Near-wake measurement in a rotor/stator axial compressor using slanted hot-wire technique

被引:0
|
作者
S. T. Hsu
A. M. Wo
机构
[1] Institute of Applied Mechanics,
[2] National Taiwan University,undefined
[3] Taipei 106,undefined
[4] Taiwan,undefined
[5] Republic of China,undefined
来源
Experiments in Fluids | 1997年 / 23卷
关键词
Time Variation; Component Velocity; Pitch Angle; Axial Compressor; Unsteady Flow;
D O I
暂无
中图分类号
学科分类号
摘要
 Three-dimensional near-wake structure behind a rotor was measured using slanted hot-wire technique in a large-scale, low-speed, rotor/stator axial compressor. Unsteady flow interaction between blade rows was varied by setting the axial gap between rows at 10% and 30% of rotor chord. Results show that stronger flow interactions between blade rows, or closer axial gap, produce more pronounced time variation within the rotor wake. All parameters measured – three component velocities, yaw and pitch angles – varied strongly within the wake, and are quantified.