Non-contact measurement of elastic modulus by using laser ultrasound

被引:1
|
作者
Jongbeom Kim
Kyoung-Young Jhang
机构
[1] Hanyang University,Department of Mechanical convergence Engineering
[2] Hanyang University,School of Mechanical Engineering
关键词
Elastic modulus; Laser ultrasound; Non-contact; Non-destructive;
D O I
暂无
中图分类号
学科分类号
摘要
Non-contact measurement of elastic modulus is necessary for the in-line assessment of material in harsh environments such as high temperature. In this paper, a fully non-contact method to measure elastic modulus is proposed based on the laser ultrasonic technique (LUT) that uses a short-pulsed laser to generate ultrasound and the other laser coupled to an interferometer using a photorefractive crystal to detect the ultrasonic wave displacement. Basically, this method measures velocities of shear wave and longitudinal wave to obtain the elastic modulus. The uniqueness is that the velocity of shear wave is measured in the thermo-elastic regime first and then the velocity of longitudinal wave is measured in the ablation regime. This is because the strong mode of generated ultrasound is the shear wave in the thermo-elastic regime while the longitudinal wave in the ablation regime. Regime change can be achieved simply by switching the laser power, with no change in the measurement setup. In order to demonstrate the usefulness of the proposed method, the elastic modulus of aluminum casting alloy has been measured and the results were compared with a conventional contact method and a destructive tensile test. They showed good agreement with each other, which verified the usefulness of the proposed noncontact elastic modulus measurement method.
引用
收藏
页码:905 / 909
页数:4
相关论文
共 50 条
  • [1] Non-contact measurement of elastic modulus by using laser ultrasound
    Kim, Jongbeom
    Jhang, Kyoung-Young
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2015, 16 (05) : 905 - 909
  • [2] Elastic modulus of thermally treated fine grained sandstone using non-contact laser extensometer
    Sirdesai, N. N.
    Mahanta, Bankim
    Singh, T. N.
    Ranjith, P. G.
    PROCEEDINGS OF THE CONFERENCE ON RECENT ADVANCES IN ROCK ENGINEERING (RARE 2016), 2016, 91 : 105 - 109
  • [3] NON-CONTACT LASER MEASUREMENT DEVICE
    Vlk, Lukas
    XXIV. MEDZINARODNA KONFERENCIA SUCASNE PROBLEMY V KOLAJAVYCH VOZIDLACH, DIEL II, 2019, : 329 - 336
  • [4] Laser-optical non-contact measurement of pendular displacement of elastic device
    Zou, LM
    Yang, WG
    Jin, GL
    Tan, JB
    PROCEEDINGS OF THE THIRD INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY, VOL 2, 2004, : 772 - 777
  • [5] Non-contact measurement of ocular microtremor using laser speckle
    Kenny, E.
    Coakley, D.
    Boyle, G.
    BIOPHOTONICS: PHOTONIC SOLUTIONS FOR BETTER HEALTH CARE II, 2010, 7715
  • [6] A non-contact laser probe in industrial measurement
    Li, Y
    Zhang, LX
    Zhang, SL
    Han, YM
    1999 INTERNATIONAL CONFERENCE ON INDUSTRIAL LASERS (IL'99), 1999, 3862 : 306 - 310
  • [7] Non-contact temperature measurement by laser technology
    Huang, Fang
    Liu, Xiangxin
    Han, Junfeng
    Wang, Jing
    Li, Hui
    Wang, Wenjing
    Zhenkong Kexue yu Jishu Xuebao/Journal of Vacuum Science and Technology, 2013, 33 (07): : 642 - 646
  • [8] Non-contact measurement of facial actions using laser Doppler vibrometry
    Rohrbaugh, J. W.
    Sirevaag, E. J.
    INTERNATIONAL JOURNAL OF PSYCHOPHYSIOLOGY, 2012, 85 (03) : 312 - 312
  • [9] Non-contact surface roughness measurement using laser speckle technique
    Patel, Dhiren R.
    Kiran, M. B.
    2020 11TH INTERNATIONAL CONFERENCE ON MECHATRONICS AND MANUFACTURING (ICMM 2020), 2020, 895
  • [10] Non-contact laser/EMAT measurement systems for ultrasound B-scan imaging
    Dewhurst, RJ
    Murray, PR
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 21A & B, 2002, 615 : 348 - 355