FDG Whole-Body PET/MRI in Oncology: a Systematic Review

被引:27
|
作者
Kwon H.W. [1 ]
Becker A.-K. [2 ]
Goo J.M. [3 ]
Cheon G.J. [4 ]
机构
[1] Department of Nuclear Medicine, Soonchunhyang University Hospital, Cheonan
[2] Rheinisch Westfälische Technische Hochschule Aachen University, Aachen
[3] Department of Radiology, Seoul National University College of Medicine, Seoul
[4] Department of Nuclear Medicine, Seoul National University College of Medicine, 101 Daehang-ro, Jongno-gu, Seoul
关键词
FDG; Oncology; PET/MRI; Positron emission tomography/magnetic resonance imaging;
D O I
10.1007/s13139-016-0411-3
中图分类号
学科分类号
摘要
The recent advance in hybrid imaging techniques enables offering simultaneous positron emission tomography (PET)/magnetic resonance imaging (MRI) in various clinical fields. 18F-fluorodeoxyglucose (FDG) PET has been widely used for diagnosis and evaluation of oncologic patients. The growing evidence from research and clinical experiences demonstrated that PET/MRI with FDG can provide comparable or superior diagnostic performance more than conventional radiological imaging such as computed tomography (CT), MRI or PET/CT in various cancers. Combined analysis using structural information and functional/molecular information of tumors can draw additional diagnostic information based on PET/MRI. Further studies including determination of the diagnostic efficacy, optimizing the examination protocol, and analysis of the hybrid imaging results is necessary for extending the FDG PET/MRI application in clinical oncology. © 2016, Korean Society of Nuclear Medicine.
引用
收藏
页码:22 / 31
页数:9
相关论文
共 50 条
  • [1] Whole-body MRI and FDG-PET/CT imaging diagnostics in oncology
    Schmidt, G. P.
    Haug, A.
    Reiser, M. F.
    Rist, C.
    RADIOLOGE, 2010, 50 (04): : 329 - 338
  • [2] WHOLE-BODY FDG-PET ONCOLOGY ATLAS
    BROWN, CV
    KHONSARY, SA
    BHATTATHIRY, M
    ROPCHAN, JR
    FARAHI, JB
    QUINONES, N
    RIBE, JY
    COLOURIS, GC
    GLASS, EC
    COYLE, JJ
    MANDELKERN, MA
    BLAHD, WH
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (05) : P273 - P273
  • [3] Whole-Body PET/MRI Applications in Pediatric Oncology
    States, Lisa J.
    Reid, Janet R.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 215 (03) : 713 - 725
  • [4] Diagnostic accuracy of whole-body PET/MRI and whole-body PET/CT for TNM staging in oncology
    Philipp Heusch
    Felix Nensa
    Benedikt Schaarschmidt
    Rupika Sivanesapillai
    Karsten Beiderwellen
    Benedikt Gomez
    Jens Köhler
    Henning Reis
    Verena Ruhlmann
    Christian Buchbender
    European Journal of Nuclear Medicine and Molecular Imaging, 2015, 42 : 42 - 48
  • [5] Diagnostic accuracy of whole-body PET/MRI and whole-body PET/CT for TNM staging in oncology
    Heusch, Philipp
    Nensa, Felix
    Schaarschmidt, Benedikt
    Sivanesapillai, Rupika
    Beiderwellen, Karsten
    Gomez, Benedikt
    Koehler, Jens
    Reis, Henning
    Ruhlmann, Verena
    Buchbender, Christian
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 (01) : 42 - 48
  • [6] Whole-body MRI in oncology: A comprehensive review
    Vulasala, Sai Swarupa
    Virarkar, Mayur
    Karbasian, Niloofar
    Calimano-Ramirez, Luis F.
    Daoud, Taher
    Amini, Behrang
    Bhosale, Priya
    Javadi, Sanaz
    CLINICAL IMAGING, 2024, 108
  • [7] Comparison between whole-body MRI and Fluorine-18-Fluorodeoxyglucose PET or PET/CT in oncology: a systematic review
    Ciliberto, Mario
    Maggi, Fabio
    Treglia, Giorgio
    Padovano, Federico
    Calandriello, Lucio
    Giordano, Alessandro
    Bonomo, Lorenzo
    RADIOLOGY AND ONCOLOGY, 2013, 47 (03) : 206 - 218
  • [8] Whole-Body [18F]-FDG-PET/MRI for Oncology: A Consensus Recommendation
    Umutlu, Lale
    Beyer, Thomas
    Grueneisen, Johannes Stefan
    Rischpler, Christoph
    Quick, Harald H.
    Veit-Haibach, Patrick
    Eiber, Matthias
    Purz, Sandra
    Antoch, Gerald
    Gatidis, Sergios
    Nikolaou, Konstantin
    Schaefer, Juergen F.
    Rausch, Ivo
    Herrmann, Ken
    Herrmann, K.
    Krause, B. J.
    Schoenberg, S. O.
    Umutlu, L.
    Anton, F.
    Antoch, G.
    Hacker, M.
    Krause, B. J.
    Luster, M.
    Neumann, S.
    Schoenberg, S. O.
    Vorwerk, D.
    Schoenberg, Stefan
    Vorwerk, Dierk
    Antoch, Gerald
    Anton, Frank
    Neumann, Stefan
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2019, 191 (04): : 289 - 297
  • [9] Whole-Body [18F]-FDG-PET/MRI for Oncology: A Consensus Recommendation
    Umutlu, Lale
    Beyer, Thomas
    Grueneisen, Johannes Stefan
    Rischpler, Christoph
    Quick, Harald H.
    Veit-Halbach, Patrick
    Eiber, Matthias
    Purz, Sandra
    Antoch, Gerald
    Gatidis, Sergios
    Nikolaou, Konstantin
    Schaefer, Jurgen F.
    Rausch, Ivo
    Herrmann, Ken
    Herrmann, K.
    Krause, B. J.
    Schoenberg, S. O.
    Umutlu, L.
    Anton, F.
    Antoch, G.
    Hacker, M.
    Krause, B. J.
    Luster, M.
    Neumann, S.
    Schoenberg, S. O.
    Vorwerk, D.
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2019, 58 (02): : 68 - 76
  • [10] Detection and differentiation ability of quick whole-body FDG PET/MRI scan in oncology using a combination of Bayesian penalized likelihood PET reconstruction and abbreviated whole-body MRI
    Inukai, Junko
    Nogami, Munenobu
    Zeng, Feibi
    Kono, Atsushi
    Kubo, Kazuhiro
    Murakami, Takamichi
    JOURNAL OF NUCLEAR MEDICINE, 2021, 62