Acute kidney injury detection using refined and physiological-feature augmented urine output

被引:0
|
作者
Sahar Alkhairy
Leo A. Celi
Mengling Feng
Andrew J. Zimolzak
机构
[1] Massachusetts Institute of Technology,Saw Swee Hock School of Public Health, National University Health System
[2] Beth Israel Deaconess Medical Center,undefined
[3] National University of Singapore,undefined
[4] Baylor College of Medicine,undefined
[5] Michael E. DeBakey VA Medical Center,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Acute kidney injury (AKI) is common in the intensive care unit, where it is associated with increased mortality. AKI is often defined using creatinine and urine output criteria. The creatinine-based definition is more reliable but less expedient, whereas the urine output based definition is rapid but less reliable. Our goal is to examine the urine output criterion and augment it with physiological features for better agreement with creatinine-based definitions of AKI. The objectives are threefold: (1) to characterize the baseline agreement of urine output and creatinine definitions of AKI; (2) to refine the urine output criteria to identify the thresholds that best agree with the creatinine-based definition; and (3) to build generalized estimating equation (GEE) and generalized linear mixed-effects (GLME) models with static and time-varying features to improve the accuracy of a near-real-time marker for AKI. We performed a retrospective observational study using data from two independent critical care databases, MIMIC-III and eICU, for critically ill patients who developed AKI in intensive care units. We found that the conventional urine output criterion (6 hr, 0.5 ml/kg/h) has specificity and sensitivity of 0.49 and 0.54 for MIMIC-III database; and specificity and sensitivity of 0.38 and 0.56 for eICU. Secondly, urine output thresholds of 12 hours and 0.6 ml/kg/h have specificity and sensitivity of 0.58 and 0.48 for MIMIC-III; and urine output thresholds of 10 hours and 0.6 ml/kg/h have specificity and sensitivity of 0.49 and 0.48 for eICU. Thirdly, the GEE model of four hours duration augmented with static and time-varying features can achieve a specificity and sensitivity of 0.66 and 0.61 for MIMIC-III; and specificity and sensitivity of 0.66 and 0.64 for eICU. The GLME model of four hours duration augmented with static and time-varying features can achieve a specificity and sensitivity of 0.71 and 0.55 for MIMIC-III; and specificity and sensitivity of 0.66 and 0.60 for eICU. The GEE model has greater performance than the GLME model, however, the GLME model is more reflective of the variables as fixed effects or random effects. The significant improvement in performance, relative to current definitions, when augmenting with patient features, suggest the need of incorporating these features when detecting disease onset and modeling at window-level rather than patient-level.
引用
收藏
相关论文
共 50 条
  • [1] Acute kidney injury detection using refined and physiological-feature augmented urine output (vol 11, 19561, 2021)
    Alkhairy, Sahar
    Celi, Leo A.
    Feng, Mengling
    Zimolzak, Andrew J.
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [2] Structural, physiological or clinical outcomes to define urine output threshold in acute kidney injury
    Machado, Guido Dias
    Santos, Leticia Liborio
    Liborio, Alexandre Braga
    CRITICAL CARE, 2024, 28 (01)
  • [3] The urine output definition of acute kidney injury is too liberal
    Ralib, Azrina Md
    Pickering, John W.
    Shaw, Geoffrey M.
    Endre, Zoltan H.
    CRITICAL CARE, 2013, 17 (03):
  • [4] The urine output definition of acute kidney injury is too liberal
    Azrina Md Ralib
    John W Pickering
    Geoffrey M Shaw
    Zoltán H Endre
    Critical Care, 17
  • [5] Continuous Real-Time Urine Output Monitoring for Early Detection of Acute Kidney Injury
    Panagiotou, Anthi
    Garzotto, Francesco
    Gramaticopolo, Silvia
    Piccinni, Pasquale
    Trentin, Chiara
    Cruz, Dinna N.
    Ronco, Claudio
    HEMODIALYSIS: NEW METHODS AND FUTURE TECHNOLOGY, 2011, 171 : 194 - 200
  • [6] Intensive Monitoring of Urine Output Is Associated With Increased Detection of Acute Kidney Injury and Improved Outcomes
    Jin, Kui
    Murugan, Raghavan
    Sileanu, Florentina E.
    Foldes, Emily
    Priyanka, Priyanka
    Clermont, Gilles
    Kellum, John A.
    CHEST, 2017, 152 (05) : 972 - 979
  • [7] Perioperative acute kidney injury and urine output in lower limb arthroplasties
    Nikkinen, Okke
    Jamsa, Elias
    Aaltonen, Toni
    Alahuhta, Seppo
    Ohtonen, Pasi
    Vakkala, Merja
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2021, 65 (08) : 1054 - 1064
  • [8] Additional role of urine output criterion in defining acute kidney injury
    Han, Seung Seok
    Kang, Kyung Ja
    Kwon, Soon Jung
    Wang, Su Jung
    Shin, Sun Hee
    Oh, Se-Won
    Na, Ki Young
    Chae, Dong-Wan
    Kim, Suhnggwon
    Chin, Ho Jun
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2012, 27 (01) : 161 - 165
  • [9] Urine output and acute kidney injury following laparoscopic pancreas operations
    Morales, Diana J. Valencia
    Plack, Daniel L.
    Kendrick, Michael L.
    Schroeder, Darrell R.
    Sprung, Juraj
    Weingarten, Toby N.
    HPB, 2022, 24 (11) : 1967 - 1974
  • [10] Acute Kidney Injury in Neonates: From Urine Output to New Biomarkers
    Liborio, Alexandre Braga
    Pereira Castello Branco, Klebia Magalhaes
    de Melo Bezerra, Candice Torres
    BIOMED RESEARCH INTERNATIONAL, 2014, 2014