An EMG Feedback Control Functional Electrical Stimulation Cycling System

被引:0
|
作者
Chien-Chih Chen
Zong-Cian He
Ya-Hsin Hsueh
机构
[1] National Cheng-Kung University,Institute of Biomedical Engineering
[2] Kaohsiung Medical University,Department of Physical Therapy
[3] National Yunlin University of Science and Technology,Department and Institute of Electronic Engineering
[4] National Yunlin University of Science and Technology,Department and Institute of Electronic Engineering
来源
关键词
Functional electrical stimulation cycling system; EMG feedback control;
D O I
暂无
中图分类号
学科分类号
摘要
The prevalence of stroke and its residual disability is getting higher and higher in the whole world population. The functional electrical stimulation cycling system (FES-CS) is useful for hemiplegic patients to make the muscles of stroke patients be under hybrid activation. The raw electromyography (EMG) takes down the residual muscle force of stroke subjects; and the peak-to-peak of stimulus EMG indicates the force enhancement benefiting from electrical stimulation. This research proposed an EMG feedback control protocol of FES-CS, which includes a physiological signal recorder, a FPGA control module, DAC and electrical stimulation circuits. Using the strength of real-time EMG signal obtained from patients as a feedback to control the stimulation output intensity of FES cycling system.
引用
收藏
页码:195 / 203
页数:8
相关论文
共 50 条
  • [1] An EMG Feedback Control Functional Electrical Stimulation Cycling System
    Chen, Chien-Chih
    He, Zong-Cian
    Hsueh, Ya-Hsin
    JOURNAL OF SIGNAL PROCESSING SYSTEMS FOR SIGNAL IMAGE AND VIDEO TECHNOLOGY, 2011, 64 (02): : 195 - 203
  • [2] Modeling and control of functional electrical stimulation cycling training system
    Mingxu Sun
    Fangyuan Cheng
    Tingting Wang
    Chuan Hu
    Sizhong Wang
    Xiangyang Li
    Yuan Xu
    Min Liu
    Scientific Reports, 15 (1)
  • [3] Cadence control system for paediatric functional electrical stimulation cycling
    Pennycott, A.
    Hunt, K. J.
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2010, 5 (03) : 237 - 242
  • [4] Dual Neural Network Control of a Hybrid Functional Electrical Stimulation Cycling System
    Merritt, Glen R.
    Akbari, Saiedeh
    Cousin, Christian A.
    Yoon, Hwan-Sik
    JOURNAL OF DYNAMIC SYSTEMS MEASUREMENT AND CONTROL-TRANSACTIONS OF THE ASME, 2023, 145 (12):
  • [5] Stationary Cycling Induced by Switched Functional Electrical Stimulation Control
    Bellman, M. J.
    Cheng, T. -H.
    Downey, R. J.
    Dixon, W. E.
    2014 AMERICAN CONTROL CONFERENCE (ACC), 2014, : 4802 - 4809
  • [6] CYCLING INDUCED BY FUNCTIONAL ELECTRICAL STIMULATION: A CONTROL SYSTEMS PERSPECTIVE
    Dixon, Warren
    Bellman, Matthew
    MECHANICAL ENGINEERING, 2016, 138 (09)
  • [7] Amplifier design for EMG recording from stimulation electrodes during functional electrical stimulation leg cycling ergometry
    Shalaby, Raafat
    Schauer, Thomas
    Liedecke, Wolfgang
    Raisch, Joerg
    BIOMEDIZINISCHE TECHNIK, 2011, 56 (01): : 23 - 33
  • [8] Development of a Novel Functional Electrical Stimulation System for Hand Rehabilitation Using Feedback Control
    Ruppel, Mirjana
    Seel, Thomas
    Dogramadzi, Sanja
    2016 6TH IEEE INTERNATIONAL CONFERENCE ON BIOMEDICAL ROBOTICS AND BIOMECHATRONICS (BIOROB), 2016, : 1135 - 1139
  • [9] Conditional feedback control of upper limb rehabilitation system based on functional electrical stimulation
    Wu Z.-L.
    Huo B.-Y.
    Qin Y.-H.
    Liu Y.-H.
    Li D.-H.
    Kongzhi Lilun Yu Yingyong/Control Theory and Applications, 2022, 39 (06): : 1079 - 1087
  • [10] Stereo vision based position measurement feedback for a functional electrical stimulation control system
    Chang, Samuel
    Fuller, Joe
    Farsaie, Ali
    ISTM/2007: 7TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-7, CONFERENCE PROCEEDINGS, 2007, : 5179 - 5186