Cost–benefit analysis of retrofit of high-intensity discharge factory lighting with energy-saving alternatives

被引:0
|
作者
Daniel J. Preston
Keith A. Woodbury
机构
[1] The University of Alabama,Alabama Industrial Assessment Center
[2] The University of Alabama,Alabama Industrial Assessment Center
来源
Energy Efficiency | 2013年 / 6卷
关键词
Industrial lighting; Lighting retrofit; Metal halide; Industrial lighting efficiency;
D O I
暂无
中图分类号
学科分类号
摘要
Due to increased concern about overall energy costs and the appearance of efficient and inexpensive lighting system alternatives, factories and plants with high-intensity discharge (HID) lighting are forced to consider retrofit with more modern, energy-efficient lighting. The decision is complicated from an economic perspective, and there is a lack of information readily available on the topic. This study provides an analysis of the replacement by retrofit of common probe-start metal halide and high-pressure sodium industrial lighting systems. Retrofit options considered include the more recent pulse-start metal halide lamps and a range of T5 high output and T8 fluorescent lamp configurations. Recent data on lighting system pricing, labor and energy costs, and time required for tasks are reported. The results generated include savings, payback period, and net present value for many retrofit options, as well as the change in energy consumption, carbon footprint, and lumen output for each retrofit. Effects of varying rate of return and daily duration of operation are considered. Based on change in lumen output, payback period, net present value, and comparison of lighting quality, one or two options are recommended from the overall retrofit options considered. A fluorescent retrofit is recommended for each of the HID initial scenarios considered. The payback period is no more than 3 years in any recommended case. The focus of this study is on the potential energy and cost savings, and some proposed solutions may, or may not, be acceptable due to lack of illuminance uniformity.
引用
收藏
页码:255 / 269
页数:14
相关论文
共 50 条
  • [1] Cost-benefit analysis of retrofit of high-intensity discharge factory lighting with energy-saving alternatives
    Preston, Daniel J.
    Woodbury, Keith A.
    ENERGY EFFICIENCY, 2013, 6 (02) : 255 - 269
  • [2] Lighting Energy-Saving Design for Industrial Factory Building
    Lian Yanfang
    GREEN POWER, MATERIALS AND MANUFACTURING TECHNOLOGY AND APPLICATIONS III, PTS 1 AND 2, 2014, 484-485 : 737 - 741
  • [3] HIGH-INTENSITY ENERGY-SAVING DRYING OF CELLULOSE FIBROUS MATERIALS
    Khasanshin, Ruslan R.
    Safin, Ruslan R.
    Kaynov, Pavel A.
    Shaikhutdinova, Aigul R.
    Safin, Rushan G.
    WATER RESOURCES, FOREST, MARINE AND OCEAN ECOSYSTEMS CONFERENCE PROCEEDINGS, SGEM 2016, VOL II, 2016, : 533 - 540
  • [4] The energy-saving characteristic of silica gel regeneration with high-intensity ultrasound
    Zhang, Weijiang
    Yao, Ye
    He, Beixing
    Wang, Rongshun
    APPLIED ENERGY, 2011, 88 (06) : 2146 - 2156
  • [5] BRIGHT LIGHTS + HIGH-INTENSITY DISCHARGE LIGHTING
    LEFER, H
    PROGRESSIVE ARCHITECTURE, 1976, 57 (10): : 92 - 97
  • [6] Dimming Characteristics of Large-scale High-Intensity-Discharge (HID) Lamp Lighting Networks using a Central Energy-Saving System
    Yan, Wei
    Hui, S. Y. R.
    CONFERENCE RECORD OF THE 2006 IEEE INDUSTRY APPLICATIONS CONFERENCE, FORTY-FIRST IAS ANNUAL MEETING, VOL 1-5, 2006, : 1090 - 1098
  • [7] Explainable Artificial-Intelligence-Based Power Conservation: A Benefit Analysis of Energy-Saving Artistic Lighting in Museums
    Wang, Ruoyan
    IEEE SYSTEMS MAN AND CYBERNETICS MAGAZINE, 2025, 11 (01): : 48 - 56
  • [8] The Energy and Financial Impacts of High-Intensity Discharge Lighting System Component Selection and Luminaire Maintenance in Industrial Lighting Applications
    Flory, Isaac L., IV
    Rahman, Saifur
    LEUKOS, 2008, 5 (02) : 119 - 138
  • [9] The Analysis of Natural Lighting Simulation and Study on Energy Saving in Cigarette Factory
    Zhu, Tao
    Li, Rui
    Li, Chengmeng
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 895 - 901
  • [10] TABLE-TENNIS UNDER HIGH-INTENSITY DISCHARGE (HID) LIGHTING
    REA, MS
    OUELLETTE, MJ
    JOURNAL OF THE ILLUMINATING ENGINEERING SOCIETY, 1988, 17 (01): : 29 - 35