A new registration algorithm of electronic portal imaging devices images based on the automatic detection of bone edges during radiotherapy

被引:0
|
作者
Cheng Chen
Chaoyan Wu
Yahua Zhong
Conghua Xie
Yunfeng Zhou
Hui Liu
Jun Zhang
Jiuling Sheng
Dazheng Jiang
Hongli Zhao
Haijun Yu
机构
[1] Zhongnan Hospital of Wuhan University,Department of Radiation and Medical Oncology, Hubei Province Cancer Clinical Study Center, Hubei Key Laboratory of Tumor Biological Behaviors
[2] Zhongnan Hospital of Wuhan University,Department of Traditional Chinese Medicine
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The precision and efficiency of the registration of megavolt-level electronic portal imaging devices (EPID) images with the naked eye in the orthogonal window are reduced. This study aims to develop a new registration algorithm with enhanced accuracy and efficiency. Ten setup errors with different translation and rotation were simulated with the phantom. For each error, one set of simulated computer tomography images and EPID images were acquired and registered with the traditional and the new method. The traditional method was performed by two senior physicists with the Varian Offline Review software. The new method is basing on the comparison of the precise contours of the same bone structure in the digital reconstruction radiography images and the EPID images, and the contours were fitted with an automatic edge detection algorithm based on gradient images. The average error of the new method was decreased by 44.44%, 28.33%, 49.09% in the translation of X, Y, and Z axes (The traditional vs. the new: X axes, 0.45 mm vs. 0.25 mm; Y axes, 0.75 mm vs. 0.35 mm; Z axes, 0.55 mm vs. 0.28 mm), 42.86% and 40.48% in the rotation of X and Z axes (The traditional vs. the new: X axes, 0.49° vs. 0.28°; Z axes, 0.42° vs. 0.25°), respectively. The average elapsed time in the new method was reduced by 11.14% (The traditional vs. the new: 44 s vs. 39.1 s). The new registration method has significant advantages of accuracy and efficiency compared with the traditional method.
引用
收藏
相关论文
共 11 条
  • [1] A new registration algorithm of electronic portal imaging devices images based on the automatic detection of bone edges during radiotherapy
    Chen, Cheng
    Wu, Chaoyan
    Zhong, Yahua
    Xie, Conghua
    Zhou, Yunfeng
    Liu, Hui
    Zhang, Jun
    Sheng, Jiuling
    Jiang, Dazheng
    Zhao, Hongli
    Yu, Haijun
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [2] A new approach in the design of electronic portal imaging devices for portal dosimetry in radiotherapy
    Badel, J. -N.
    Partouche-Sebban, D.
    Abraham, I.
    Carrie, C.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (06): : 644 - 653
  • [3] A new approach in the design of electronic portal imaging devices for portal dosimetry in radiotherapy
    Badel, J. N.
    Partouche-Sebban, D.
    Abraham, I.
    Carrie, C.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S216 - S216
  • [4] A new algorithm for the registration of portal images to planning images in the verification of radiotherapy, as validated in prostate treatments
    Jobse, M
    Davelaar, J
    Hendriks, E
    Kattevilder, R
    Reiber, H
    Stoel, B
    MEDICAL PHYSICS, 2003, 30 (09) : 2274 - 2281
  • [5] Radiotherapy delivery error detection with electronic portal imaging device (EPID)-based in vivo dosimetry
    Yang, Xueying
    Geng, Lisheng
    Huang, David
    Li, Kaiwen
    Zhuang, Hongqing
    Cai, Jing
    Yang, Ruijie
    CHINESE MEDICAL JOURNAL, 2023, 136 (08) : 998 - 1000
  • [6] Radiotherapy delivery error detection with electronic portal imaging device (EPID)-based in vivo dosimetry
    Yang Xueying
    Geng Lisheng
    Huang David
    Li Kaiwen
    Zhuang Hongqing
    Cai Jing
    Yang Ruijie
    中华医学杂志英文版, 2023, 136 (08)
  • [7] In silico study of the electronic portal imaging devices sensitivity to parotid glands shrinkage during radiotherapy for nasopharyngeal cases
    Alzahrani H.M.
    Journal of Umm Al-Qura University for Applied Sciences, 2024, 10 (2): : 279 - 289
  • [8] Effect of flat-fielding on intensity-based registrations using electronic portal imaging devices (EPIDs) in radiotherapy
    Wu, J
    Samant, S
    MEDICAL PHYSICS, 2004, 31 (06) : 1729 - 1729
  • [9] Reconstruction of four-dimensional computed tomography images during treatment time using electronic portal imaging device images based on a dynamic 2D/3D registration
    Nakamoto, T.
    Arimura, H.
    Hirose, T. A.
    Ohga, S.
    Umezu, Y.
    Nakamura, Y.
    Honda, H.
    Sasaki, T.
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [10] Simulation of pseudo-CT images based on deformable image registration of ultrasound images: A proof of concept for transabdominal ultrasound imaging of the prostate during radiotherapy
    van der Meer, Skadi
    Camps, Saskia M.
    van Elmpt, Wouter J. C.
    Podesta, Mark
    Sanches, Pedro Gomes
    Vanneste, Ben G. L.
    Fontanarosa, Davide
    Verhaegen, Frank
    MEDICAL PHYSICS, 2016, 43 (04) : 1913 - 1920