Analysis of Th and U in thorium-based mixed-oxide fuel using wavelength dispersive X-ray fluorescence spectrometer

被引:0
|
作者
A. Pandey
S. Dhara
F. A. Khan
A. Kelkar
Pradeep Kumar
R. B. Bhatt
P. G. Behere
机构
[1] Bhabha Atomic Research Centre,Advanced Fuel Fabrication Facility
[2] Bhabha Atomic Research Centre,Fuel Chemistry Division
[3] Homi Bhabha National Institute,Integrated Fuel Fabrication Facility
[4] Bhabha Atomic Research Centre,undefined
关键词
Uranium; Thorium; Mixed oxides; WDXRF; Nuclear fuel;
D O I
暂无
中图分类号
学科分类号
摘要
A precise and accurate compositional characterization methodology using wavelength dispersive X-ray fluorescence (WDXRF) spectrometry for mixed oxide nuclear fuels is reported. The methodology involves pelletization of standards and samples. The calibration plots were made by plotting the percent intensity of analyte X-ray lines against their amount percent. The relative standard deviation were 0.4% and 0.25%, respectively for uranium and thorium, having U ranging from 2.85 to 4.2 (wt%). The analytical results were compared with chemical analysis method and were in good agreement. The developed WDXRF method is non-destructive, fast and better in comparison to chemical analysis methods.
引用
下载
收藏
页码:775 / 781
页数:6
相关论文
共 50 条
  • [1] Analysis of Th and U in thorium-based mixed-oxide fuel using wavelength dispersive X-ray fluorescence spectrometer
    Pandey, A.
    Dhara, S.
    Khan, F. A.
    Kelkar, A.
    Kumar, Pradeep
    Bhatt, R. B.
    Behere, P. G.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2019, 319 (03) : 775 - 781
  • [2] Novel wavelength-dispersive X-ray fluorescence spectrometer
    Firsov, A.
    Erko, A.
    Senf, F.
    Rehanek, J.
    Brzhezinskaya, M.
    Wernet, R. Mitzner Ph
    Foehlisch, A.
    11TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI 2012), 2013, 425
  • [3] WAVELENGTH DISPERSIVE X-RAY FLUORESCENCE ANALYSIS USING SYNCHROTRON RADIATION
    Ohashi, Kazutaka
    Iide, Atsuo
    Gohshi, Yohichi
    ANALYTICAL SCIENCES, 1991, 7 : 361 - 364
  • [4] Determination of inorganic elements in milk powder using wavelength dispersive X-ray fluorescence spectrometer
    Habib-Ur-Rehman
    Rehana, Ishrat
    Yawar, Wasim
    INTERNATIONAL JOURNAL OF DAIRY TECHNOLOGY, 2012, 65 (01) : 98 - 103
  • [5] A Probable Improvement of Wavelength Dispersive X-Ray Fluorescence Spectrometer for Steel Making
    Kawai, Jun
    ISIJ INTERNATIONAL, 2022, 62 (05) : 867 - 870
  • [6] Determination of the emission spectrum of an X-ray tube of a wavelength-dispersive series X-ray fluorescence spectrometer
    Oskolok, K.V.
    Monogarova, O.V.
    Journal of Analytical Chemistry, 2008, 63 (12): : 1176 - 1181
  • [7] Determination of the emission spectrum of an X-ray tube of a wavelength-dispersive series X-ray fluorescence spectrometer
    Oskolok, K. V.
    Monogarova, O. V.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2008, 63 (12) : 1176 - 1181
  • [8] Determination of the emission spectrum of an X-ray tube of a wavelength-dispersive series X-ray fluorescence spectrometer
    K. V. Oskolok
    O. V. Monogarova
    Journal of Analytical Chemistry, 2008, 63 : 1176 - 1181
  • [9] Calibration of wavelength-dispersive X-ray spectrometer for standardless analysis
    Sitko, R
    Zawisza, B
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2005, 60 (01) : 95 - 100
  • [10] Determination of water content in silica nanopowder using wavelength-dispersive X-ray fluorescence spectrometer
    Choi, Yong Suk
    Kim, Jong-Yun
    Yoon, Suk Bon
    Song, Kyuseok
    Kim, Young Jin
    MICROCHEMICAL JOURNAL, 2011, 99 (02) : 332 - 338