The aim of this study was to compare computerized automatic methods to detect the ventilatory threshold (VT). Thirty apparently healthy and physically active volunteers [22.5 (6.5) years; 1.72 (0.08) m; 71.9 (8.5) kg] were submitted to a progressive and maximal cycle exercise. The gas exchange was monitored breath-by-breath with a fast gas analyser. The VT and respiratory compensation (RC) were automatically detected based on the respiratory exchange ratio, the ventilatory equivalent for O2 and the ventilatory equivalent for CO2, pulmonary ventilation, end-tidal PO2 and PCO2, and v-slope. In addition, VT and RC were also determined independently by visual inspection by two experienced investigators, and the results were compared with those of the automatic procedures. The automatic VT averaged 77% of the maximal V̇O2 and the RC 88%. The agreement between the experienced observers was very close [mean difference: 44.4 (16.1) ml, r=0.94, not significant]. Data were expressed as the mean value together with the standard deviation in each case. The automatic and visual inspection procedures did not present significant differences, resulting in 29.6 (29.6) ml with a reliability of r=0.86. All methods were significantly correlated for VT and RC (r=0.93 on average, P<0.01). ANOVA did not show differences between either the VT methods (P=0.131) or the RC methods (P=0.41). In conclusion, the present study has compared several simultaneous breath-by-breath ergospirometric methods that are used to describe the anaerobic threshold, showing high confidence when compared to visual inspection. No statistical differences were found between the VT and RC techniques for physically active subjects indicating that these methods may be equally effectively employed.
引用
收藏
页码:315 / 324
页数:9
相关论文
共 50 条
  • [1] Comparison of computerized methods for detecting the ventilatory thresholds
    Santos, EL
    Giannella-Neto, A
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2004, 93 (03) : 315 - 324
  • [2] A REVIEW OF BLOOD LACTATE AND VENTILATORY METHODS OF DETECTING TRANSITION THRESHOLDS
    ANDERSON, GS
    RHODES, EC
    SPORTS MEDICINE, 1989, 8 (01) : 43 - 55
  • [3] USING SMOOTHING SPLINES FOR DETECTING VENTILATORY THRESHOLDS
    SHERRILL, DL
    ANDERSON, SJ
    SWANSON, G
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1990, 22 (05): : 684 - 689
  • [4] Ventilatory Thresholds Determined from HRV: Comparison of 2 Methods in Obese Adolescents
    Quinart, S.
    Mourot, L.
    Negre, V.
    Simon-Rigaud, M. -L.
    Nicolet-Guenat, M.
    Bertrand, A. -M.
    Meneveau, N.
    Mougin, F.
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2014, 35 (03) : 203 - 208
  • [5] Comparison Of Work Rates At Ventilatory, Lactate, And pH Thresholds
    Morris, David M.
    Woodall, Mark W.
    Fairbrother, Kimberly R.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2010, 42 (05): : 750 - 750
  • [6] Comparison Of Ventilatory Thresholds Via V-slope Method To Lactate Thresholds With NIRS
    Hutchison, Randolph E.
    Klapthor, Gibson A. E.
    Knowles, Kristine E.
    Edwards, Karlee S.
    Humes, Kelly A.
    Mocko, Gregory M.
    Vahidi, Ardalan
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2016, 48 (05) : 107 - 108
  • [7] Perceived exertion threshold: Comparison with ventilatory thresholds and critical power
    Nakamura, F. Y.
    Okuno, N. M.
    Perandini, L. A. B.
    de Oliveira, F. R.
    Buchheit, M.
    Simoes, H. G.
    SCIENCE & SPORTS, 2009, 24 (3-4) : 196 - 201
  • [8] A Comparison of Conventional and Computerized Cephalometric Methods
    Celikoglu, Mevlut
    Kilkis, Dogan
    TURKISH JOURNAL OF ORTHODONTICS, 2012, 25 (02) : 105 - 112
  • [9] COMPARISON OF OBJECTIVE METHODS FOR DETERMINING VENTILATORY THRESHOLD
    FUKUBA, Y
    MUNAKA, M
    USUI, S
    SASAHARA, H
    JAPANESE JOURNAL OF PHYSIOLOGY, 1988, 38 (02): : 133 - 144
  • [10] Reliability of assessments of ventilatory thresholds
    Prud'Homme, D.
    Bouchard, C.
    Leblance, C.
    Landry, F.
    Lortie, G.
    Boulay, M. R.
    JOURNAL OF SPORTS SCIENCES, 1984, 2 (01) : 13 - 24