Comparison of real beat-to-beat signals with commercially available 4 Hz sampling on the evaluation of foetal heart rate variability

被引:0
|
作者
Hernâni Gonçalves
Antónia Costa
Diogo Ayres-de-Campos
Cristina Costa-Santos
Ana Paula Rocha
João Bernardes
机构
[1] Center for Research in Health Technologies and Information Systems (CINTESIS),Department of Obstetrics and Gynecology, Faculty of Medicine
[2] Faculty of Medicine,Department of Obstetrics and Gynecology
[3] University of Porto,Departamento de Matemática, Faculdade de Ciências
[4] University of Porto,undefined
[5] Hospital São João,undefined
[6] Instituto de Engenharia Biomédica (INEB),undefined
[7] Universidade do Porto,undefined
[8] Centro de Matemática da Universidade do Porto,undefined
关键词
Foetal heart rate; Foetal monitoring; Cardiotocography; Signal processing; Electrocardiography;
D O I
暂无
中图分类号
学科分类号
摘要
Evaluation of foetal heart rate (FHR) variability is an essential part of foetal monitoring, but a precise quantification of this parameter depends on the quality of the signal. In this study, we compared real FHR beat-to-beat signals with 4 Hz sampling provided by commercial foetal monitors on linear and nonlinear indices and analysed their clinical implications. Simultaneous acquisition of beat-to-beat signals and their 4 Hz sampling rate counterparts was performed using a scalp electrode, during the last hour of labour in 21 fetuses born with an umbilical artery blood (UAB) pH ≥ 7.20 and 6 born with an UAB pH < 7.20. For each case, the first and last 10 min segments were analysed, using time and frequency domain linear, and nonlinear FHR indices, namely mean FHR, low frequency, high frequency, approximate, sample and multiscale entropy. Significant differences in variability indices were found between beat-to-beat and 4 Hz sampled signals, with a lesser effect seen with 2 Hz sampling. These differences did not affect physiological changes observed during labour progression, such as decreased entropy and linear time domain indices, and increased frequency domain indices. However, significant differences were found in the discrimination between fetuses born with different UAB pHs, with beat-to-beat sampling providing better results in linear indices and 4 Hz sampling better results in entropy indices. In conclusion, different FHR sampling frequencies can significantly affect the quantification of variability indices. This needs to be taken into account in the interpretation of FHR variability and in the development of new equipment.
引用
收藏
页码:665 / 676
页数:11
相关论文
共 50 条
  • [1] Comparison of real beat-to-beat signals with commercially available 4 Hz sampling on the evaluation of foetal heart rate variability
    Goncalves, Hernani
    Costa, Antonia
    Ayres-de-Campos, Diogo
    Costa-Santos, Cristina
    Rocha, Ana Paula
    Bernardes, Joao
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2013, 51 (06) : 665 - 676
  • [2] BEAT-TO-BEAT AND PHASIC HEART-RATE VARIABILITY IN ADULTS
    BELL, PS
    GRADMAN, AH
    ROSS, AM
    [J]. CLINICAL RESEARCH, 1978, 26 (03): : A219 - A219
  • [3] Effect of posture and isoproterenol on beat-to-beat heart rate and QT variability
    Yeragani, VK
    Pohl, R
    Jampala, VC
    Balon, R
    Kay, J
    Igel, G
    [J]. NEUROPSYCHOBIOLOGY, 2000, 41 (03) : 113 - 123
  • [4] FETAL HEART-RATE BEAT-TO-BEAT VARIABILITY IN UNCOMPLICATED LABOR
    ZIMMER, EZ
    DIVON, MY
    VADASZ, A
    [J]. GYNECOLOGIC AND OBSTETRIC INVESTIGATION, 1988, 25 (02) : 80 - 82
  • [5] Multivariate spectral analysis of the beat-to-beat sampled cortical NIRS-signals and the heart rate variability
    Scholz, UJ
    Kohl, M
    Nolte, C
    Hennig, C
    Villringer, A
    [J]. PHOTON PROPAGATION IN TISSUES IV, PROCEEDINGS, 1998, 3566 : 106 - 111
  • [6] A NEW MODALITY IN NONSTRESS TESTING - EVALUATION OF BEAT-TO-BEAT FETAL HEART-RATE-VARIABILITY
    LAUERSEN, NH
    WILSON, KH
    BILEK, A
    RAO, VSJ
    KURKULOS, M
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1981, 141 (05) : 521 - 526
  • [7] PATTERNS OF BEAT-TO-BEAT HEART-RATE-VARIABILITY IN ADVANCED HEART-FAILURE
    WOO, MA
    STEVENSON, WG
    MOSER, DK
    TRELEASE, RB
    HARPER, RM
    [J]. AMERICAN HEART JOURNAL, 1992, 123 (03) : 704 - 710
  • [8] RELATION OF BEAT-TO-BEAT VARIABILITY TO HEART-RATE IN NORMAL SLEEPING INFANTS
    MAZZA, NM
    EPSTEIN, MAF
    HADDAD, GG
    LAW, HS
    MELLINS, RB
    EPSTEIN, RA
    [J]. PEDIATRIC RESEARCH, 1980, 14 (03) : 232 - 235
  • [9] Beat-to-Beat Heart Rate and Blood Pressure Variability and Hypertensive Disease in Pregnancy
    Flood, Pamela
    McKinley, Paula
    Monk, Catherine
    Muntner, Paul
    Colantonio, Lisandro D.
    Goetzl, Laura
    Hatch, Maureen
    Sloan, Richard P.
    [J]. AMERICAN JOURNAL OF PERINATOLOGY, 2015, 32 (11) : 1050 - 1058
  • [10] ANALYSIS OF HEART-RATE AND BEAT-TO-BEAT VARIABILITY - INTERVAL DIFFERENCE INDEX
    VANGEIJN, HP
    JONGSMA, HW
    DEHAAN, J
    ESKES, TKAB
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1980, 138 (03) : 246 - 252