Reliability of the method of levels for determining cutaneous temperature sensitivity

被引:0
|
作者
Miroljub Jakovljević
Igor B. Mekjavić
机构
[1] University of Ljubljana,Faculty of Health Studies
[2] Josef Stefan Institute,Department of Automation, Biocybernetics and Robotics
关键词
Thermotactile quantitative sensory testing; Healthy subjects; Reliability;
D O I
暂无
中图分类号
学科分类号
摘要
Determination of the thermal thresholds is used clinically for evaluation of peripheral nervous system function. The aim of this study was to evaluate reliability of the method of levels performed with a new, low cost device for determining cutaneous temperature sensitivity. Nineteen male subjects were included in the study. Thermal thresholds were tested on the right side at the volar surface of mid-forearm, lateral surface of mid-upper arm and front area of mid-thigh. Thermal testing was carried out by the method of levels with an initial temperature step of 2°C. Variability of thermal thresholds was expressed by means of the ratio between the second and the first testing, coefficient of variation (CV), coefficient of repeatability (CR), intraclass correlation coefficient (ICC), mean difference between sessions (S1-S2diff), standard error of measurement (SEM) and minimally detectable change (MDC). There were no statistically significant changes between sessions for warm or cold thresholds, or between warm and cold thresholds. Within-subject CVs were acceptable. The CR estimates for warm thresholds ranged from 0.74°C to 1.06°C and from 0.67°C to 1.07°C for cold thresholds. The ICC values for intra-rater reliability ranged from 0.41 to 0.72 for warm thresholds and from 0.67 to 0.84 for cold thresholds. S1-S2diff ranged from −0.15°C to 0.07°C for warm thresholds, and from −0.08°C to 0.07°C for cold thresholds. SEM ranged from 0.26°C to 0.38°C for warm thresholds, and from 0.23°C to 0.38°C for cold thresholds. Estimated MDC values were between 0.60°C and 0.88°C for warm thresholds, and 0.53°C and 0.88°C for cold thresholds. The method of levels for determining cutaneous temperature sensitivity has acceptable reliability.
引用
收藏
页码:811 / 821
页数:10
相关论文
共 50 条
  • [1] Reliability of the method of levels for determining cutaneous temperature sensitivity
    Jakovljevic, Miroljub
    Mekjavic, Igor B.
    [J]. INTERNATIONAL JOURNAL OF BIOMETEOROLOGY, 2012, 56 (05) : 811 - 821
  • [2] Analysis of the effect of temperature on the reliability of determining the insulation state of transformers by the FDS method
    Gutten, M.
    Korenciak, D.
    [J]. 2023 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, CEIDP, 2023,
  • [3] Reliability sensitivity by method of moments
    Lu, Zhenzhou
    Song, Jun
    Song, Shufang
    Yue, Zhufeng
    Wang, Jian
    [J]. APPLIED MATHEMATICAL MODELLING, 2010, 34 (10) : 2860 - 2871
  • [4] A METHOD FOR DETERMINING CLINICAL ALGORITHM RELIABILITY
    MARGOLIS, CZ
    PEARSON, S
    GOTTLIEB, LK
    DAVIS, S
    KUVIN, SL
    PLISKIN, J
    [J]. MEDICAL DECISION MAKING, 1990, 10 (04) : 329 - 329
  • [5] STClass: A Method for Determining the Sensitivity of Documents
    Morales Escobar, Saturnino Job
    Ruiz Shulcloper, Jose
    Juarez Landin, Cristina
    Ruiz-Castilla, Jose-Sergio
    Perez Garcia, Osvaldo Andres
    [J]. ADVANCES IN SOFT COMPUTING (MICAI 2021), PT II, 2021, 13068 : 140 - 152
  • [6] A METHOD FOR DETERMINING SENSITIVITY TO PENICILLIN AND STREPTOMYCIN
    HOYT, RE
    LEVINE, MG
    [J]. SCIENCE, 1947, 106 (2747) : 171 - 171
  • [7] BODY TEMPERATURE AND CUTANEOUS SENSITIVITY TO TINGLING AND PAIN
    KLEITMAN, N
    RAMSAROOP, A
    [J]. FEDERATION PROCEEDINGS, 1946, 5 (01) : 56 - 56
  • [8] Reliability sensitivity method by line sampling
    Lu, Zhenzhou
    Song, Shufang
    Yue, Zhufeng
    Wang, Jian
    [J]. STRUCTURAL SAFETY, 2008, 30 (06) : 517 - 532
  • [10] HEURISTIC METHOD FOR DETERMINING OPTIMAL RELIABILITY ALLOCATION
    NAKAGAWA, Y
    NAKASHIMA, K
    [J]. IEEE TRANSACTIONS ON RELIABILITY, 1977, 26 (03) : 156 - 161