Mechanical behaviour of alginate film with embedded voids under compression-decompression cycles

被引:0
|
作者
Arindam Banerjee
Somenath Ganguly
机构
[1] Indian Institute of Technology,Department of Chemical Engineering
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Voids of 300 µm diameter were embedded uniformly as monolayer in alginate gel film using a fluidic device. Voids of these dimensions in biopolymer gel film are desired for better transport of bioactive species and cell colonization in engineered tissues. In this article, the role of embedded voids in reducing compressive stress, hysteresis, and time scale of reheal vis-a-vis expulsion of pore fluid and its reabsorption upon reversal of load are reviewed. The cyclic loading was conducted with varying amplitude and frequency. The irreversible changes, if any in the gel structure under extreme compression were analyzed. The rate of expulsion of aqueous phase directly relates to the permeability of the gel film that is estimated here using simplified momentum and volumetric balance equations. The decrease in permeability with deformation is analyzed further, and the contribution of voids in this regard is discussed.
引用
收藏
相关论文
共 50 条
  • [1] Mechanical behaviour of alginate film with embedded voids under compression-decompression cycles
    Banerjee, Arindam
    Ganguly, Somenath
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [2] Mechanical behaviour of a hydrogel film with embedded voids under the tensile load
    Banerjee, Arindam
    Patra, Subhajit
    Ganguly, Somenath
    JOURNAL OF SOL-GEL SCIENCE AND TECHNOLOGY, 2018, 87 (03) : 665 - 675
  • [3] Mechanical behaviour of a hydrogel film with embedded voids under the tensile load
    Arindam Banerjee
    Subhajit Patra
    Somenath Ganguly
    Journal of Sol-Gel Science and Technology, 2018, 87 : 665 - 675
  • [4] Determination of elasticity of gels by successive compression-decompression cycles
    Kaletunc, G.
    Normand, M. D.
    Nussinovitch, A.
    Peleg, M.
    FOOD HYDROCOLLOIDS, 1991, 5 (03) : 237 - 247
  • [5] AUTOMATIC MECHANICAL DEVICE TO STANDARDIZE ACTIVE COMPRESSION-DECOMPRESSION CPR
    WENZEL, V
    FUERST, RS
    IDRIS, AH
    BANNER, MJ
    RUSH, WJ
    ORBAN, DJ
    ANNALS OF EMERGENCY MEDICINE, 1995, 25 (03) : 386 - 389
  • [6] Effect of different compression-decompression cycles on haemodynamics during ACD-CPR in pigs
    Sunde, K
    Wik, L
    Naess, PA
    Ilebekk, A
    Nicolaysen, G
    Steen, PA
    RESUSCITATION, 1998, 36 (02) : 123 - 131
  • [7] Disorder-to-order transition in selenium under cyclic compression-decompression
    Dong, Xingbang
    Shi, Kaiyuan
    Zhang, Jiaqing
    Fu, Wenbo
    Du, Zhaoxu
    Yang, Haotian
    Kong, Jun
    Qiao, Pu
    Zhang, Xin
    Su, Lei
    PHYSICAL REVIEW B, 2025, 111 (06)
  • [8] Quality of mechanical, manual standard and active compression-decompression CPR on the arrest site and during transport in a manikin model
    Sunde, K
    Wik, L
    Steen, PA
    RESUSCITATION, 1997, 34 (03) : 235 - 242
  • [9] A COMPARISON OF MECHANICAL, STANDARD AND ACTIVE COMPRESSION-DECOMPRESSION CPR IN OUT-OF-HOSPITAL CARDIAC-ARREST PATIENTS
    RIVERS, EP
    BOCZAR, ME
    SMITHLINE, HA
    LURIE, KG
    NOWAK, RM
    CIRCULATION, 1993, 88 (04) : 193 - 193
  • [10] Mechanical behaviour of hazelnut under compression loading
    Güner, M
    Dursun, E
    Dursun, IG
    BIOSYSTEMS ENGINEERING, 2003, 85 (04) : 485 - 491