An instrumental design for the analysis of heavy metals in solid samples (certified reference materials, river sediments, cements) by direct graphite furnace atomic absorption spectroscopy (SSGF-AAS) is presented and outlined. A high performance atomic absorption spectrometer with a D2-background corrector and a transversely heated graphite atomizer was modified. Solid sampling was achieved by a mechanical module combined with an ultra microbalance. Cadmium, lead and chromium in different samples (sample weights between 20–400 μg) have been determined in the μg/g- to ng/g-range with the graphite-platform technique. Different ways of calibration and inhomogeneity problems are discussed. The precision of SSGF-AAS is equal to the precision of the conventional AAS-technique with chemical digestion (microwave digestion system, Zeeman-AAS). It is shown that SSGF-AAS is a reasonable alternative to the conventional technique for selected analytical problems.
引用
收藏
页码:132 / 137
页数:5
相关论文
共 50 条
  • [1] Direct analysis of solid samples by graphite furnace atomic absorption spectrometry with a transversely heated graphite atomizer and D-2-background correction system (SS GF-AAS)
    Nowka, R
    Muller, H
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 359 (02): : 132 - 137
  • [2] Cadmium and Chromium Determination in Herbal Tinctures Employing Direct Analysis by Graphite Furnace Atomic Absorption Spectrometry (GF-AAS)
    Lopes, Agatha Merilin de Oliveira
    Chellini, Paula Rocha
    de Sousa, Rafael Arromba
    ANALYTICAL LETTERS, 2020, 53 (13) : 2096 - 2110
  • [3] Direct determination of phosphorus in animal and vegetable oils and fats by graphite furnace atomic absorption spectrometry (GF-AAS)
    Baglio, D.
    Folegatti, L.
    RIVISTA ITALIANA DELLE SOSTANZE GRASSE, 2012, 89 (03): : 152 - 160
  • [4] Determination of cadmium in lichens by solid sampling graphite furnace atomic absorption spectrometry (SS-GF-AAS)
    Pavel Coufalík
    Antonín Uher
    Ondřej Zvěřina
    Josef Komárek
    Environmental Monitoring and Assessment, 2020, 192
  • [5] Determination of cadmium in lichens by solid sampling graphite furnace atomic absorption spectrometry (SS-GF-AAS)
    Coufalik, Pavel
    Uher, Antonin
    Zverina, Ondrej
    Komarek, Josef
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2020, 192 (04)
  • [6] Simultaneous determination of lead, cadmium, nickel and chromium by graphite furnace atomic absorption spectrometry (GF-AAS)
    Gottelt, U
    Henrion, G
    Kalahne, R
    Stoyke, M
    NAHRUNG-FOOD, 1997, 41 (01): : 53 - 54
  • [7] Direct determination of some metals in extra virgin olive oils by graphite furnace atomic absorption (GF-AAS)
    Baglio, D.
    Folegatti, L.
    RIVISTA ITALIANA DELLE SOSTANZE GRASSE, 2013, 90 (03): : 153 - 162
  • [8] ON THE DIRECT ANALYSIS OF SOLID SAMPLES BY GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY
    BAXTER, DC
    FRECH, W
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 337 (03): : 253 - 263
  • [9] Simultaneous determination of the toxicological relevant elements lead, cadmium and nickel by graphite furnace atomic absorption spectrometry (GF-AAS)
    Gottelt, U
    Henrion, G
    Kalahne, R
    Stoyke, M
    NAHRUNG-FOOD, 1996, 40 (02): : 87 - 92
  • [10] Determination of aluminium in nickel-based alloy samples using a longitudinal Zeeman-effect correction transversely heated graphite atomizer and a deuterium background correction end-heated graphite atomizer in electrothermal atomic absorption spectrometry
    Chang, SI
    Liu, HM
    Tsai, SJJ
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (10) : 1123 - 1131