, S
    Kawara, T
    Kosuga, K
    Aoyagi, S
    [J]. CIRCULATION JOURNAL, 2004, 68 (05) : 507 - 508
  • [4] Reoperation for a patient with Starr-Edwards aortic valve malfunction due to pannus formation twenty-nine years after implantation
    Okano T.
    Horton M.D.
    Fermanis G.G.
    Horton D.A.
    [J]. The Japanese Journal of Thoracic and Cardiovascular Surgery, 2005, 53 (8) : 437 - 439
  • [5] SURVIVAL AFTER STARR-EDWARDS AORTIC VALVE REPLACEMENT
    SHEAN, FC
    AUSTEN, WG
    BUCKLEY, MJ
    MUNDTH, ED
    SCANNELL, JG
    DAGGETT, WM
    [J]. CIRCULATION, 1971, 44 (01) : 1 - +
  • [6] Starr-Edwards caged-ball aortic valve: preserved function 40 years after implantation
    Yamada, Yasuyuki
    Kiriya, Yuriko
    Ezure, Masahiko
    Kaneko, Tatsuo
    [J]. JOURNAL OF CARDIAC SURGERY, 2016, 31 (09) : 594 - 595
  • [7] Author's reply - Replacement of an aortic Starr-Edwards ball valve prosthesis 28 years after implantation
    Tayama, K
    Akashi, H
    Aoyagi, S
    [J]. CIRCULATION JOURNAL, 2004, 68 (11) : 1093 - 1093
  • [8] FATAL DEGENERATION OF SILICONE RUBBER BALL OF STARR-EDWARDS PROSTHETIC AORTIC VALVE
    ROBERTS, WC
    MORROW, AG
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1968, 22 (05): : 614 - &
  • [9] 49 years of normal functioning Starr-Edwards aortic valve prosthesis
    Sabouni, Mouhamed Amr
    Baumeister, Robin H.
    Traverse, Paul
    [J]. OXFORD MEDICAL CASE REPORTS, 2020, (02): : 39 - 42
  • [10] Transcatheter aortic valve implantation in a patient with previous Starr-Edwards mitral valve prosthesis
    Rahman, Mohammed Shamim
    Roy, David
    Brecker, Stephen J.
    [J]. HEART, 2013, 99 (03) : 217 - 218