Theoretical and experimental results are presented on the error of measurement for cell dry mass, which is determined by integrating the distribution of the phase of the transmitted wavefront. The phase distribution is measured with a computerized Linnik interference microscope.
引用
收藏
页码:412 / 416
页数:4
相关论文
共 50 条
  • [1] Error in measuring dry cell mass with a computerized interference microscope
    Levin, GG
    Kovalev, AA
    Minaev, VL
    Sukhorukov, KA
    MEASUREMENT TECHNIQUES, 2004, 47 (04) : 412 - 416
  • [2] Application of computerized interference microscope for monitoring oscillations of dry cell weight and morphology of the living cells
    Levin, GG
    Bulygin, TV
    Kalinin, EV
    Vishnyakov, GN
    OPTICAL DIAGNOSITICS OF LIVING CELLS IV, 2001, 4260 : 149 - 154
  • [3] THE USE OF THE INTERFERENCE MICROSCOPE TO DETERMINE DRY MASS IN LIVING CELLS AND AS A QUANTITATIVE CYTOCHEMICAL METHOD
    DAVIES, HG
    WILKINS, MHF
    CHAYEN, J
    LACOUR, LF
    QUARTERLY JOURNAL OF MICROSCOPICAL SCIENCE, 1954, 95 (03): : 271 - &
  • [4] An automated interference microscope for measuring dynamic objects
    Levin, G. G.
    Vishnyakov, G. N.
    Minaev, V. L.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2013, 56 (06) : 686 - 690
  • [5] An automated interference microscope for measuring dynamic objects
    G. G. Levin
    G. N. Vishnyakov
    V. L. Minaev
    Instruments and Experimental Techniques, 2013, 56 : 686 - 690
  • [6] DETERMINATION OF DRY MASS OF NERVOUS AND GLIAL CELL NUCLEI BY INTERFERENCE MICROSCOPY
    VIOLA, MP
    PUCCINELLI, E
    EXPERIENTIA, 1965, 21 (06): : 320 - +
  • [7] DRY MASS OF EPITHELIAL CELLS FROM VAGINA OF MICE IN COURSE OF OESTRUS CYCLE MEASURED BY INTERFERENCE MICROSCOPE
    OSTROWSKI, K
    SAWICKI, W
    DARZYNKIEWICZ, Z
    STOCKA, Z
    ACTA BIOCHIMICA POLONICA, 1964, 11 (2-3) : 99 - +
  • [8] Exploratory calibration for universal measuring microscope indicator error
    Shen, Ze-Hong
    Huadong Chuanbo Gongye Xueyuan Xuebao/Journal of East China Shipbuilding Institute, 2001, 15 (06): : 83 - 85
  • [9] Modulation interference microscope as a tool for measuring the linear dimensions of nanostructures
    A. G. Andreev
    S. N. Grigoriev
    E. V. Romash
    S. V. Bushuev
    P. S. Ignatiev
    A. V. Loparev
    K. V. Indukaev
    P. A. Osipov
    Measurement Techniques, 2012, 55 : 542 - 545
  • [10] ACCURACY IN MEASURING DEPTH OF CALIBRATION GROOVES USING AN INTERFERENCE MICROSCOPE
    HILLMANN, W
    ECKOLT, K
    F&M-FEINWERKTECHNIK & MESSTECHNIK, 1975, 83 (07): : 318 - 321