Effect of X-Ray Tube Focal Spot Size on Radiovisiograph Resolution

被引:0
|
作者
Blinov N.N. [1 ]
Vasilyev A.Y. [2 ]
Bessonov V.B. [3 ]
Gryaznov A.Y. [3 ]
Zhamova K.K. [3 ]
Potrakhov E.N. [3 ]
Potrakhov N.N. [3 ]
机构
[1] Amico JSC, Moscow
[2] Moscow State Medico-Stomatological University, Moscow
[3] St. Petersburg State Electrotechnical University, St. Petersburg
来源
Blinov, N. N. (nblinov@amico.ru) | 1600年 / Springer Science and Business Media, LLC卷 / 48期
关键词
Focal Spot; Test Pattern; Line Pair; Image Sharpness; Focal Spot Size;
D O I
10.1007/s10527-014-9418-1
中图分类号
O572 [高能物理学];
学科分类号
摘要
The effect of the X-ray tube focal spot size on radiovisiograph resolution was tested experimentally. © 2014 Springer Science+Business Media New York.
引用
收藏
页码:58 / 61
页数:3
相关论文
共 50 条
  • [1] AN INVESTIGATION OF THE FOCAL SPOT SIZE IN A MICROFOCUS X-RAY TUBE
    GRIDER, DE
    AUSBURN, PK
    BRITISH JOURNAL OF NON-DESTRUCTIVE TESTING, 1987, 29 (01): : 15 - 17
  • [2] The effect of focal spot size on the spatial resolution of variable resolution X-ray CT scanner
    Arabi, H.
    Asl, A. R. Kamali
    Aghamiri, S. M.
    IRANIAN JOURNAL OF RADIATION RESEARCH, 2010, 8 (01): : 37 - 43
  • [3] Effect of electrode configurations on the focal spot of x-ray tube
    Guo Jinchuan
    Ren Xikui
    Zhou Bin
    Niu Hanben
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS IV, 2010, 7845
  • [4] X-ray tube focal spot size, digital detectors, imaging system aperture and spatial resolution
    Nickoloff, Edward L.
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [5] Research on Cylinder Method for Measuring Focal Spot Size of X-ray Tube
    Li W.
    Wang L.
    Zheng J.
    Xu S.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2022, 56 (10): : 2155 - 2164
  • [6] Research on Slit Method for Measuring Focal Spot Size of X-ray Tube
    Li W.
    Wang L.
    Zheng J.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2024, 58 (02): : 498 - 505
  • [7] DETERMINATION OF X-RAY TUBE FOCAL SPOT POSITION
    KUBOTA, H
    OZAKI, Y
    MATSUMOTO, M
    KANAMORI, H
    MEDICAL PHYSICS, 1993, 20 (04) : 1029 - 1031
  • [8] X-RAY TUBE FOCAL SPOT SIZES - COMPREHENSIVE STUDIES OF THEIR MEASUREMENT AND EFFECT OF MEASURED SIZE IN ANGIOGRAPHY
    DOI, K
    LOO, LN
    CHAN, HP
    RADIOLOGY, 1982, 144 (02) : 383 - 393
  • [9] The determination of the focal spot size of an X-ray tube from the radiation beam profile
    Oliveira, A. D.
    Fartaria, M. J.
    Cardoso, J.
    Santos, L. M.
    Oliveira, C.
    Pereira, M. F.
    Alves, J. G.
    RADIATION MEASUREMENTS, 2015, 82 : 138 - 145
  • [10] MANUFACTURERS DESIGNATION OF DIAGNOSTIC X-RAY TUBE FOCAL SPOT SIZE - TIME FOR CANDOR
    BERGERON, RT
    RADIOLOGY, 1974, 111 (02) : 487 - 488